Atlas GUARDIAN PRO MLGS180B, GUARDIAN PRO MLGS180W User Manual

Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes require installation by a quali-
fied electrician.
240-029-A
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Models MLGS180B
MLGS180W
Mode: On-Time: Works: Day Night
Test 5 Sec x x Auto 1, 5, 10 min. x Manual Until Dawn* x
OPERATION
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes
for the circuitry to calibrate.
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
... back on.
1 Second OFF
then...
Put the ON-TIME switch in the 1, 5, or 10 minute position.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
Manual mode only works at night because daylight returns the sen­sor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
Move ON-TIME Switch to
1, 5, or 10 minutes
Mode Switching Summary
Flip light switch off
for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn
the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
TEST
AUTO
MANUAL MODE
GUARDIAN PRO
MOTION SENSOR
-2-
598-1096-01
Swing the sensor head towards the clamp
screw.
For eave mount only:
Controls
INSTALLATION
WIRE THE LIGHT CONTROL.
Turn power off at the fuse or circuit breaker.Remove the existing light fixture, if present.
These instructions show the sensor wired to flood­lamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched "hot" wire. The lighting load (Up to 500 Watts, 4.2A Maximum) is placed across the white and red wires.
After screwing the sensor into the wall plate,
connect the junction box wires to the Light Control wires by twisting together and securing with wire connectors.
MOUNT THE LIGHT.
Follow the instructions that came with your light
fixture for mounting and adjusting the light fixture.
Keep regular PAR-38 lamps at least 1" (25 mm)
from the sensor. Halogen lamps should be kept at least 2" (51 mm) from the sensor.
Black to Black
White to White
Red Sensor Wire to
Black Lamp Wire
Optional: Connect additional load across
the white and red wires. Total lighting load including lampheads on fixture must not exceed 500 Watts (4.2A).
Junction
Box
Lamp Holders
For under eave installation, the sensor head must be rotated as shown in the next two steps for
proper operation and to avoid the risk of electrical shock.
Rotate the sensor head clockwise 180° so the
controls face down.
Clamp Screw
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Loading...