Atec P5205, P5210 User Manual

High Voltage Differential Probes
P5200 • P5205 • P5210
Features & Benefits
Bandwidths Up to 100 MHz Up to 5,600 V Differential
(DC + pk AC) Up to 2,200 V Common (RMS) Overrange Indicator Safety Certified Switchable Attenuation Switchable Bandwidth Limit
Applications
Floating Measurements Switching Power Supply Design Motor Drive Design Electronic Ballast Design CRT Display Design Power Converter Design
and Service Power Device Evaluation
P5205.
The P5200 can be used with any oscillo­scope and enables users to
safely make
measurements of floating circuits with their oscilloscope grounded. The P5200 Active Differential Probe converts floating signals to low-voltage ground referenced signals that can be displayed safely and easily on any ground referenced oscilloscope.
WARNING: For safe operation, do not use
the P5200 High Voltage Differential Probe with oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix TPS2000 Series oscilloscopes and THS700 Series oscilloscopes. The P5200 High Voltage Differential Probe requires an oscilloscope or other measurement instrument with grounded inputs. The P5210 is a Differential Probe that is capable of measuring floating voltages up to 5,600 V (DC +pk AC)
safely and has
a bandwidth up to 50 MHz. It is supplied with two sizes of hook tips and has an
P5200.
P5210.
High Voltage Differential Probes
P5200 • P5205 • P5210
overrange visual and audible indicator which warns the user when they are exceeding the linear range of the probe. It can be used with Tektronix TEKPROBE
interface oscilloscopes directly or with any
oscilloscope with the use of the 1103
®
TEKPROBE
Power Supply. The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V
differential probe can measure safely voltages in IGBT circuits such as motor drives or power converters. It is specifically designed to operate on Tektronix oscillo­scopes with TEKPROBE interface.
Characteristics
Specifications P5200 P5205 P5210
Bandwidth (–3 dB) 25MHz 100 MHz 50 MHz Differential Mode Voltage 1000 V CAT II 1000 V CAT II 4400 V
(RMS or DC) (between positive and negative input leads)
Differential Mode Voltage 1300 V 1300 V 5600 V
*1
(between positive
(Peak) and negative input leads)
Common Mode Voltage (RMS or DC 1000 V CAT II 1000V CAT II 2200 V CAT II + Pk AC) (between positive lead and 600 V CAT III 600 V CAT III 1000 V CAT III ground or negative lead and ground)
Attenuation (switchable) 50X/500X 50X/500X 100X/1000X CMRR at 60 Hz/1 MHz (typical) 80 dB/50 dB 80 dB/50 dB 80 dB/50 dB Input R (each input) 4 MΩ 4 MΩ 8 MΩ Input C (each input) 7 pF 7 pF 7 pF Power Source AC wall adapter TEKPROBE Power Supply TEKPROBE Power Supply Safety (all) UL3111-1/CSA1010.1/CSA1010.2.031/IEC61010-2-031/EN61010-2-031 Compatible Products All
*1
The RMS value of the waveform shall not exceed the Common Mode Voltage (RMS) for either lead.
*2
TDS7154B, TDS7254B, TDS7404B, TDS6404, TDS6604, CSA7154, and CSA7404B require a TCA-1MEG Buffer Amplifier.
*3
WARNING: For safe operation, do not use the P5200 High Voltage Differential Probe with oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix TPS2000 series oscilloscopes and THS700 series oscilloscopes. The P5200 High Voltage Differential Probe requires an oscilloscope or other measurement instrument with grounded inputs.
*3
TDS400/500/600/700/ TDS400/500/600/700/
TDS3000B/5000B/6000B
*2
/7000B*2/ TDS3000B/5000B/6000B*2/7000B*2/
CSA7000B*2and 11000 Series CSA7000B*2and 11000 Series
High Voltage Differential Probes • www.tektronix.com/accessories
2
Loading...
+ 2 hidden pages