Atec P7360 User Manual

Z-Active™Differential Probe Family
P7313 • P7380 • P7360
Z-Active™Probing Architecture Leads the Way for High-speed Probing Applications
Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture pre­serves high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier. The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However, this architecture maintains high DC input resistance and presents a higher AC
impedance than previous probe architec­tures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high frequency loading of Z
probes.
0
Signal Fidelity
You can be confident in the signal fidelity of your measurements because the Z-Active architecture provides:
High bandwidth
Excellent step response
Low loading
High CMRR
Features & Benefits
Signal Fidelity
– >12.5 GHz Bandwidth
(P7313 Only, Typical)
– >8.0 GHz Bandwidth
(P7380 Only, Typical)
– >6.0 GHz Bandwidth
(P7360 Only, Typical)
Low Probe Loading
– DC Input Resistance
– AC Loading
–Z
Versatility
– Make Differential or Single-
ended (Ground Referenced)
Measurements – Solder Down Capability – Handheld Probing with
Variable Spacing and
Compliance (>8 GHz) – Fixtured Probing
Interchangeable Tip-Clip Assemblies
– Connect to a Variety
of Devices – Economical
TekConnect®Interface
>200 Out to 10 GHz
min
*1
Applications
Examples Include, but Are Not Limited to:
– PCI-Express I and II, Serial
ATA II, USB 2.0, DDRII,
Rambus, XAUI
*1
For details, please see application note 60W-18344-0,
“Making Single-ended Measurements with
Differential Probes.”
Z-Active™Differential Probe Family
P7313 • P7380 • P7360
Connectivity
This family of probes uses Tip-Clip
assemblies, an interchangeable probe tip system that enables customers to configure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes.
The several lengths and variable spacing of the assemblies provide flexibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday’s solder-in probe can become Tuesday’s handheld tool, simply by switching tips. The Z-Active probe design allows the probe to easily switch between solder, handheld or
Value
The combination of the Z-Active architec­ture and the Tip-Clip assemblies provide superior signal fidelity at a cost-effective price. The inexpensive Tip-Clip assemblies enable full performance solder connections at a very low price per connection. Over the life of a probe this can add up to significant savings in the cost of operation.
fixtured applications.
Characteristics
P7360 P7380 P7313
Bandwidth (Typical) >6 GHz >8 GHz >12.5 GHz Rise Time (10% to 90%) (Guaranteed) <70 ps <55 ps <40 ps Rise Time (20% to 80%) (Typical) <50 ps <35 ps <25 ps Attenuation 5X or 25X, user selectable Differential Input Range ±0.625 V (5X)
±2.0 V (25X) P7380, P7313
±2.5 V (25X) P7360 only Common Mode Input Range +4.0 V to –3.0 V Offset Voltage Range +4.0 V to –3.0 V DC Input Resistance 100 K AC Loading (Differential Z Noise <30 nV/Hz (5X)
CMRR >50 dB at 1 MHz >50 dB at 1 MHz >50 dB at 1 MHz
Non-destructive Input Range ±15 V Interface TekConnect Cable Length 1.5 m 1.2 m 1.2 m
) >290 >290 >200
min
<75 nV/Hz (25X)
>35 dB at 1 GHz >35 dB at 1 GHz >35 dB at 1 GHz >20 dB at 6 GHz >20 dB at 8 GHz >20 dB at 6 GHz
®
>15 dB at 12.5 GHz
Differential Probes • www.tektronix.com/accessories