AP-S15IP
15A IP LAN Controlled AC Power Distibution & Conditioner with Local & Remote Monitoring
Features
• 15A Rack Mount Power Conditioner with LAN Network
Monitoring & Control
• On-board IP Address Display
• IP Discovery PC Software
• Circuit Breaker Protection @ 15A
• 9 Total AC Outlets
• 8 Rear Panel Programmable Switched Outlets
• 1 Front Panel Unswitched Convenience Outlet
• Individual Outlet On / Off Manual Switch and LED Indicator
(Enable / Disable)
• Removable 15A IEC Power Cord with Retainer Bracket
• AC Mains RFI Noise Filtering & Surge Protection
• Earth Ground Fault Connection Indicator
• Web User Interface
• DHCP or Static IP Addressable
• Voltage, Current, Temperature and Humidity Monitoring Capability
• Over Voltage, Current, Temperature and Humidity Alarm Setting
• Each Outlet Can be Individually Managed Remotely
• User Definable Names for Each Outlet
• User Definable Delay Time and Sequence
• Temperature Setting for AC Fan Activation
• Fault Log with Reporting
• Fault Reporting GPIO Port
• Password Protection
• Individual Outlet Auto Ping Reset
• User Definable 24 / 7 Schedules of Individual Outlets to Switch
Devices On or Off
• 3-Meter Humidity / Temperature Probe
• AP-LEDIP Display Panel Shows Voltage, Current, Temperature,
Humidity and IP Address
Applications
The flexible AP-S15IP was designed with features to be used in a variety
of applications. It can be used for AC distribution or for system power and
protection against voltage surges or dropouts. The AP-S15IP is ideal for
systems that need to be powered On or Off at specific times to conserve
energy or to monitor the system for faults and operability. The AP-S15IP
can also be used for power conditioning and surge protection. The
following are examples of applications where the AP-S15IP can be used:
• Office Buildings
• Restaurants
• Houses of Worship
• Educational Facilities
• Theaters
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
• Industrial Applications
General Description
The AP-S15IP is a power conditioner with LAN monitoring & remote
control for AC power distribution management. The AP-S15IP features
a local display and a web based user interface (UI) that can monitor
voltage, current, temperature and humidity. Through the UI, alarms can
be set to alert users when a fault condition has occurred via the network
UI or Fault contacts. The AP-S15IP’s eight rear outlets are programmable
and can be scheduled to sequence On / Off individually or in groups on a
24-hour / 7-day schedule. Each AC outlet has a front panel LED status
indicator can also be used to manually turn the outlet On or Off. This
feature can be disabled via the UI for increased security. A front panel
unswitched AC outlet is also included.
The AP-S15IP utilizes the AP-LEDIP remote display to visually show
the system's AC power and environmental status, as well as the unit's
assigned IP address. The AP-LEDIP can be placed within 10ft of the
AP-S15IP. There is also an IP discovery software to help identify AtlasIED
IP power strips connected to the network. The AP-LEDIP also provides
a visual reference of the voltage, current, temperature or humidity data
within the rack in real time. The external temperature / humidity probe
monitors rack climate conditions to activate a cooling system if needed.
Programmable alarm settings are easily configured with fault logs and
fault reporting via the UI. The unit or individual outlets can be tested or
monitored for on active status via the network Auto Ping Reset feature.
The AP-S15IP features noise filtering for unwanted Radio Frequency
Interference (RFI) that is commonly introduced into AC lines by nearby
radio transmitters or wireless products that commonly deteriorate video
signals and that can be heard as static in audio signals. Unstable AC
Mains voltage is one of the main reasons for equipment failure. The
amount of energy that can be injected into the power system can be
immense with voltages reaching 6kV or amperage peaks of 3000A.
These spikes are very fast and usually only last for a very short period of
time. The AP-S15IP's circuitry is very fast and can suppress unwanted
energy within a nanosecond response and sustain the suppression up to
2 milliseconds, thus ensuring virtually trouble-free protection. If damage
to the suppression circuitry occurs, the AC fault LED will illuminate.
The AP-S15IP is designed to allow the installer to select the power cord
length that is required for the installation. A removable 2m, 14-gauge IEC
power cord with a retainer bracket is supplied with the unit.
The AP-S15IP is designed to be rack mounted into full width racks using
19" (1RU) space.
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
System
Type Networked AC Power Distribution Conditioner & Suppressor
Load Rating Max Load 15A (1800W), Rated Load 12A (1440W)
Network Type LAN (Local Area Network) (Note 1)
Front Panel
Activation Switch Rocker with Security Bar
Circuit Breaker 15A Resettable Power Switch
Outlet On / Off Switches Momentary Manual
AC Outlets NEMA5-15R Unswitched, Qty 1
Front Panel Indicators
Power On Indicator Power Switch LED, Red
Outlet Status Indicators Green, Qty 8
Over Temperature Alarm Indicator Red, Programmable Range 50° - 176°F , 10° - 80°C
Over Humidity Alarm Indicator Red, Programmable Range 15 - 95%
Over Current / Voltage Alarm Indicator Red, Programmable Range High - Voltage 100V - 140V, Under Voltage 80V- 120V
AC Fault Indicator Red, Illuminates When Surge Protection is Damaged
AC Ground Indicator Red, Illuminates When Earth Ground Is Bad
Rear Panel
AC Outlets NEMA5-15R Switched (Programmable), Qty 8
AC Mains IEC Power Socket IEC NEMA 5-15P 15A 1800W with Power Cord Retainer
LAN Port RJ45, Ethernet Port
Temp / Humidity Port RJ14, Temperature, Humidity Probe, 2M, Probe Included
Display Port RJ25, for AP-LEDIP Display for Voltage, Current, Temperature, Humidity, IP Address
Fault Report Port 3.5mm Jack, Fault Reporting Contact Closure, Normally Closed & Opens During Fault State, Cable Included
GPIO Fault Relay Port Fault Relay Interface, Temperature, Humidity, Over & Under Voltage, Over Current, Surge, Cable Included
User Interface and Configuration
WEB Interface HTTP Protocol, XML Commands Available
Status Voltage, Current, Temperature, Humidity, Spike Protection, Ground Fault, Outlet Status
Alarms Voltage Hi / Lo, Current, System Temperature, Humidity, Fault Log
Scheduler 24 / 7, Group Schedule or Individual Outlet Schedule
Network Settings DHCP (default) or Static IP, Individual Outlet Auto Ping Reset (Note 1)
System Configuration Outlet Naming, Group Assignment, Sequence Delay Timing, Temperature Activated Outlet
Technical Data
Max AC Mains Current 12A, 1440W
Operating Voltage 100VAC - 132VAC
Power Consumption 8-Watts
Noise Attenuation RFI 10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz
Min. Spike Clamping Voltage 460VRMS @ 3,000A
Max. Spike Clamping Voltage 6000V, 1 nanosecond
Spike Clamping Voltage @ 100A 1250Vp for 20µs
Maximum Surge Current 6,500A
Energy Rating @ 2ms 600 Joules
Unit Operating Temperature Range 40º - 105ºF, 5º - 40.5ºC
Humidity Range 5% to 95% Relative Humidity
Fault Reporting WEB, GPIO Contact Closure (Closed During Normal Operation, Opens During Fault Condition), API Commands
Note: Outlet 8 Can Be Used to Activate a Fan Triggered by Temperature Range of On: 51° - 176°F / Off: 50° - 175°F
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com
Mechanical
Chassis Finish Black
Product Dimensions (HxWxD) 1.75" x 19" x 7.35" (45mm x 481mm x 187mm)
Shipping Dimensions (HxWxD) 5" x 18.7" x 10.6" (129mm x 475mm x 269mm)
Unit Weight 5.5 lbs. (2.5kg)
Shipping Weight 7.72 lbs. (3.5kg)
Package Contents AP-S15IP, Temperature / Humidity Probe, Fault Interface Probe, 2m 14-Gauge IED Power Cord,
Agency Approvals
Safety Listing North America UL1449, UL60950-1, CAN/CSA C22.2 No. 60950-1
IEC Power Cord Retailer Bracket, AP-LEDIP Display, Qty 1 Each
Note 1: The AP-S15IP meets the Californian law SB-327. Each unit is shipped with a unique password that can be changed for accessing the device
over the network. The AP-S15IP is a LAN (Local Area Network) device and requires a firewall or VPN for secure outside the network operation. AtlasIED
recommends consulting an IT specialist for best network security practices before installation.
©2019 Atlas Sound LP. The Atlas “Circle A”, Soundolier, and Atlas Sound are trademarks of Atlas Sound L.P. IED is a Registered Trademark of Innovative Electronic Designs LLC. All rights reserved.
All other Trademarks are property of their respective owners. No endorsement is implied. Due to continual product development, specifications are subject to change without notice. ATS005990 RevD 12/19
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
AtlasIED.com