FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE
STATEMENT: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this
equipment.
CE Warning: This is a class A product. In a domestic environment this product
may cause radio interference in which case the user may be required to take
adequate measures.
RoHS
This product is RoHS compliant.
SJ/T 11364-2006
The following contains information that relates to China.
ii
eco PDU PE Series User Manual
User Information
Online Registration
Be sure to register your product at our online support center:
Internationalhttp://eservice.aten.com
Telephone Support
For telephone support, call this number:
International886-2-8692-6959
China86-10-5255-0110
Japan81-3-5615-5811
Korea82-2-467-6789
North America1-888-999-ATEN ext 4988
United Kingdom44-8-4481-58923
User Notice
All information, documentation, and specifications contained in this manual are subject to change
without prior notification by the manufacturer. The manufacturer makes no representations or
warranties, either expressed or implied, with respect to the contents hereof and specifically
disclaims any warranties as to merchantability or fitness for any particular purpose. Any of the
manufacturer's software described in this manual is sold or licensed as is. Should the programs
prove defective following their purchase, the buyer (and not the manufacturer, its distributor, or its
dealer), assumes the entire cost of all necessary servicing, repair and any incidental or
consequential damages resulting from any defect in the software.
The manufacturer of this system is not responsible for any radio and/or TV interference caused by
unauthorized modifications to this device. It is the responsibility of the user to correct such
interference.
The manufacturer is not responsible for any damage incurred in the operation of this system if the
correct operational voltage setting was not selected prior to operation. PLEASE VERIFY THAT
THE VOLTAGE SETTING IS CORRECT BEFORE USE.
iii
eco PDU PE Series User Manual
Set the maximum permissible breaker protection in the building circuitry to the
current rating specified on the rating plate. Observe all national regulations and
safety codes as well as deviations for breakers.
Only connect the PE Device to a grounded power outlet or a grounded system!
Make sure that the total current input of the connected systems does not exceed
the current rating specified on the rating plate of the PE Device.
There is a risk of explosion if the battery is replaced with an incorrect type.
Dispose of used batteries according to the relevant instructions.
PE Device Safety Notice
Consignes de sècuritè relatives à l’unitè PE
Installez sur le circuit du bâtiment des disjoncteurs permettant d’assurer la
protection maximale autorisée, en respectant le courant nominal spécifié sur la
plaque signalétique. Veuillez respecter l’ensemble des réglementations nationales
en vigueur et des codes de sécurité ainsi que les déviations recommandèes pour
les disjoncteurs.
Ne connectez l’unité PE qu’à une prise de courant avec borne de terre ou à un
système mis à la terre!
Assurez-vous que le courant d’entrée total des systèmes connectés ne dépasse pas
le courant nominal spécifié sur la plaque signalétique de l’unité PE.
Il existe un risque d’explosion si la batterie est remplacée par une batterie de type
incorrect. Jetez les batteries usagées en respectant les instructions adequates.
NRGence and the NRGence logo are registered trademarks of ATEN International Co., Ltd. All rights reserved.
All other brand names and trademarks are the registered property of their respective owners.
Package Contents
The eco PDU PE Series package consists of:
1 PE5220s, PE5312sGL, PE5312sGR, or PE5340s Power Distribution Unit
1 Power Cord (PE5220s only)
1 Rack Mount Kit
1 User Instructions*
1CD-ROM
Check to make sure that all of the components are present and in good order.
If anything is missing, or was damaged in shipping, contact your dealer.
Read this manual thoroughly and follow the installation and operation
procedures carefully to prevent any damage to the eco PDU or other devices on
the installation.
* Features may have been added to the eco PDU since this manual was
published. Please visit our website to download the most up-to-date version.
This User Manual is provided to help you get the most from your eco PDU
system. It covers all aspects of installation, configuration and operation. An
overview of the information found in the manual is provided below.
Chapter 1, Introduction, introduces you to the eco PDU system. Its purpose,
features and benefits are presented, and its front and back panel components
are described.
Chapter 2, Hardware Setup, provides step-by-step instructions for setting
up your installation.
Chapter 3, Basic Operation and First Time Setup, explains the
procedures that the Administrator employs to set up the eco PDU network
environment, and change the default username and password.
Chapter 4, Browser Operation, describes how to log in to the eco PDU with
an internet browser, and explains the layout and components of the eco PDU’s
user interface.
An Appendix, provides specifications and other technical information
regarding the eco PDU.
Conventions
This manual uses the following conventions:
MonospacedIndicates text that you should key in.
[ ]Indicates keys you should press. For example, [Enter] means
to press the Enter key. If keys need to be chorded, they
appear together in the same bracket with a plus sign
between them: [Ctrl+Alt].
1.Numbered lists represent procedures with sequential steps.
♦Bullet lists provide information, but do not involve sequential
steps.
→Indicates selecting the option (on a menu or dialog box, for
example), that comes next. For example, Start
means to open the Start menu, and then select Run.
Indicates critical information.
→ Run
ix
eco PDU PE Series User Manual
Product Information
For information about all NRGence™ products and how they can help you
save money in the data center, visit NRGence™ on the Web or contact an
ATEN Authorized Reseller. Visit ATEN on the Web for a list of locations and
telephone numbers
International – http://www.aten.com
North America – http://www.aten-usa.com
x
Chapter 1
Introduction
Overview
As part of its NRGence™ line, ATEN has developed a new generation of green
energy power distribution units (PDUs) to effectively increase the efficiency of
data center power usage. The NRGence™ PE5220s, PE5312sGL,
PE5312sGR, and PE5340s are intelligent PDUs that contain 12/20/40 AC
outlets and are available in IEC or NEMA input configurations. The basic
characteristics of each model are shown in the tables on page 4.
The PE5220s, PE5312sGL, PE5312sGR, and PE5340s provide secure,
centralized, intelligent, power management of data center IT equipment
(servers, storage systems, KVM switches, network devices, serial data devices,
etc.), as well as the ability to monitor the data center's environmental health via
sensors*.
NRGence™ eco PDUs offer remote power control combined with real-time
power measurement - allowing you to control and monitor the power status of
devices attached to the PDUs, either at the PDU device or bank level, from
practically any location via a TCP/IP connection.
The eco PDU also offers comprehensive power analysis reports which can
separate departments and locations, providing precise measurements of
current, voltage, power and watt-hour in a real-time display.
Installation and operation is fast and easy: plugging cables into their
appropriate ports and user-friendly browser-based management is all that is
entailed. Since the eco PDU firmware is upgradeable over the net, you can stay
current with the latest improvements by simply downloading updates from our
website as they become available.
NRGence™ eco PDUs support any 3rd party V1, V2, V3 SNMP Manager
Software and NRGence™ eco Sensors software (eco PDU Manager Software).
eco Sensors provide you with an easy method for managing multiple devices,
offering an intuitive and user-friendly Graphical User Interface that allows you
to configure a PDU device and monitor the power status of the equipment
connected to it.
(Continues on next page.)
1
eco PDU PE Series User Manual
(Continued from previous page.)
With its advanced security features and ease of operation, the PE5220s
PE5312sGL, PE5312sGR, and PE5340s eco PDUs are the most convenient,
most reliable, and most cost effective way to remotely manage power access
for multiple computer installations and allocate power resources in the most
efficient way possible.
Note: 1. Sensors are optional accessories. A sensor-enabled installation is
required to generate more complete energy-efficient data readings
and charts. Higher sensor installation density is helpful to generate
more accurate data. See Optional Accessories, page 8, for further
information.
2. eco PDUs are primarily designed for access via Intranet; extra
network security protection is suggested for Internet access usage.
Supports multiple power control methods – Wake on LAN, System after
AC Back, Kill the Power
Power-on sequencing – users can set the power on sequence and delay
time for each port to allow equipment to be turned on in the proper order
Easy setup and operation via a browser-based user interface
Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari, Opera,
Netscape)
RTC support to keep the timer running during times of no power.
Supports up to 8 user accounts and 1 administrator account; supports 2
concurrent logins
5
eco PDU PE Series User Manual
Management
Power status measurement at the PDU/Bank level
LED indicators for current and IP address at the PDU device and at the
Bank (PE5340s only) level
Real-time aggregate current, voltage, power, and power dissipation
displayed in a browser-based UI for monitoring at the PDU and bank level.
Environment monitoring – supports external temperature / humidity /
differential pressure sensors for rack environment monitoring
Current and voltage threshold setting
Naming support for outlets
User outlet access assignment on an outlet-by-outlet basis.
Event logging and syslog support
Upgradeable firmware
Multilanguage support: English, Traditional Chinese, Simplified Chinese,
Two-level password security
Strong security features include strong password protection and advanced
encryption technologies – 128 bit SSL
Remote authentication support: RADIUS
eco Sensors Energy Management Software*
Automatic discovery of all PE devices within the same intranet
Remote real-time power measurement and monitoring
Real-time environment sensor monitoring
Plotting/monitoring of all PE devices
Exceed threshold alert through SMTP and System log
Power Analysis report
Note: eco Senors is designed to work with NRGence™ PDUs, and is bundled
with all PE series packages.
6
Chapter 1. Introduction
Requirements
Browsers accessing the eco PDU unit must support SSL 128 bit
encryption.
For cold booting of attached computers, the computer's BIOS must
support Wake on LAN or System after AC Back.
For Safe Shutdown:
The computer must be running Windows (Windows 2000 or higher) or
Linux.
The Safe Shutdown program (available by download from our website
or on the software CD included), must be installed and running on the
computer.
7
eco PDU PE Series User Manual
Optional Accessories
Sensors
Sensors are optional accessories. You can use the eco PDU unit without
sensors. However, if you want to have complete energy management of an
instrumented data center with the use of the eco PDU, you would need to use
eco Sensors software and install 4 sensors for each of the racks to generate a
complete energy-efficient data reading and chart. Higher sensor installation
density is helpful to generate more accurate data. 16/20/24-port models have 2
sensor ports. In this case, Sensor 1 needs to be installed at the intake of the rack
and sensor 2 needs to be placed at the exhaust of IT equipment of the rack. A
sensor-enabled installation is required to generate a more complete energyefficient data reading and chart. Higher sensor installation density is helpful to
generate more accurate data. Available sensors are show in the table, below:
SensorPart Number
Temperature EA1140
Temperature / HumidityEA1240
Differential Pressure / TemperatureEA1340
Sensor Management
Sensors can be managed via the eco PDU’s built-in graphical user interface
(GUI) or with the NRGence™ eco Sensors software that can be downloaded
from the ATEN website. The download link can be found on the software CD
provided with the eco PDU package.
Cable Holders
Cable holders are optional accessories. For added safety, use ATEN Lok-UPlug cable holders to secure the cables from your attached devices in place on
the eco PDU unit. Use only the ATEN Lok-U-Plug cable holders that have
been specifically designed to work with the eco PDU. Using any other kind of
cable securing device could be highly dangerous.
Part NumberDescription
2X-EA07Lok-U-Plug Cable Holder (10 pcs)
2X-EA08Lok-U-Plug Installation Tool (4 pcs)
8
Chapter 1. Introduction
Components
PE5220sB-AX-J / PE5220sB / PE5220sG Front View
1
2
3
5
6
4
9
eco PDU PE Series User Manual
No.ItemDescription
1Power InletThe power cord that connects the unit to an AC
2Circuit Breaker
Pushbutton
3Sensor PortsExternal sensors plug into these two RJ-11 ports.
4LAN Port and LEDsThe cable that connects the eco PDU to the LAN
5Readout Section, LEDs
and Reset Switch
6Power Outlets20 x IEC 60320 C13
power source plugs into this NEMA L6-20R socket
(PE5220sB-AX-J); NEMA 6-20R socket
(PE5220sB); or IEC 60320 C19 socket
(PE5220sG).
As a safety measure, if there is an over-current
situation regarding the device’s power, the circuit
breakers will trip. Press the button to recover
normal operation.
plugs in here. The Link and LAN LEDs are built
into the LAN port:
Link: Lights GREEN to indicate that a connection
via the eco PDU's RJ-45 Ethernet port has been
established. Flashes to indicate data is being
transmitted.
LAN: Lights ORANGE to indicate 10 Mbps data
transmission speed. The LED lights GREEN to
indicate 100 Mbps data transmission speed.
Details of this section are provided on page 19.
Note: Holes for ATEN Lok-U-Plug cable holders are located around the
outlets. See Securing the Cables, page 25, for further information.
10
Chapter 1. Introduction
1
3
4
5
6
2
PE5220sA-AX-J / PE5220sA Front View
11
eco PDU PE Series User Manual
No.ItemDescription
1Power InletThe power cord that connects the unit to an AC
2Circuit Breaker
Pushbutton
3Sensor PortsExternal sensors plug into these two RJ-11 ports.
4LAN Port and LEDsThe cable that connects the eco PDU to the LAN
5Readout Section, LEDs
and Reset Switch
6Power Outlets20 x NEMA 5-15R
power source plugs into this NEMA L5-20R socket
(PE5220sA-AX-J); NEMA 5-20R socket
(PE5220sA).
As a safety measure, if there is an over-current
situation regarding the device’s power, the circuit
breakers will trip. Press the button to recover
normal operation.
plugs in here. The Link and LAN LEDs are built
into the LAN port:
Link: Lights GREEN to indicate that a connection
via the eco PDU's RJ-45 Ethernet port has been
established. Flashes to indicate data is being
transmitted.
LAN: Lights ORANGE to indicate 10 Mbps data
transmission speed. The LED lights GREEN to
indicate 100 Mbps data transmission speed.
Details of this section are provided on page 19.
Note: Holes for ATEN Lok-U-Plug cable holders are located around the
outlets. See Securing the Cables, page 25, for further information.
12
Chapter 1. Introduction
1
2
3
4
3
5
6
PE5312sGL Front View
13
eco PDU PE Series User Manual
No.ItemDescription
1Power ConnectionThe power cord that connects the unit to an AC
2Circuit Breakers As a safety measure, if there is an overcurrent
3Power Outlets*Bank1 : Outlet 1–6; 6 x UK BS1363 (90 Degree)
4Sensor PortsExternal sensors plug into these two RJ-11 ports.
5LAN Port and LEDsThe cable that connects the eco PDU to the LAN
6Readout Section, LEDs
and Reset Switch
power source plugs into an IEC 60309 32A power
supply.
situation regarding the device’s power, the circuit
breakers will trip.
Bank2 : Outlet 7–12; 6 x UK BS1363 (90 Degree)
plugs in here. The Link and LAN LEDs are built
into the LAN port:
Link: Lights GREEN to indicate that a connection
via the eco PDU's RJ-45 Ethernet port has been
established. Flashes to indicate data is being
transmitted.
LAN: Lights ORANGE to indicate 10 Mbps data
transmission speed. The LED lights GREEN to
indicate 100 Mbps data transmission speed.
Details of this section are provided on page 20.
Note: Holes for ATEN Lok-U-Plug cable holders are located around the
outlets. See Securing the Cables, page 25, for further information.
14
Chapter 1. Introduction
1
2
3
4
3
5
6
PE5312sGR Front View
15
eco PDU PE Series User Manual
No.ItemDescription
1Power ConnectionThe power cord that connects the unit to an AC
2Circuit Breakers As a safety measure, if there is an overcurrent
3Power Outlets*Bank1 : Outlet 1–6; 6 x UK BS1363 (270 Degree)
4Sensor PortsExternal sensors plug into these two RJ-11 ports.
5LAN Port and LEDsThe cable that connects the eco PDU to the LAN
6Readout Section, LEDs
and Reset Switch
power source plugs into an IEC 60309 32A power
supply.
situation regarding the device’s power, the circuit
breakers will trip.
Bank2 : Outlet 7–12; 6 x UK BS1363 (270 Degree)
plugs in here. The Link and LAN LEDs are built
into the LAN port:
Link: Lights GREEN to indicate that a connection
via the eco PDU's RJ-45 Ethernet port has been
established. Flashes to indicate data is being
transmitted.
LAN: Lights ORANGE to indicate 10 Mbps data
transmission speed. The LED lights GREEN to
indicate 100 Mbps data transmission speed.
Details of this section are provided on page 20.
Note: Holes for ATEN Lok-U-Plug cable holders are located around the
outlets. See Securing the Cables, page 25, for further information.
16
Chapter 1. Introduction
1
2
3
4
3
5
6
PE5340s Front View
17
Loading...