nsg 437 esd
high performance with basic features
The NSG 437 simulator is designed to sit comfortably in the operator’s hand, with current operating conditions constantly displayed and clearly visible. The simulator is ergonomically designed to be held easily for long duration test procedures.
The touch panel display with its keypad for parameter settings shows the precise functional and test data at any moment. All essential functions and actual status are displayed, with user-selectable language for convenient and safe operation worldwide.
Pre-programmed settings for IEC/EN 61000-4-2 and ISO 10605 ensure that the simulator is automatically set up correctly. The menu with last settings automatically comes up again after shut-down of a test sequence.
Air- and contact-discharge
up to 30 kV
Light version featuring un-
compromised test performance
standards (IEC, ANSI, SAE, ISO) Touch panel display controls Easily and quickly interchange-
able network modules Wide range of accessories
(HV networks, tips, adapters)
Thanks to stabilized HV output the NSG 437 ESD simulator comprehensively fullls virtually all interna­tional standard requirements. Based on over 20 optional discharge networks, the NSG 437 can also meet any of today’s automotive manufacturers’ standards.
NSG 437 generates pulses from 200 V to 30 kV, both in air- and contact-discharge operation. The simula­tor is simple, convenient and safe to use. The whole range of parameter setting possibilities, including polarity selection, counter functions and breakdown detection, remains fully available up to the maximum discharge voltage.
The simulator contains a threshold detector to eliminate faulty discharge counts over its wide operating voltage range. Only valid HV discharges are indicated. When discharges are detected, the counter or preset counter is incremented or decremented respectively – a particularly useful feature for long test runs. The detection feature can be switched off when testing EUT’s with non-conductive surfaces, such as plastic housings.
A wide range of discharge networks and tips fullls the high demand for different test applications and can be exchanged. Completed by a wide selection of rigid and exible discharge tips, any application
is possible. Molded HV discharge networks in solid cases eliminate internally ionization and leakage current effects. Selected combinations of RC components guarantee wave shape parameters to be within tolerances. Discharge network modules with resistance values from zero ohms combined with capacitances up to the nF-range can be simply pushed into place.
Automatic self-calibration of the NSG 437 simulator is performed at ever y start-up. This procedure
runs up to max. voltage in either polarity, thus giving condence, that test levels are maintained within
tolerances.
nsg 437 esd
high performance with basic features
Technical specifications
Description: Compact ESD simulator with microprocessor based, large touch-
sensitive LCD panel, built-in HV relay for contact-discharge, mains operation
Basics: Discharge pistol, high voltage base unit, mains power supply
adapter, (100 to 250 VAC), discharge network 150 pF/330 Ω, air-
and contact-discharge tips, grounding cable, user manual
Pulse data: Standard: Conforms to IEC/EN 61000-4-2 (2001)
Special: Interchangeable networks for other standards
Pulse networks: Network 150 pF/330 Ω as per IEC/EN 61000 -4-2 (included)
Optional ISO 10605 networks 330 pF/330Ω 150 pF/2 kΩ and 330 pF/2 kΩ
Range of RC-networks for other standards: R = 0 Ω to 20 kΩ C = 50 to 2000 pF
Discharge: Air-discharge: 200 V to 30 kV (in 100 V steps)
Contact-discharge: 200 V to 30 kV (in 100 V steps)
Discharge tips: Ball and point as per IEC and specials; exchangeable by threaded
cap Charging voltage measurement: kV, accuracy better than ±5% (stabilized) Discharge detection: Air-discharge only: indicated by the kV symbol being displayed in
inverse, also acoustically in the single‘s operating mode.
Threshold level on/off. Holding time: > 5 s (charging voltage ±5%)
Charge resistor: 50 MΩ
Triggering: Trigger button in hand-grip Operation: Via touch panel and microprocessor Discharge modes: Air-discharge/contact-discharge Polarity: Positive, negative/automatic change Operating modes: Single/repetitive, Pulse counter 0 to 9999
Pre-select counter 0 to 9999
Repetition:
- 0.5/1/5/10/20 or 25 Hz (air)
- 0.5/1/5/10 or 20 Hz (contact)
- Continuous operation Auto-shut-off: After 15 minutes idle time (without loss of the test parameters) Display: LCD panel showing: charging voltage, breakdown event, polarity,
air-/contact-discharge, counter/preselect counter content
Weight: Discharge pistol (w/o cable): 1.2 kg (2.6 lbs) approx.
Base unit: 5.7 kg (12.6 lbs) approx.
Ambient conditions: Operation:
+5 to +40°C 20 to 80% r.h. (non-condensing)
Teseq AG Nordstrasse 11F 4542 Luterb ach Swit zerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales@tese q.com www.teseq.com