Atec S331E, S332E, S361E, S362E User Manual

Manufacturers > Anritsu Categories > Wireless, Antenna, Base Station Test > Cable & Antenna Analyzers, Site Masters, Sweepers
Anritsu S332E Site Master Product Page
Technical Data Sheet
Anritsu S331E Site Master Product Page Anritsu S362E Site Master Product Page
Site Master
How-To Video:
Compact Handheld Cable & Antenna Analyzer with Spectrum Analyzer
S331E S332E S361E S362E
2 MHz to 4 GHz 2 MHz to 4 GHz 2 MHz to 6 GHz 2 MHz to 6 GHz Cable & Antenna Analyzer
100 kHz to 4 GHz 100 kHz to 6 GHz Spectrum Analyzer
Introduction
Anritsu introduces its eighth generation compact handheld Cable and Antenna Analyzers with Spectrum Analyzers for installation and maintenance of wireless networks. They feature the highest performance and the most capabilities ever offered by Anritsu in a compact handheld tester since introducing its first line sweeper in 1995.
Cable and Antenna Analyzer Highlights
Measurements: RL, VSWR, Cable Loss, DTF, Phase 2-port Transmission Measurement: High/Low Power Sweep Speed: 1 msec/data point, typical Display: Single or Dual Measurement Touchscreen Calibration: OSL, InstaCal Bias Tee: 32 V internal
, and FlexCal
Spectrum and Interference Analyzer Highlights
Measurements: Occupied Bandwidth, Channel Power, ACPR, C/I Interference Analyzer: Spectrogram, Signal Strength, RSSI, Signal ID,•
Interference Mapping Dynamic Range: > 95 dB in 10 Hz RBW DANL: -152 dBm in 10 Hz RBW Phase Noise: -100 dBc/Hz max @ 10 kHz offset at 1 GHz Frequency Accuracy: < ± 50 ppb with GPS On
Capabilities and Functional Highlights
4 hour battery operation time• Store 2000 Traces internally• Touchscreen keyboard• Quick Name Matrix• PIM Analyzer• AM / FM / PM Analyzer• High Accuracy Power Meter•
4, 6, 8, 18, 26 GHz USB Sensors• On-Screen Interference Mapping• On-Screen Coverage Mapping• GPS tagging of saved traces• USB & Optional Ethernet•
(Option 0411) for data transfer and instrument control
Increase throughput by• automating repetitive or operator intensive tasks via Ethernet or USB. Remote programming provided via Ethernet (Option
0411) < 5 minute warm-up time•
E-Learning Training• Certified Line Sweep Training• Line Sweep Tools
Site Master™ S331E Cable & Antenna Analyzer featuring 8.4” Daylight Viewable Touchscreen
Compact Size: 273 mm x 199 mm x 91 mm (10.7 in x 7.8 in x 3.6 in), Lightweight: 2.71 kg (6.0 lbs)
Site Master™ S331E, S332E, S361E, S362E Specifications
Cable and Antenna Analyzer
Measurements
Measurements VSWR
Return Loss Cable Loss
Distance-to-Fault (DTF) Return Loss Distance-to-Fault (DTF) VSWR
1-Port Phase Smith Chart
Setup Parameters
Measurement Display Single/Dual Measurement Display with independent markers
Frequency Start/Stop, Signal Standard, Start Cal
DTF Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing
Windowing Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude Top, Bottom, Auto Scale, Full Scale
Sweep Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Aver a ging/Smoothing,
Data Points 137, 275, 551, 1102, 2204
Markers Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Marker Table
Traces Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay
Limit Line On/Off, Single Limit, Multi-segment (41), Limit Alarm, Clear
Calibration Start Cal, Cal Type (Standard/FlexCal™)
Save/Recall Setups, Measurements (.vna, .dat), Screen Shots Jpeg (save only)
Application Options Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Frequency
Frequency Range 2 MHz to 4 GHz (S331E, S332E), 2 MHz to 6 GHz (S361E, S362E)
Frequency Accuracy ≤ ± 2.5 ppm @ 25 °C
Frequency Resolution 1 kHz, (RF immunity low)
Output Power
High 0 dBm, typical
Low –30 dBm, typical
Interference Immunity
On-Channel +17 dBm @ > 1.0 MHz from carrier frequency
On-Frequency 0 dBm within ± 10 kHz of the carrier frequency
Measurement Speed
Return Loss ≤ 1.00 msec/data point, RF immunity low, typical
Distance-to-Fault ≤ 1.25 msec/data point, RF immunity low, typical
Return Loss
Measurement Range 0 to 60 dB
Resolution 0.01 dB
VSWR
Measurement Range 1 to 65
Resolution 0.01
Cable Loss
Measurement Range 0 to 30 dB
Resolution 0.01 dB
Distance-to-Fault
Vertical Range Return Loss 0 to 60 dB
Vertical Range VSWR 1 to 65
Fault Resolution (meters) (1.5 x 10
Horizontal Range (meters) 0 to (Data Points-1) x Fault Resolution, to a maximum of 1500 meters (4921 ft)
1-Port Phase
Measurement Range –180° to +180°
Resolution 0.01°
Smith Chart
Resolution 0.01
Output Power (High/Low)
100 kHz, (RF immunity high)
8
x vp)/∆F (vp = velocity propagation constant, ∆F is F2-F1 in Hz)
Page 2 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Cable and Antenna Analyzer (continued)
Measurement Accuracy
Corrected Directivity > 42 dB, OSL Calibration
Measurement Uncertainty
Optical Distance-to-Fault Module (P/N ODTF-1)
Wavelength 1550 nm, typical
Event Resolution 10.2 cm (0.335 ft) maximum, or 150 / (n*ΔF), ΔF in MHz, n is IOR
Horizontal Range 1020 meter (3345 ft) maximum, or (#dp-1) *Event Resolution
Optical Dynamic Range 30 dB
Optical Output Power 3 dBm, typical
RF Connector N(m)
Optical Connector FC/APC
> 38 dB, InstaCal™ Calibration
Fiber Type Single Mode Fiber
Datasheet 11410-00478 (for complete specications)
PIM Analyzer (Option 0419) (Requires PIM Master™)
2-Port Transmission Measurement (Option 0021)
Frequency
Frequency Range 2 MHz to 4 GHz (S331E, S332E), 2 MHz to 6 GHz (S361E, S362E)
Frequency Resolution 10 Hz
Output Power
Dynamic Range
Application Options Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Bias-Tee (Option 0010)
Current (Low/High) 250 mA/450 mA, 1 A surge for 100 ms
See Product Brochure 11410-00546
High 0 dBm, typical
Low –30 dBm, typical
2 MHz to 4 GHz 80 dB 4 GHz to 6 GHz 70 dB
Setup On/Off, Voltage, Current (Low/High)
Voltage Range +12 V to +32 V
Resolution 0.1 V
Page 3 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Spectrum Analyzer (S332E, S362E)
Measurements
Smart Measurements Field Strength (uses antenna calibration tables to measure dBm/m
Occupied Bandwidth (measures 99% to 1% power channel of a signal)
Channel Power (measures the total power in a specied bandwidth)
ACPR (adjacent channel power ratio) AM/FM/SSB Demodulation (wide/narrow FM, USB and LSB), (audio out only) C/I (carrier-to-interference ratio) Emission Mask Coverage Mapping (requires Option 0431)
Setup Parameters
Frequency Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Channel Increment
Amplitude Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
Bandwidth RBW, Auto RBW, VBW, Auto VBW, RBW/VBW, Span/RBW
File Save, Recall, Delete, Directory Management
Save/Recall Setups, Measurements, Limit Lines, Screen Shots Jpeg (save only), Save-on-Event
Save-on-Event Crossing Limit Line, Sweep Complete, Save-then-Stop, Clear All
Delete Selected File, All Measurements, All Mode Files, All Content
Directory Management Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy, Format USB
Application Options Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Sweep Functions
Sweep Single/Continuous, Sweep Mode (Fast, Performance, No FFT), Reset, Detection,
Minimum Sweep Time, Trigger Type, Gated Sweep (see Option 0090)
Detection Peak, RMS, Negative, Sample, Quasi-peak
Triggers Free Run, External, Video, Change Position, Manual
Trace Functions
Traces Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations Trace A Operations Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace) Trace B Operations Trace C Operations
Marker Functions
Markers Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers,
Marker Types Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker
Marker Auto-Position Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel,
Marker Table 1-6 markers frequency and amplitude plus delta markers frequency amplitude and offset
Limit Line Functions
Limit Lines Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit
Limit Line Edit Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right
Limit Line Move To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1
Limit Line Envelope Create Envelope, Update Amplitude, Points (41 max), Offset, Shape Square/Slope
Limit Line Advanced Type (Absolute/Relative), Mirror, Save/Recall
Frequency
Frequency Range 100 kHz to 4 GHz (S332E), 100 kHz to 6 GHz (S362E) (usable to 0 Hz)
Tuning Resolution 1 Hz
Frequency Reference Aging: ± 1.0 ppm/year
Frequency Span 10 Hz to 4 GHz including zero span (S332E), 10 Hz to 6 GHz including zero span (S362E)
Sweep Time Minimum 100 ms, 10 µs to 600 seconds in zero span
Sweep Time Accuracy ± 2% in zero span
Bandwidth
Resolution Bandwidth (RBW) 10 Hz to 3 MHz in 1–3 sequence ± 10% (1 MHz max in zero-span) (–3 dB bandwidth)
Video Bandwidth (VBW) 1 Hz to 3 MHz in 1–3 sequence (–3 dB bandwidth) (auto or manually selectable) RBW with Quasi-Peak Detection 200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth) VBW with Quasi-Peak Detection Auto VBW is On, RBW/VBW = 1
A B, B  C, Max Hold, Min Hold A C, B  C, Max Hold, Min Hold, A - B C, B - A  C, Relative Reference (dB), Scale
Marker Table (On/Off), All Markers Off
Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level
Accuracy: ± 1.5 ppm (25 °C ± 25 °C) + aging, < ± 50 ppb with GPS On
2
or dBmV/m)
Page 4 of 16
Site Master™ S331E, S332E, S361E, S362E Specifications
Spectrum Analyzer (S332E, S362E) (continued)
Spectral Purity
SSB Phase Noise @ 1 GHz –100 dBc/Hz, –110 dBc/Hz typical @ 10 kHz offset
–105 dBc/Hz, –112 dBc/Hz typical @ 100 kHz offset –115 dBc/Hz, –121 dBc/Hz typical @ 1 MHz offset
Amplitude Ranges
Dynamic Range > 95 dB (2.4 GHz), 2/3 (TOI-DANL) in 10 Hz RBW
Measurement Range DANL to +26 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference Level Range –120 dBm to +30 dBm
Attenuator Range 0 to 55 dB, 5.0 dB steps
Maximum Continuous Input +35 dBm
Amplitude Units Log Scale Modes: dBm, dBV, dBmv, dBμV
Linear Scale Modes: nV, μV, mV, V, kV, nW, μW, mW, W, kW
Amplitude Accuracy
100 kHz to 4.0 GHz ± 1.25 dB, ± 0.5 dB typical > 4.0 GHz to 6 GHz ± 1.50 dB, ± 0.5 dB typical
Displayed Average Noise Level (DANL)
Preamp Off
(Reference level -20 dBm)
(RBW Normalized to 1 Hz, 0 dB attenuation) Maximum Typical Maximum Typical
10 MHz to 2.4 GHz –141 dBm –146 dBm –157 dBm –162 dBm
> 2.4 GHz to 4 GHz –137 dBm –141 dBm –154 dBm –159 dBm
>4 GHz to 5 GHz –134 dBm –138 dBm –150 dBm –155 dBm
> 5 GHz to 6 GHz –126 dBm –131 dBm –143 dBm –150 dBm
(RBW = 10 Hz, 0 dB attenuation)
10 MHz to 2.4 GHz –131 dBm –136 dBm –147 dBm –152 dBm
> 2.4 GHz to 4 GHz –127 dBm –131 dBm –144 dBm –149 dBm
> 4 GHz to 5 GHz –124 dBm –128 dBm –140 dBm –145 dBm > 5 GHz to 6 GHz –116 dBm –121 dBm –133 dBm –140 dBm
Spurs
Residual Spurious < –90 dBm (RF input terminated, 0 dB input attenuation, > 10 MHz)
Input-Related Spurious < –75 dBc (0 dB attenuation, –30 dBm input, span < 1.7 GHz, carrier offset > 4.5 MHz)
Exceptions, typical < 70 dBc @ < 2.5 GHz, with 2072.5 MHz Input
< –68 dBc @ F1-280 MHz with F1 Input < –70 dBc @ F1 + 190.5 MHz with F1 Input < –52 dBc @ 7349 - 2F2 MHz, with F2 Input, where F2 < 2424.5 MHz < –55 dBc @ 190.5 ± F1/2 MHz, F1 < 1 GHz
Third-Order Intercept (TOI)
Preamp Off (–20 dBm tones 100 kHz apart, 10 dB attenuation)
800 MHz +16 dBm
2400 MHz +20 dBm
200-2200 MHz +25 dBm, typical
> 2.2 GHz to 5.0 GHz +28 dBm, typical > 5.0 GHz to 6.0 GHz +33 dBm, typical
Second Harmonic Distortion
Preamp Off, 0 dB input attenuation, –30 dBm input
50 MHz –56 dBc
> 50 MHz to 200 MHz –60 dBc, typical
> 200 MHz to 3000 MHz –70 dBc, typical
VSWR
2:1, typical
Preamp On
(Reference level -50 dBm)
Page 5 of 16