Operating manual "1819- EN" - 35 -
Alféa Extensa / Excellia A.I. and Alféa Extensa / Excellia Duo A.I. heat pumps
Trade name / Product name:
Atlantic / Alféa Excellia Duo A.I.
11 14 tri 11 tri 14 tri 16
Export Code (with backup)
Export Code (without backup)
526355
526365
526356
526366
526357
526367
526358
526368
526359
526369
Heating applications 35°C 55°C 35°C 55°C 35°C 55°C 35°C 55°C 35°C 55°C
Acoustic data
Sound power level of hydraulic unit LWAdB (A) 46 46 46 46 46
Sound power level of outdoor unit LWAdB (A) 69 69 68 69 69
Declared heat output with a partial load for an indoor temperature of 20°C and an outdoor temperature of Tj
Tj = -7°C Pdh kW 10.0 8.2 11.1 10.0 10.0 8.2 11.1 10.0 12.0 11.5
Tj = +2°C Pdh kW 6.1 5.0 6.7 6.1 6.1 5.0 6.7 6.1 7.3 7.0
Tj = +7°C Pdh kW 6.2 5.9 6.2 5.9 6.2 5.9 6.2 5.9 6.3 5.8
Tj = +12°C Pdh kW 7.4 7.0 7.3 7.1 7.4 7.0 7.3 7.1 7.4 7.1
Tj = bivalent temperature Pdh kW 10.0 8.2 11.1 10.0 10.0 8.2 11.1 10.0 12.0 11.5
Tj = operating temperature limit Pdh kW 10.0 8.0 10.8 9.3 9.9 8.1 10.8 9.3 11.7 10.3
Bivalent temperature T
biv
°C -7 -7 -7 -7 -7 -7 -7 -7 -7 -7
Degradation coefcient
(3)
Cdh - 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
Declared coecients of performance with a partial load for an indoor temperature of 20°C and an outdoor temperature of Tj
Tj = -7°C COP
d
- 2.57 1.89 2.51 1.89 2.70 1.92 2.54 1.95 2.43 1.83
Tj = +2°C COP
d
- 3.65 2.80 3.60 2.77 3.70 2.75 3.70 2.87 3.62 2.89
Tj = +7°C COP
d
- 5.35 3.76 5.35 3.89 5.49 3.93 5.39 4.07 5.51 4.12
Tj = +12°C COP
d
- 6.90 4.81 6.90 5.11 7.09 5.16 7.04 5.38 7.16 5.50
Tj = bivalent temperature COP
d
- 2.57 1.89 2.51 1.89 2.70 1.92 2.54 1.95 2.43 1.83
Tj = operating temperature limit COP
d
- 2.24 1.66 2.38 1.67 2.29 1.61 2.40 1.64 2.28 1.63
For air/water heat pumps: operating
temperature limit
TOL °C -10 -10 -10 -10 -10 -10 -10 -10 -10 -10
Maximum heating water operating
temperature
WTOL °C 60 60 60 60 60 60 60 60 60 60
Backup heater
Rated heat output
(2)
P
sup
kW 1.3 1.3 1.7 2.1 1.4 1.1 1.7 2.0 2.0 2.7
Type of energy used - - Electric
Electricity consumption in modes other than the active mode
Shutdown mode P
OFF
W 8 8 8 8 14 14 14 14 14 14
Thermostat shutdown mode P
TO
W 45 22 72 25 44 32 66 43 88 32
Standby mode P
SB
W 12 12 12 12 17 17 17 17 17 17
Casing resistance mode P
CK
W 0 0 0 0 0 0 0 0 0 0
Other characteristics
Power control
- - Inverter
For air/water heat pumps, rated air ow rate,
outdoors
- m3/h 6200 6900
(1)
The calculation details are available on the package datasheet. The room unit refers to: sensors, thermostats and remote controllers
included, or not included, in the kits.
(2)
For heat pump space heaters and heat pump combination heaters, the rated heat output P
rated
is equal to the rated caloric load P
designh
,
and the rated heat output of the backup heater P
sup
is equal to the caloric output of the extra backup heating (Tj).
(3)
If Cdh is not determined by measurement then the default degradation coecient is Cdh=0.9.