Modular, expandable system
Surge voltage to 6.6 kV for over-
testing
Easy to use 7” color touch screen
IEC and ANSI coupling methods
TA (Test Assistance) provides fast
standard test settings
Parameters can be changed while
test is running
Wide range of optional test
accessories
High accuracy switching techno-
logy meets ANSI coupling require -
ments
Teseq’s new NSG 3060 conducted immunity generator takes the proven, user-friendly design of
the highly successful Modula series to a new level. This innovative design uses modular architecture
to provide a versatile system that can be confi gured for basic testing needs and expanded to meet the
needs of sophisticated test laboratories.
Designed to fulfi ll requirements for CE mark and ANSI C62.41 testing, the NSG 3060 performs
tests for Combination wave surge, Ring wave and Electrical Fast Transient (EF T) pulses as well as Power
Quality Testing (PQT). Ex tensive expansion capabilities enable the system to be confi gured for a much
broader range of applications.
New pulse generator modules can be added to the original system quickly and easily with
the NSG 3060’s unique “Master-Slave” concept. This technology allows individual pulse modules to be
calibrated separately with the calibration data and correction factors stored on the slave controller. New
modules can be installed with no need to return the entire system for calibration.
Using state of the art components, the self-contained modules set new standards with respect
to switching and phase accuracy and exceed the existing standards’ requirements. With its powerful
processors, the NSG 3060 can completely fulfi ll the unique coupling requirements specifi ed by ANSI
C62.41. This standard requires that the pulse amplitude be adjusted for the phase position of the pulse
on the AC mains, and for the amplitude of the mains voltage.
A 7” to uch pa nel di spla y wit h su per b contr a s t and co lor is the most striking feature of the new NSG
3060. For fast and effi cient data entry, input devices include an integrated keyboard and a thumbwheel
with additional keys for sensitivity adjustment.
The user-friendly graphic display speeds test setup. Each parameter’s value is highly visible and
all settings can be quickly selected and modifi ed with the generously sized touch input buttons. A stylus
is not necessary, and ramp functions are programmed quickly and easily. Multi-step test procedures can
be created and their sequence or parameter values changed easily.
With Expert Mode users can make manual parameter changes using the thumbwheel while a
test is under way, providing an effective and fast method for identifying critical threshold values.
The Test Assistance (TA) function allows users to initiate standardized test with just a few “clicks”
to achieve quick, reliable results in a development environment.
An easily accessible SD memory card all ows fi rmw are down loa ds to be per forme d qui ckl y and tests
to be sa ve d. In th e ra re case that sto rage sp ac e is not su f fi cien t, the ca rd can be rep laced by a comme rcially available SD memory card and existing test fi les can be easily copied onto the larger SD card.

Combination wave pulse 1, 2/50 - 8/20 µs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5 and ANSI (IEEE) 62.41
Teseq AG
Nordstrasse 11F 4542 Luterbach Sw itzer land
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com w ww.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Parameter Value
Pulse voltage (open circuit): ±200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit): ±100 A to 3.3 kA
Impedance: 2/12 Ω
Polarity: positive / negative / alternate
Pulse repetition: 5* to 20 s, up to 600 s (in 1 s steps)
* derated depending on selected pulse voltage and
EUT supply voltage
Test duration: 1 to 9999 pulses, continuous
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling: ANSI / IEC / external
Th e NSG 3 060 ha s an Et h ernet p o r t fo r ex ter n al PC c o ntrol. The Windows-based control software
simplifi es test programming and allows compilation of complex test sequences with diverse pulse types.
Test reports can be generated during the test operation, allowing the operator to enter observations as
the test progresses and increasing the effi ciency of long-term tests.
Ringwave 0.5 µs/100 kHz
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Parameter Value
Pulse voltage (open circuit): ± 200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit): ±16.6 to ±550 A, ±10%
±6.6 to ±220 A, ±10%
±1 to ±33 A, ±10%
Impedance: 12/30/200 Ω
Polarity: positive / negative / alternate
Pulse repetition: 5* to 20 s, up to 600 s (in 1 s steps)
* derated depending on selected pulse voltage and
EUT supply voltage
Test duration: 1 to 9999 pulses, continuous
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling: ANSI / IEC / external
The NSG 3060 performs tests according to the following specifi cations:

Teseq AG
Nordstrasse 11F 4542 Luterbach Sw itzer land
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com w ww.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Parameter Value
Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit
±100 V to 2.4 kV (50 Ω matching system)
Burst frequency: 100 Hz to 1000 kHz
Polarity: positive / negative / alternate
Repetition time: 1 ms to 4200 s (70 min)
Burst time: 1 µs to 1999 s, single pulse, continuous
Test duration: 1 s to 1000 h
Phase synchonization: asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling: ANSI / IEC / external
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Dips & drops
conforms to IEC/EN 61000 -4-11
Parameter Value
Dips & drops: From EUT voltage input to 0 V, 0%
Uvar with optional variac: depending on model ( VAR 650x)
Uvar with step transformer: 0, 40, 70, 80% (INA 650x)
Peak inrush current capability: 500 A (at 230 V)
Switching times: 1 to 5 μs (100 Ω load)
Event time: 20 µs to 1999 s, 1 to 99’999 cycles
Test duration: 1 s to 70’000 min, 1 to 99’999 events, continuous
Repetition time: 40 µs to 35 min, 1 to 99’999 cycles
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
Variation test
conforms to IEC/EN 61000 -4-11
Parameter Value
Uvar with optional variac: 0 to 265 V (in 1 V steps), 0 to 115% (in 1% steps)
Repetition time: 1 ms to 35 min, 1 to 99’999 cycles
Test duration: 1 ms to 5 s, 1 to 250 cycles (50 Hz);
1 to 300 cycles (60 Hz), abrupt
Repetition time: 10 ms to 10 s; 1 to 250 cycles (50 Hz), 1 to 300 cycles (60 Hz)
Test duration: 1 s to 99’999 min, 1 to 99’999 events, continuous
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)

Teseq AG
Nordstrasse 11F 4542 Luterbach Sw itzer land
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com w ww.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Parameter Value
Field: 1 to 1200 A/m (in 1 A/m steps)
Polarity: positive / negative / alternate
Repetition time: 5 s to 10 min (in 1 s steps)
Impedance: 2 Ω
Coil factor 0.01 to 50.00
Test duration: 1 to 9’999 pulses; continuous
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
Field: 1 to max. 40 A/m (in 1 A/m steps)
Frequency: 50/60 Hz
Coil factor: 0.01 to 99.99
Test duration: 1 to 9’999 pulses, continuous
Pulsed magnetic field in conjunction with INA 753 and INA 701 or 702
conforms to IEC/EN 61000 -4-9
Power magnetic field in conjunction with MFO 6501 / MFO 6502 and INA 70x
conforms to IEC/EN 61000 -4-8

Teseq AG
Nordstrasse 11F 4542 Luterbach Sw itzer land
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com w ww.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Parameter Value
Instrument supply: 230/115 VAC
Decoupling attenuation: Remanent pulse 15% max.
Mains side crosstalk 15% max.
Mains decoupling: 1.5 mH 0% + 35%
Connections: Pulse input from generator
Cable connector for EUT supply
Power inlet for CDN
EUT supply: 1-phase
EUT VAC: 24 to 270 Vrms, 50/60 Hz (phase - neutral), 400 Hz max.
EUT VDC: 0 to 270 VDC
EUT current 1 x 16 Arms continuous (temperature controlled)
1 x 25 Arms for 30 min
EFT (Burst) Standard coupling all lines to ref ground (GND)
IEC/EN 61000-4-4 and ANSI (IEEE) C62.41
L, N, PE ref GND
Any lines and combinations to ref GND:
L ref GND
N ref GND
PE ref GND
L, N ref GND
L, PE ref GND
N, PE ref GND
Combination wave pulse: IEC/EN 61000-4-5
Line to line (2 Ω)
N L / L PE / N PE
Lines to ground (12 Ω)
L PE / N PE / L, N PE
Combination wave & ring wave: ANSI (IEEE) C62.41
Basic 1 & 2 L, N PE & L N
Supplemetal 1 & 2 N PE & L PE
Diagnostic 1 & 2 N, PE L & L, PE N
Ring wave: IEC/EN 61000 -4-12
12/30/200 Ω
N L / L PE / N PE
L PE / N PE / L, N PE
PQT: Dips & drops to phase L
Coupling networks CDN 3061

Teseq AG
Nordstrasse 11F 4542 Luterbach Sw itzer land
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com w ww.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Dimensions/weight
Dimensions NSG 3060 W x H x D: 449 (17.7”) x 328 (12.9”; 7 HU) x 565 mm (22.2”)
Weight NSG 3060: 22 kg (48.5 lbs)
Dimensions CDN 3061-C16 WxHxD: 449 mm (17.7”) x 226 mm (8.9”; 5 HU) x 565 mm (22.2”)
Weight CDN 3061-C16: 20 kg (44 lbs)
Options
CDN 3063-C32 Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A
CDN 3063-C63 Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A
CDN 8014/8015 Capacitive coupling clamp for burst
CDN 163 Burst coupling network 100 A per phase (coupling all to ref ground)
CDN 117/118 Coupling networks for signal-/data lines (surge)
CAS 3025 Burst/EFT verifi cation set
MD 200A Voltage differential probe 7 kV
MD 300 Current probe 5 kA
Accessories for IEC/EN 61000-4-11
INA 6501 Manual step transformer, 16 AAC, 0/40/70/80%
INA 6502 Automatic step transformer, 16 AAC, 0/40/70/80%
VAR 6501 Automatic variable transformer, 7.5 A
VAR 6502 Automatic variable transformer, 2 x 16 A
VAR 6503 Manual variable transformer, 7.5 A
Accessories for IEC/EN 61000-4-8/-4-9
MFO 6501 Manual magnetic fi eld option -4-8
MFO 6502 Automatic magnetic fi eld option -4-8
INA 701 Magnetic fi eld coil 1 x 1 m; with MFO max. 3.6 A/m -4-8;
Surge* max. 1200 A/m -4-9
INA 702 Magnetic fi eld coil 1 x 1 m, with MFO max. 40 A/m -4-8;
Surge* max. 1200 A/m -4-9
*) Pulse shape adapter INA 753 needed to surge generator