TDR900
CIRCUIT BREAKER TEST SYSTEM
Performs timing functions for up to 4 breaks per phase
with motion measurements for any circuit breaker.
The TDR900 is a state-of-the-art Circuit Breaker Test System engineered to test all types of
circuit breakers. The TDR900 provides efficient and accurate performance measurements
for circuit breakers. It allows simple to complex testing of circuit breakers using a single,
rugged, field-portable instrument.
TDR900 Benefits:
• Rugged and Reliable - the TDR900 is a single box solution, providing the accuracy
of a laboratory instrument with durability for eld use.
• Complete Test Reports - provided in MS Excel™ format.
• User-friendly PC interface - the new T-Doble Software with its intuitive control panel
provides quick, efcient and simple testing of circuit breakers.
• High Accuracy Motion Recording - a patented digital rotary and linear transducer provide early diagnosis of mechanical problems.
• Detects main contact and resistor switch timing errors.
• Other analog transducers supported.
• Immune to Interference - accuracy of test results is unaffected by the severe conditions of electrostatic and electromagnetic interference, normally present in harsh
substation environments.
• Controlled by user supplied PC.
T-Doble Software (included
with the TDR900) allows simple
congurable display of results
and user congurable reports
TDR900 Features:
TDR900 controls circuit breaker trip and
close commands, allowing the user to
perform the following operations:
• Trip (O)
• Close (C)
• Reclose (O-0.3s-C)
• Tripfree (CO)
• O-CO
• O-0.3s-CO
• First Trip (O)
• Slow Close (C)
• Self Diagnostics
The TDR900 comes with New T-Doble
Software for improved data management
capability.
• Intuitive and clear: easy-to-use test
plans and test results
• Data can be plotted, overlaid, analyzed,
and printed
• Will import all TR3100 and TDR9000
test result data and test plans
TDR900 Accessories:
• Doble Current Probes (20 A / 200 A ranges)
• Optional 90 ft / 27 m Test Cable
(Specify O.C.B. or E.H.V. and quantity)
• Safety Cable 25 ft
• Safety Flag Plug
• Printer Model P1 External USB Thermal Printer
• Mechanical Adapter Clamp Set
(Kit includes three (3) C-Clamps and six (6) Vise-Grip C-Clamps)
• Additional T-Doble Software
TDR900 Technical Specifications:
Main Contact and Resistor Switch Timing
Number of Phases: 3
Breaks Per Phase: 4
OCB Conguration: 3 Contacts
EHV Conguration: [3, 6, 9, 12] Contacts
Resolution: 100 ms
Resistor Detection Range: 10 W to 10 kW
Voltage Isolation to Chassis: 1.0 kV
Trip/Close Initiation Control
Maximum Input Current: ± 25 A
Maximum Input Voltage: ± 300 V
Voltage Isolation to Chassis: 1.0 kV
Motion Channels
Number of Channels: 3
Connector: 15-pin “D”
Voltage Isolation to Chassis: 1.0 kV
Analog Measurement Channels (3A)
Number of Channels: 3
Maximum Input Voltage: ± 300 V
Input Impedance: 1 MW
Resolution: 12 Bit
Ranges: ± 300 V, ± 10 V, ± 2 V, ± 0.2 V
Voltage Isolation to Chassis: 1.0 kV
Auxiliary Contact Channels (3X)
Number of Channels: 3
Maximum Input Voltage: ± 300 V
Open Circuit Voltage: 29 V ± 10%
Close Circuit Current: 28 mA ± 10%
Voltage Isolation to Chassis: 1.0 kV
Digital Linear/Rotary Motion Transducer
Linear Rotary
Range: 0.0 to 40.0” 0.0 to 2880.0°
0.0 to 1000.0 mm
Accuracy: +/-0.1% of the value +/- 0.1% of the value
Measurement
Resolution: 0.00125” 0.09°
Velocity: 50 ft/s 120 rev/s max
Acceleration: 1200 g for 50 ms max 30x106°/s2 max
General
Recordings: 25 seconds (all channels at max resolution)
Communication: USB or Ethernet
Safety: Safety Ground
+/- 0.1” max error +/- 0.1° max error
0.03 mm
15 m/s
Up to 30 min (reduced resolution)
Safety Switch (local and remote)
Audible Indication (test in progress)
Physical Specifications:
Doble Engineering Company
85 Walnut Street
Watertown, MA 02472 USA
tel +1 617 926 4900
fax +1 617 926 0528
TOGETHER WE POWER THE WORLD
Dimensions: 24.0 X 15.5 X 8.5 in
60.9 X 39.4 X 21.6 cm
Weight: 22 lbs / 10 kg
Power Supply: 100 – 240 V, 50/60 Hz
Temperature: 0° to 50° C operating,
-25° to + 70° C storage
Humidity: Up to 95% relative humidity non-condensing