Atek INC 210 User Manual

1
Signal
M12 Socket
V+ (12..24VDC)
Pin 1
Red
Output 1 (0.1-10VDC / 4-20mA) (X axis)
Pin 2
Yellow
GND (0V)
Pin 3
Black
Output 2 (0.1-10VDC / 4-20mA) (Y axis)
Pin 4
Green
Reset
Pin 5
Pink
The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams,
There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless
Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and
Not to damage the sensor, supply directions and voltage must be paid attention. Don’t energize before all connections
Transport and storage should be at their original packaging and an ambient temperature of -30°C / +70°C in such a way that
Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a
INC 210 (Analog Output)
ANGLE SENSOR USER MANUAL
WARNINGS
ELECTRICAL CONNECTION
DETERMINING THE 0° POINT OF SENSOR
Thus, the sensor
recognizes that the position is 0 °. If the same operation is repeated a second time, the sensor is reset to the factory
During the operations, the sensor position should be kept constant for approximately 4 seconds.
M12 - 5 PIN MALE
* Output 2 is only used on two-axis models. On single-axis models, Pin 4 (green
GENERAL INFORMATIONS
INC 210 series angle sensors are the sensors that show the angle of rotation of objects standing perpendicular to the earth. Angle measurement information between 0°-360°
20mA current output option, can take measure ment with ±0.1° accuracy. Thanks to its
environments with their high IP protection classes. Optionally, sensors with redundant output can be produced.
M12 - 5 PIN
FEMALE SOCKET
can be taken from these sensors. These sensors with 0.1-10VDC voltage output or 4-
compensated axis sensitivity, the effect of the axes on each other is minimized.
These sensors, especially used in machine and crane industries, can operate in outdoor
installation information, etc. in this manual.
Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
it needs.
capacitive noisy supplies.
completed.
they will not be exposed to dust, humudity, impact, vibration, falling or water.
damp cloth.
The product may be damaged and may become unusable if used outside of the specifications in the user manual.
SOCKET
cable) is empty. * On single output models, 1 pcs M12 5 pin male socket is used as standard. * Redundant models have two outputs. 1 pcs M12 5 pin male ve 1 pcs M12 5 pin female socket is used as standard. * Different socket models can be requested optionally.
Pin 5 (pink cable) and pin 3 (black cable) are short-circuited for about 2 seconds and then disconnected.
settings.
KK-INC.006 18.01.19 Rev No:1
2
The product must be fixed to the area to be taken inclination
Warning: All welding work in the relevant area must be completed before the product is installed. Otherwise, the device may be damaged during the welding process, and in this case, it will be out of warranty.
0-360⁰
DIMENSIONS (in mm)
MEASUREMENT AXIS AND OUTPUT DIAGRAM
MECHANICAL MOUNTING
Analog Signal Output
measurement with 3 pcs M6 bolts and nuts.
KK-INC.006 18.01.19 Rev No:1
3
Supply Voltage
4-20 mA : 12 24 VDC
0-10 VDC: 15 … 24 VDC
Protection Class
IP67
*Measurement
Range
0 360
Operating Temperature
- 30°C … +70°C
Relative Humudity
%10 %90
*Output Signals
Analog 4-20 mA or 0.1-10 VDC Optional Redundant Output
Weight
~250 gr
Resolution
12 bit
Body Material
Aluminium
Accuracy
±0,1⁰
*Electrical Connection
M12 5 pin (male) socket or cable output
Note: The specifications specified by (*) vary depending on the model selected. The detailed code table for product selection is shown on page 4.
Product
Description
INC 210
Angle Sensor
User Manual
1 pcs.
TECHNICAL SPECIFICATIONS
PRODUCT CODE TABLE
BOX CONTENTS
Supply Voltage
(1)
Sensor Type
Model
Number of axes
Output Signals
A: 4-20 mA
Electrical Connection
(3)
Measurement Range
(2)
180: 0-180°
Output Signal Direction
CCW: Counter-Clockwise
Output Type
(1) The supply voltage is 12…24VDC for 4-20 mA output models, and 15…24VDC for 0-10 VDC output models. (2) Optionally, different measurement values between 0-360° can be requested. You should specify your non-standard measurement
(3) The product can be requested with cable or socket.
INC 210 series, angle, single axis, 0-360° measurement, 12-24VDC supply, current output, clockwise, 1 pcs M12 5 pin female soket,
INC 210 series, angle, single axis, 0-180° measurement, 15-24VDC m, volt output, counter-clockwise, 1 pcs M12 5 pin female + 1 pcs
INC 210
01: Single axis
PP: 12…24VDC /
15…24VDC
CW: Clockwise
No code : Single Output Dual : Redundant
output
INC 210 X
XX
XX XX XXX
XX XX XX
A : Angle
360: 0-360°
V: 0-10 VDC
3M : 3m cable
5M : 5m cable
10M : 10m cable S13F : M12 5 pin female socket S13M : M12 5 pin male socket S13FM: M12 5 pin female + M12 5 pin
male socket (redundant models)
value at the order stage.
As standard; For single output models, 1 pcs M12 5 pin male socket (S13M) is used. For redundant models, 1 pcs M12 5 pin female + 1 pcs M12 5 pin male socket (S13FM) is used. However, different socket combinations may be requested as in the examples below.
Please contact us for any other socket model other than M12.
Sample Code 1: INC210-A-01-360-PP-A-CW-S13F
single output
Sample Code 2: INC210-A-01-180-PP-V-CCW-S13FM-DUAL
M12 5 pin male socket, redundant output
KK-INC.006 18.01.19 Rev No:1
4
Manufacturer Firm’s Title, Address Details
Disposal of Packagings: Packaging materials consist of recyclable materials. For providing
recycling, please dispose waste packagings to collecting points of authorized recycling facilities. Disposal of E-Waste: This device is in conformity with WEEE Directive and consists of recyclable materials. This product should not be disposed with general waste for preventing negative
effects on enviroment and human health. This product should be disposed to collecting points
of authorized recycling facilities. Further information can be reached from authorized unit.
Address: Tuzla KOSB Organize Sanayi Bolgesi Melek Aras Bulvari, No:67 34956 Tuzla-Istanbul / TURKEY
Address: Tuzla KOSB Organize Sanayi Bolgesi Melek Aras Bulvari, No:67 34956 Tuzla-Istanbul / TURKEY
Manufacturer Firm: ATEK SENSÖR SANAYİ VE TİCARET A.Ş.
TEL: +90 0216 399 44 04 FAX: +90 0216 399 44 02
Web: www.ateksensor.com E-mail: info@ateksensor.com
Authorized Service’s Title, Address Details
Authorized Service: ATEK SENSÖR SANAYİ VE TİCARET A.Ş.
TEL: +90 0216 399 44 04 FAX: +90 0216 399 44 02
E-mail: info@ateksensor.com
KK-INC.006 18.01.19 Rev No:1
DISTRIBUTOR / DISTRIBUIDOR
Atek Sensor Technology A.S.
Tuzla Kimya Sanayicileri Org. San. Bolg. Melek Aras Bulvari, No:67 34956 Tuzla-Istanbul / TURKEY
Brazil and South America / Brasil e América do Sul
Metrolog Controles de Medição
Address / Endereço:
Rua Sete de Setembro, 2656 13560-181 - São Carlos - SP Brazil / Brasil
Phone / Telefone:
+55 (16) 3371-0112 +55 (16) 3372-7800
Internet:
www.metrolog.net metrolog@metrolog.net
Tel: +90 216 399 44 04 Fax: +90 216 399 44 02
www.ateksensor.com
info@ateksensor.com
Loading...