Atlas IED AP-S15IP User Manual

15A IP LAN Controlled AC Power Distibution & Conditioner with Local & Remote Monitoring
Features
• 15A Rack Mount Power Conditioner with LAN Network
Monitoring & Control
• On-board IP Address Display
• IP Discovery PC Software
• Circuit Breaker Protection @ 15A
• 9 Total AC Outlets
• 8 Rear Panel Programmable Switched Outlets
• 1 Front Panel Unswitched Convenience Outlet
• Individual Outlet On / Off Manual Switch and LED Indicator
(Enable / Disable)
• Removable 15A IEC Power Cord with Retainer Bracket
• AC Mains RFI Noise Filtering & Surge Protection
• Earth Ground Fault Connection Indicator
• Web User Interface
• DHCP or Static IP Addressable
• Voltage, Current, Temperature and Humidity Monitoring Capability
• Over Voltage, Current, Temperature and Humidity Alarm Setting
• Each Outlet Can be Individually Managed Remotely
• User Definable Names for Each Outlet
• User Definable Delay Time and Sequence
• Temperature Setting for AC Fan Activation
• Fault Log with Reporting
• Fault Reporting GPIO Port
• Password Protection
• Individual Outlet Auto Ping Reset
• User Definable 24 / 7 Schedules of Individual Outlets to Switch
Devices On or Off
• 3-Meter Humidity / Temperature Probe
• AP-LEDIP Display Panel Shows Voltage, Current, Temperature,
Humidity and IP Address
Applications
The flexible AP-S15IP was designed with features to be used in a variety of applications. It can be used for AC distribution or for system power and protection against voltage surges or dropouts. The AP-S15IP is ideal for systems that need to be powered On or Off at specific times to conserve energy or to monitor the system for faults and operability. The AP-S15IP can also be used for power conditioning and surge protection. The following are examples of applications where the AP-S15IP can be used:
• Office Buildings
• Restaurants
• Houses of Worship
• Educational Facilities
• Theaters
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
• Industrial Applications
General Description
The AP-S15IP is a power conditioner with LAN monitoring & remote control for AC power distribution management. The AP-S15IP features a local display and a web based user interface (UI) that can monitor voltage, current, temperature and humidity. Through the UI, alarms can be set to alert users when a fault condition has occurred via the network UI or Fault contacts. The AP-S15IP’s eight rear outlets are programmable and can be scheduled to sequence On / Off individually or in groups on a 24-hour / 7-day schedule. Each AC outlet has a front panel LED status indicator can also be used to manually turn the outlet On or Off. This feature can be disabled via the UI for increased security. A front panel unswitched AC outlet is also included.
The AP-S15IP utilizes the AP-LEDIP remote display to visually show the system's AC power and environmental status, as well as the unit's assigned IP address. The AP-LEDIP can be placed within 10ft of the AP-S15IP. There is also an IP discovery software to help identify AtlasIED IP power strips connected to the network. The AP-LEDIP also provides a visual reference of the voltage, current, temperature or humidity data within the rack in real time. The external temperature / humidity probe monitors rack climate conditions to activate a cooling system if needed. Programmable alarm settings are easily configured with fault logs and fault reporting via the UI. The unit or individual outlets can be tested or monitored for on active status via the network Auto Ping Reset feature.
The AP-S15IP features noise filtering for unwanted Radio Frequency Interference (RFI) that is commonly introduced into AC lines by nearby radio transmitters or wireless products that commonly deteriorate video signals and that can be heard as static in audio signals. Unstable AC Mains voltage is one of the main reasons for equipment failure. The amount of energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A. These spikes are very fast and usually only last for a very short period of time. The AP-S15IP's circuitry is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds, thus ensuring virtually trouble-free protection. If damage to the suppression circuitry occurs, the AC fault LED will illuminate. The AP-S15IP is designed to allow the installer to select the power cord length that is required for the installation. A removable 2m, 14-gauge IEC power cord with a retainer bracket is supplied with the unit.
The AP-S15IP is designed to be rack mounted into full width racks using 19" (1RU) space.
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
System
Type Networked AC Power Distribution Conditioner & Suppressor
Load Rating Max Load 15A (1800W), Rated Load 12A (1440W)
Network Type LAN (Local Area Network) (Note 1)
Front Panel
Activation Switch Rocker with Security Bar
Circuit Breaker 15A Resettable Power Switch
Outlet On / Off Switches Momentary Manual
AC Outlets NEMA5-15R Unswitched, Qty 1
Front Panel Indicators
Power On Indicator Power Switch LED, Red
Outlet Status Indicators Green, Qty 8
Over Temperature Alarm Indicator Red, Programmable Range 50° - 176°F , 10° - 80°C
Over Humidity Alarm Indicator Red, Programmable Range 15 - 95%
Over Current / Voltage Alarm Indicator Red, Programmable Range High - Voltage 100V - 140V, Under Voltage 80V- 120V
AC Fault Indicator Red, Illuminates When Surge Protection is Damaged
AC Ground Indicator Red, Illuminates When Earth Ground Is Bad
Rear Panel
AC Outlets NEMA5-15R Switched (Programmable), Qty 8
AC Mains IEC Power Socket IEC NEMA 5-15P 15A 1800W with Power Cord Retainer
LAN Port RJ45, Ethernet Port
Temp / Humidity Port RJ14, Temperature, Humidity Probe, 2M, Probe Included
Display Port RJ25, for AP-LEDIP Display for Voltage, Current, Temperature, Humidity, IP Address
Fault Report Port 3.5mm Jack, Fault Reporting Contact Closure, Normally Closed & Opens During Fault State, Cable Included
GPIO Fault Relay Port Fault Relay Interface, Temperature, Humidity, Over & Under Voltage, Over Current, Surge, Cable Included
User Interface and Configuration
WEB Interface HTTP Protocol, XML Commands Available
Status Voltage, Current, Temperature, Humidity, Spike Protection, Ground Fault, Outlet Status
Alarms Voltage Hi / Lo, Current, System Temperature, Humidity, Fault Log
Scheduler 24 / 7, Group Schedule or Individual Outlet Schedule
Network Settings DHCP (default) or Static IP, Individual Outlet Auto Ping Reset (Note 1)
System Configuration Outlet Naming, Group Assignment, Sequence Delay Timing, Temperature Activated Outlet
Technical Data
Max AC Mains Current 12A, 1440W
Operating Voltage 100VAC - 132VAC
Power Consumption 8-Watts
Noise Attenuation RFI 10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz
Min. Spike Clamping Voltage 460VRMS @ 3,000A
Max. Spike Clamping Voltage 6000V, 1 nanosecond
Spike Clamping Voltage @ 100A 1250Vp for 20µs
Maximum Surge Current 6,500A
Energy Rating @ 2ms 600 Joules
Unit Operating Temperature Range 40º - 105ºF, 5º - 40.5ºC
Humidity Range 5% to 95% Relative Humidity
Fault Reporting WEB, GPIO Contact Closure (Closed During Normal Operation, Opens During Fault Condition), API Commands
Note: Outlet 8 Can Be Used to Activate a Fan Triggered by Temperature Range of On: 51° - 176°F / Off: 50° - 175°F
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
Mechanical
Chassis Finish Black
Product Dimensions (HxWxD) 1.75" x 19" x 7.35" (45mm x 481mm x 187mm)
Shipping Dimensions (HxWxD) 5" x 18.7" x 10.6" (129mm x 475mm x 269mm)
Unit Weight 5.5 lbs. (2.5kg)
Shipping Weight 7.72 lbs. (3.5kg)
Package Contents AP-S15IP, Temperature / Humidity Probe, Fault Interface Probe, 2m 14-Gauge IED Power Cord,
Agency Approvals
Safety Listing North America UL1449, UL60950-1, CAN/CSA C22.2 No. 60950-1
IEC Power Cord Retailer Bracket, AP-LEDIP Display, Qty 1 Each
Note 1: The AP-S15IP meets the Californian law SB-327. Each unit is shipped with a unique password that can be changed for accessing the device over the network. The AP-S15IP is a LAN (Local Area Network) device and requires a firewall or VPN for secure outside the network operation. AtlasIED recommends consulting an IT specialist for best network security practices before installation.
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
AP-S15IP System Diagram Example
Progr amme d for Fan using
Temp Probe
AtlasIED EFP3-2
Dual Fan Rack Mount
EQUI PMEN T RACK
WIRE LESS MI C
RECEI VER
SOURC E MEDI A
PLAYER
SIGNAL PROCESSOR
Outle ts 2 thru 7 - Group S equenced Programmed
EQUI PMEN T RACK
POWER AMP-1
POWER AMP-2
POWER AMP-3
Temperature ProbeTemperature Probe
Contr ol System
Progr ammed
for Always
ON
Fault Report connected to
Texas Toug h Rack wil l
Change Logo Color w hen
Fault is detected
Local Lan
Local Lan
Router
Router
AP-LEDIP
Included Display
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
Dimensional Drawings
1.75"
(45mm)
7.35"
(186.7mm)
OC/OV
OH
OT
1601 Jack McKay Blvd. • Ennis, TX 75119
800.876.3333 • AtlasIED.com
WARNING: SHOCK HAZARD - DO NOT OPEN
AVIS: RISQUE DE CHOC ELÉCTRIQUE - NE PAS OUVRIR
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
AVIS: NE PAS EXPOSER CE MATÉRIEL À LA PLUIE OU L’HUMIDITE
AFIN DE REDUIRE LE RISQUE D’INFLAMMATION OU DE CHOC ELÉCTRIQUE
I.T.E.
E467418
Made in Taiwan
5678
1234
AP-S15IP
IP Addressable Power Distribution Unit
Model: AP-S15IP Input: 125Vac 50/60Hz 12A Output: 125Vac 50/60Hz 12A 1500W Maximum
Caution: The socket-outlet shall be installed near the equipment and shall be easily accessible.ID: T
19"
(480.8mm)
UnswitchedAlarms
AC FaultAC Ground
12345678 / Fan
Report
Reset
Off
LANDisplaySensorFault
6"
(153.2mm)
17"
(432mm)
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
AP-LEDIP
This remote magnetic data display comes with a 10ft cable so it can be placed on the rack where data viewing is preferred. This display can show AC mains voltage, current, rack temperature and humidity. The preferred data value to be shown can be set in the WEB interface. The other readings can be accessed by pressing the data display viewing switch located on the front of the display. One of the main features is the display of the IP address assigned to the power strip. Press and hold the data display viewing button and the assigned IP address will scroll.
Magnetic display can be placed outside of the door when closed.
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
Architect and Engineer Specications
The AtlasIED power conditioner and surge protector with LAN monitoring & remote control shall be AtlasIED model AP-S15IP. The AP-S15IP shall provide up to 1440-Watts of 120V AC power to a total of 9 AC outlets: 8 rear programmable panel outlets and 1 front panel unswitched outlet.
The AP-S15IP shall have a web based user interface (UI). Each unit shall ship with a unique password for accessing a network to comply with the California law SB-327. The AP-S15IP shall monitor voltage, current, plus temperature and humidity via an external probe. The AP-S15IP shall have alarms set to alert users when a fault condition has occurred via the network UI or via the rear fault contacts. The AP-S15IP shall have the ability to program a scheduler to sequence outlet activation as a group or individually.
The AP-S15IP shall utilize PC based IP discovery software to identify a unit IP address within a LAN. The assigned IP address is also shown via the included AP-LEDIP remote display. Voltage, current, temperature or humidity shall be monitored via the UI. The external temperature / humidity probe shall measure the rack climate conditions to activate a cooling system if needed. Each outlet shall be tested or monitored for active status via a network Auto Ping Reset feature.
The AP-S15IP shall feature noise filtering for unwanted Radio Frequency Interference (RFI). The unit shall have circuit breaker protection at 15A. The AP-S15IP front panel shall include AC Ground, AC Fault and Outlets Active indicators and protective security bar over power switch. Finish shall be textured black epoxy and dimensions shall be
1.75"H x 19"W x 7.35"D (45mm x 481mm x 187mm) to mount into 1RU of space. The AP-S15IP shall come with removable rack ears.
The AP-S15IP complies with UL1449, UL60950-1 and CAN/CSA C22.2 No. 60950-1.
The AtlasIED power conditioner with LAN monitoring & remote control shall be the AP-S15IP.
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333 SUPPORT@ATLASIED.COM
AtlasIED.com
Loading...