Atec TCP0150 User Manual

AC/DC Current Probe
TCP0150 Datasheet
Provides Au tomatic Units Scaling and Readout on the Oscilloscope's Display
Remote GPIB/USB Probe Control through the Oscilloscope
Split-core Probe Head Construction Allows Easy Connection to Conductors
TCP0150
Features & Benets
o-Use and Accurate AC/DC Current Measurement s
Easy-t
Connects Directly to Oscilloscopes with the TekVPI™ Probe Interface
DC to 20
150 A
500 A P
High Accuracy with Typically Less T han 1% DC Gain Error
Accur
Low Noise and DC Drift
Maximum Current Capability
RMS
eak Pulse Current Capability
ately Measures Current levels as Low as 5 mA
Easy to Dega
Setup Controls and Probe Status and Diagnostic Indicators are Provided on Both the Probe Hardware a nd through an Easy-to-Access Scope UI Display Menu
uss and Autozero
Applications
Power Supplies
Semiconductor Devices
Power Inv
Electronic Ballasts
Industrial/Consumer Electronics
Motor Drives
Transportation Systems
TCP0150 is a high pe rformance and easy-to-use 150 A AC/DC current probe designed for use and direct con nection to the TekVPI™ probe interface. This AC/DC current measuremen t probe provides 20 MHz of frequency bandwidth with selectable range control for 25 A and 150 A measure and accuracy to current levels as low as 5 mA per division – important for achieving broad dynamic current range of high-level and low-level measurement signals.
erters/Converters
ment ranges. It also provides low-current mea surement capability
Datasheet
Characteristics
Warranted
Characteristic
Bandwidth
Rise Time 17.5 ns Max RMS Current Max Peak Pulse Current Minimum Sensitivity 5 mA (on oscilloscope’s 1 mV/div setting)
Current Ranges Max Bare-wire Voltage
Typical
Characteristic
DC Accuracy ±1% Typical
Max Amp-second Product
25 A Range 3,000 Aµs 150 A Range 15,000 Aµs
Insertion Impedance
Signal Delay Displayed RMS Noise 500 μA
Description
DC to 20 MHz (-3 dB). Derate with Frequency. See Figure 1. (Calculated from Rise Time BW = .35/Rise Time)
150 A 500 A
AC Coupling (on oscilloscopes th at support AC/DC coupling)
25 A and 150 A
CAT I and II
600 V
RMS
300 V
CAT III
RMS
Description
3% Warranted
0.03 at 1 MHz
0.075 at 5 MHz .125 at 10 MHz .3 at 20 MHz 21 n s
(probe only)
RMS
Environmental
Characteristic
Description
Temperature
Operating 0 ºC to +50 ºC Nonoperating
-40ºCto+75ºC
Humidity
Operating 5% to 95% RH (Relative Humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +50 ºC, noncondensing
Nonoperating
5% to 95% RH (Relative Humidity) at up to +30 ºC 5% to 85% RH above 30 ºC up to +75 ºC, noncondensing
Altitude
Operating Up to 2,000 meters (6,560 feet) Nonoperating
Up to 12,000 meters (40,000 feet)
Physical Characteristics
Dimension Meters Inches
Cable Length
2 meters 79 in.
Probe head size
Length 26.8 cm 10.55 in. Width 4.1 cm 1.6 in. Height 15.6 cm 6.13 in.
Max Conductor Diameter
Weight kg lb.
Shipping Power Requirements
21mmx25mm 0.83in. x1.0in.
.7865 1.734
TCP0150 is powered directly by oscilloscopes
with the TekVPI interface
Recommended Oscilloscopes
Oscilloscopes with the TekVPI probe interface. Note: For best probe support, download and install the latest version of the
oscilloscope software from www.tektronix.com
2 www.tektronix.com
Loading...
+ 2 hidden pages