Atec OC60D, OC60A, OC60TCDE, OC60TCVDE User Manual

OC60D / OC90D
60 / 90 kV Liquid Dielectric Test Sets with Manual Control
Hipotronics OC Series digital liquid dielectric

test sets accurately and reliably test the dielectric strength of insulating liquids used in a wide variety of electric apparatus. The safe and easy operation has made Hipotronics OC series the industry standard for decades.
The OC Series is designed to meet testing specifications in all parts of the world and test cells are available for ASTM D877, ASTM D1816 and IEC
156. The rugged yet lightweight and portable design ensures years of trouble-free operation both in the field and in the laboratory.
The Hipotronics OC series has three pre­programmed rates of voltage rise and automatic termination of voltage upon sample breakdown. A digital memory kilovoltmeter automatically retains the breakdown voltage reading until it is manually reset.
Features
; Lightweight, portable design ; Rugged and reliable ; Output voltages to 60 kV or 90 kV ; Tests insulating oils per ASTM and IEC
specifications
; Automatic HV shutdown at breakdown ; Digital memory kilovoltmeter ; Meter accuracy ± 2% F.S. ; One piece construction with safety interlocked
HV section ; Test cells available for ASTM D877 testing, or
ASTM D1816 & IEC 156 testing
Benefits
Multi-purpose - because of its compact design it’s
easily useable in the field as well as in the factory. Sturdy and Reliable - The OC series of testers have
a long and trouble free life; prove n by over 40 years of industry wide use.
Safe and Easy - The interlocked HV secti on and the integrated controller allow your operators to test safely and easily.
Applications
Testing of insulating liquids in:
Î Transformers Î Bushings Î Switchgear Î Capacitors Î Hydraulics
Subject to technical modifications without notice. OC60/90D-DS / 08.2003
Technical Specifications
General
Output Voltage 0 - 60 kV Input Voltage - A 120 V, 60 Hz Meter Accuracy + 2% of full scale Input Voltage - B 220 V, 50/60 Hz
Weights and Dimensions (W x H x D, net weight, ship weight) OC60D 16" x 13" x 15" (41 x 33 x 38 cm) 69 lbs (31 kg) 74 lbs (86 kg)
OC90D 30" x 12" x 17" (76 x 30 x 43 cm) 122 lbs (55 kg) 190 lbs (86 kg) TCDE 6" x 4" x 3" (15 x 10 x 8 cm) 2 lbs (1 kg) 5 lbs (2 kg) TCVDE 6" x 6" x 6" (15 x 15 x 15 cm) 5 lbs (2 kg) 10 lbs (5 kg) TCVDE90 13" x 6" x 6" (33 x 15 x 15 cm) 11 lbs (5 kg) 20 lbs (9 kg) OCCM-E 6" x 6" x 6" (15 x 15 x 15 cm) 4 lbs (2 kg) 8 lbs (4 kg)
Scope of Supply
Control Panel
Qty. 1 OC60D or OC90D Oil Tester Qty. 1 Standard Line Cord, 7.5 ft (2.3 m) Qty. 1 Operations Manual & Calibration Certificate
Ordering Information
System
Oil Tester, Digital 60 kV OC60D-A, OC60D-B Oil Tester, Digital 90 kV OC90D-A, OC90D-B
Accessories
Digital Calibration kV meter and ramp rate meter. A 0.5 inch digital display, molded epoxy case, with 2% accuracy at full scale. The adapter for the OC90 is included.
Spare parts kit
The TCDE test cell is equipped with two one-inch diameter flat disc electrodes; one is adjustable to provide the desired gap via a set­screw. A standard 0.1 inch gap gauge is supplied. The TCDE is used to test at 3000 v/s rate of rise according to ASTM D877. For use with OC60’s.
The TCVDE test cell is equipped with a motor-driven circulating system
0.08 inch and 0.04 inch gap gauges, and two VDE electrodes, one is adjustable to provide the desired gap. The TCVDE is used to test according to ASTM D1816. For use with OC60’s.
The TCIEC test cell is similar to the Model TCVDE cell but without a motor. For use with OC60’s.
OCCM-E
SPK1-OC60D SPK1-OC90D
TCDE
TCVDE
TCIEC
Test Cells
OCCM-E
TCDE ASTM D877
TCVDE ASTM D1816
The TCCE90 test cell has VDE (mushroom) electrodes and a motor driven circulating system for testing to ASTM D1816. For testing to ASTM D877, disc electrodes (included) with 0.1 inch gap gauge may be substituted. Only for use with OC90’s.
European Contact Locate your local USA Contact
Haefely Test AG
Lehenmattstrasse 353 CH-4028 Basel Switzerland + 41 61 373 4111 + 41 61 373 4912
| sales@haefely.com
Subject to technical modifications without notice. OC60E-DS / 08.2003
sales representative at
www.high-voltage-hubbell.com
TCCE90
TCCE90 ASTM D1816 and ASTM D877
Hipotronics Inc.
1650 Route 22
PO Box 414
Brewster, NY 10509 USA
+ 1 845 279 8091
+ 1 845 279 2467
| sales@hipotronics.com