Atec P7380A User Manual

Z-Active™ Differential Probe Family
P7313 • P7380A • P7360A • P7340A Data Sheet
Features & Benets
Signal Fidelity
>12.5 GHz Bandwidth (P7313, Typical) >8.0 GHz Bandwidth (P7 380A, Typical) >6.0 GHz Bandwidth (P7 360A, Typical) >4.0 GHz Ban
1.25 V 4V 2V 5V
Low Probe Loading
DC Input Resistance
AC Loading
Versatility
Make Differential or Single-ended (Ground-referenced) Measurements* Solder-down Capability Handheld Probing with Variable Spacing and Compliance Fixtured
Interchangeable Tip-Clip™ Assemblies
Connect to a Variety of Devices Economical
TekConnect®Interface
at 5x Attenuation (P7313)
p-p
at 25x Attenuation (P7313)
p-p
at 5x A
p-p
at 25x Attenuation (P7380A, P7360A, P7340A)
p-p
100 kDiff 50 kSingle Ended
Z
>200 out to 10 GHz (P7313)
min
Z
>290 , 4 GHz to 8 GHz (P7380A, P7360A, P7340A)
min
Probing
dwidth (P7 340A, Typical)
ttenuation (P73 80A, P7360A, P7340A)
erential
1
Applications
Examples Include, but are not Limited To:
PCI-Express I and II, Serial ATA II, USB 2.0, DDRII, DDRIII, Fireware 1394b, Rambus, XAUI
*1For details, please see application note 60W-18344-0, “Making Single-ended Measurements with
Differential Probes.”
Data Sheet
Z-Active™ Probing Architecture Leads the Way for High-speed Probing Applications
Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal delity. Tektronix a ctive probe architecture preserves high bandwidth while providing improved connectivity with low loading. The Z distributed attenuator topology feeding an active probe amplier.
The Z-Active p from the amplier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal delity problems. However this architecture maintains high DC input resistance and presents a higher AC impedance than previous probe architectures. It accomplishes this while providing signicant length between the probe body and the probe best of both worlds: high DC impedance like existing active probes and the stable high-f reque ncy loading of Z
Signal Fidel
You ca n b e c o n dent in the signal delity of your measurements because the Z-Active
High Bandwidth
Excellent Step Response
Low Loading
High CMRR
Extended Linear Dynamic Range
Extended Linear Dynamic Range
Many of today’s logic signals and serial bus signals require the capability to me asure up to several volts peak to peak. These voltage levels may
-Active architecture is a hybrid approach composed of a
robes use a tiny passive probe tip element that is separa te
attachment point to the DUT. This architecture provides the
probes.
0
ity
architecture provides:
easily be viewed with the Z-Active architecture probes (P7380A, P7360A, and P7340A) with the extended linear dynamic range. With a 2.0 V linear dynamic measure DDR II and III, Firewire 1394b, and PCI-Express I and II signals at reduced noise levels. In addition the 25x attenuation setting’s linear dynamic input voltage range can be used up to 5.0 V larger signal swings found during transition times.
input range at the 5x attenuation setting, you can accurately
for accessing even
p-p
p-p
Connectivity
The Z-Active probe design allows the probe to easily switch between soldered, handheld, or xtured applications.
This family of probes uses Tip-Clip™ assemblies, an interchangeable probe tip system that enables customers to congure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes. The several lengths and variable spacing of the assemblies provide exibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday’s solder-in probe can become Tuesday’s handheld tool, simply by switching tips.
Value
The combin ation of the Z-Active architecture and the Tip-Clip assemblies provide superior signal delity at a cost-effective price. The inexpensive Tip-Clip assemblies enable full-performance solder connections at a very low price per connection. Over the life of a probe this can add up to signicant savings in the cost of operation.
Performance You Can Count On
Depend on addition to industry-leading service and support, this product comes backed by a one-year warranty as standard.
Tektronix to provide you w ith performance you can count on. In
2 www.tektronix.com
Characteristics
Z-Active™ Differential Probe Family — P7313 • P7380A • P7360A • P7340A
Characteristic
Bandwidth (Typical) >4 GHz >6 GHz >8 GHz >12.5 GHz Rise Time (10%-90%)
(Guaranteed) Rise Time (20%-80%) (Typical) Attenuation 5x or 25x, user selectable Differential Input Range ±1.0 V (5x)
Linearity Error for Differential Input Dynamic Range (Typical)
Operating Voltage Window Offset Voltage Range DC Input Resistance 100 k AC Loading (Differential Z Noise
CMRR
Nondestructive Input Range ±15 V Interface TekConnect Cable Length
)>290 >200 Ω
min
P7340A P7360A P7380A P7313
>50 dB >35 d >20 d
®
<55 ps
at 1 MHz Bat1GHz Bat8GHz
±0.625 V (5x)
±0.25% for -0.5 V to +0.5 V (5x)
±0.75% for -0.625 V to +0.625 V (5x)
±0.5% for -1.6 V to +1.6 V (25x) ±1.0% for -2.0 V to +2.0 V (25x)
>50 dB >35 d >20 d
>15 d
<100 ps <70 ps
<70 ps <50 ps <35 ps <25 ps
±2.5 V (25x)
±0.5% for -0.5 V to +0.5 V (5x)
±1.0% for -0.75 V to +0.75 V (5x)
±2.0% for -1.0 V to +1.0 V (5x) ±0.5% for -1.5 V to +1.5 V (25x) ±1.0% for -2.5 V to +2.5 V (25x) ±2.0% for -3.0 V to +3.0 V (25x)
+5.0Vto-3.0V +4.0Vto-3.0V
+4.0 V to -3.0 V
<31 nV/Hz (5x)
<75 nV/Hz (25x)
at 1 MHz
>50 dB
Bat1GHz
>35 d
Bat4GHz
>20 d
1.5 m 1.5 m 1.2 m 1.2 m
>50 dB >35 d >20 d
at 1 MHz Bat1GHz Bat6GHz
<40 ps
±2.0 V (25x)
at 1 MHz Bat1GHz Bat6GHz
Bat12.5GHz
Ordering Information
P7313
>12.5 GHz Z-Active Differential Probe for TekConnect®Interface.
P7380A
>8.0 GHz Z-Active Differential Probe for TekConnect®Interface.
P7360A
>6.0 GHz Z-Active Differential Probe for TekConnect®Interface.
P7340A
>4.0 GHz Z-Active Differential Probe for TekConnect®Interface.
All Include: One-year warranty, plus see Standard Accessories table.