Atec NSG2050 User Manual

System 2050 is a highly versatile, modular, multi-role EMC test facility adaptable to meet a wide variety of test specifications, from compliance with basic national and international standards, through detailed design characterisation to compliance with manufacturers’ own, more exacting EMC specifications. Its modularity offers each test lab a configuration to suit its test needs cost-effectively while remaining expandable so that, as test needs grow and change, System 2050 can be extended accordingly, thereby protecting investment.
Conducted Immunity EMC Test System
Modular concept
Wide range of pulse networks conforming to IEC, ANSI, FCC etc
Industrial/telecom test applications
Professional test management software
Technical Specifications
Power: 100 to 240Vac, 50/60Hz
Microprocessor control recognises all system elements
Operation with keypad and display
Pulse output via 10kV connectors
Oscilloscope trigger output
Remote pulse trigger output
Voltage / current monitor
Peak current detector
EUT fail input with program control
Line synchronization input
End of test signal
NSG 2050
Safety interlock
Emergency stop to IEC safety regulations
Interface to coupling networks
RS 232 computer interface
Table top unit or rack mount
Dimensions 310 x 449 x 510mm
Weight approx 20kg
Interfaces extension chassis for pulse and control
Houses one PNW at any time in system mainframe
Houses up to five PNW at a time with extension chassis
System 2050
UKAS Calibration option
System 2050
INA 260
SPECIFIC ACCESSORIES
LINE COUPLING
SIGNAL / DATALINE COUPLING
PNW 2050
6.6 kV
1.2/50-8/20
Special:
8 kV
CDN
131/133
CDN 117
Magnetic
field
PNW 2051
6.6 kV 6.6 kV
0.5/700 10/700
CDN 118
PULSE FORM
STANDARD
IEC 61000-4-5 IEEE C62.41 (IEC 61000-4-9)
IEC 61000-4-5 CCITT K 17
INA 122
Test Box
PNW 2052
100 kHz
Ringwave
CDN
131/133
CDN 117
IEEE C62.41
NSG 2050
PNW 2053B
3 kV/ 1.6 kV
2/10 10/160 10/560
9/720
CDN 141
FCC Part 68
PNW xxxx
PNW 2055
4.4 kV
1.2/ 50-8 /20 16 A CDN
INA
2055
CDN 117
IEC 61000-4-5 IEEE C62.41
INA 2050
2 Slot
Extension
PNW 2056
4 kV/ 2.7 kV
100 kHz
1 MHz
CDN
131/133
CDN 117
IEC 61000-4-12
INA 2050
Extension
PNW 2003
PQT 16 A
NSG 642
VARIAC
IEC 61000-4-11
2 Slot
PNW 2225
4.8 kV Burst
16 A CDN
CDN
133/153
CDN 126
IEC 61000-4-4
Conducted Immunity EMC Test System
Intelligent Mainframe
At the heart of System 2050 is the NSG 2050 mainframe unit, consisting of a micro-processor based control unit, a high voltage source and accommodation for user selected plug-in pulse networks. Each of the System 2050 plug-in modules and extension units comes complete with its own firmware, so that the system automatically recognises its presence and presents the user with the appropriate software menus and front-panel options. Intelligent control is effected either through the front panel controls and display or via a PC. Further, System 2050 is designed for inter-compatibility, using open­architecture principles and modular Windows control software. As such, it can be combined seamlessly with any of Schaffner's specialist test and measurement instrumentation and with third party products, including radiated interference test equipment, in a complete ProfLine test system to meet the most demanding test needs.
A Complete Conducted Immunity Test System
System 2050 offers a complete set of plug-in networks for full compliance testing to basic, generic and product standards, for single-phase and three­phase power lines as well as data and telecom lines. The mainframe unit and three plug-in networks (PNW 2055 surge and PNW 2225 fast transient pulse
generators and PNW 2003 a power quality module) make up a complete, integrated system for testing susceptibility to conducted interference on single-phase power lines. System 2050 may include just one or several modules and each of these provides a self-contained test facility that requires no external coupling unit for single-phase power line immunity tests to the basic standard. As requirements change in the future, System 2050 remains expandable with further networks and extensions for new applications.
PNW 2055
is a basic surge generator complying with IEC 61000-4-5 that provides a hybrid surge pulse of 1.2/50µs - 8/20µs, with built-in coupling for single-phase equipment up to 16A.
PNW 2225
generates burst pulses according to IEC 61000-4-4 and offers a range of additional test parameters. It includes a built-in processor-controlled 16A coupling network.
PNW 2003
is a versatile power network quality simulator which generates drop-outs, dips, interruptions and variations. The correct functions for compliance testing are pre-programmed and no external device is needed.
An additional wide range of high current, high voltage pulse generator plug-in networks and external single-and three­phase extension units is available for more demanding industrial test applications. These can be used to create a complete user-defined system for testing to, and beyond, the full IEC, ANSI, IEEE, VDE standards and European Norms.
Technical Specifications 2055 / 2225 / 2003xx
PNW 2055 Hybrid pulse 1.2/50µs - 8/20µs, 200V to 4400V IEC 61000-4-5
up to 2200A EN 50082
Impedance 2and 12 EN 61000-4-5 Pulse rep 10s to 10000s ANSI/IEEE C62.41 Coupling built in coupling network, 20V to 230Vac, 16A
synch or asynch to power line
PNW 2225 Burst pulse 5/50ns, 200V to 4800V IEC 61000-4-4
Frequency 100Hz to 1MHz EN 50082 Spikes 1 to 250 per package and continuous EN 61000-4-4 Coupling built in coupling network, 12V to 250Vac, 16A
switched output for coupling clamp
PNW 2003 Power quality drop out 2ms to 99s IEC 61000-4-11
dips to 40% and 70% of U nominal. EN 50082 synch or asynch to power line EN 61000-4-11 variable dips and voltage with external variac
EUT power 12V to 250V, 16A nominal, ac and dc
System 2050
Conducted EMC Test System
Technical Specifications 2050 / 2051 / 2052 / 2056 / NSG 642xx
PNW 2050 Hybrid pulse 1.2/50µs - 8/20µs, 200V to 6600V
up to 3300A
Impedance 2an 12 Pulse rep 10s to 10000s
PNW 2051 Telecom 10/700µs and 0.5/700µs, 200V to 6600V
up to 440A
Impedance 15and 40 Pulse rep 10s to 10000s
PNW 2052 Ring wave 0.5µs/100kHz, 200V to 6600V
up to 550A
Impedance 12, 30and 200 Pulse rep 10s to 10000s
PNW 2056 Damped osc. 0.5µs/100kHz up to 4000V
75ns/100kHz up to 2700V 75ns/1MHz up to 2700V
Rep rate 40Hz at 100kHz, 400Hz at 1MHz
NSG 642 Power quality motor driven transformer extension
1 to 280Vac
16A continuous, 25A for 1min. Speed up to 120V/s mechanical 310 x 449 x 510, 35kg approx
PNW 2050
provides high energy hybrid surge pulses of 1.2/50µs - 8/20µs with an extended voltage range as required by IEC, ANSI­IEEE and many other standards. It is used with single- and 3-phase power-line coupling networks or data-line couplers. The network can also be used, in conjunction with an antenna, for pulsed magnetic field testing, e.g. to IEC 61000-4-9.
PNW 2051
provides a 10/700µs pulse, as specified in telecom applications and also required in some industrial electronics standards, e.g. IEC 61000-4-5. For higher test specifications, PNW 2051 also provides the sharper pulse rise time of 0.5µs. The matching pulse networks, required in some applications, are available.
PNW 2052
generates a 100kHz ringwave, as required by the ANSI-IEEE standard. It can be used with external coupling unit CDN 131 or CDN 133 for single-or three-phase testing up to 25A.
PNW 2056
is a high frequency pulse generator which produces damped oscillatory waves of 100kHz and 1MHz with amplitudes up to 4kV.
Coupling Units
A comprehensive range of couplers and extension units is available for single- and three-phase power-line and data-line testing. Full technical details are outlined on page 44.
CDN 131 and CDN 151
are designed to couple surge pulses and fast transient pulses respectively to single-phase power lines. They can be used with all the surge and fast transient pulse generator networks, for testing up to 240Vac and 25A.
CDN 133 and CDN 153
are providing three-phase coupling for tests up to 440Vac (phase to phase) and 25A continuous operation. All combinations of coupling modes are selectable under software control. There are separate inputs for high energy surge pulses and high frequency burst pulses with one common output to the equipment under test.
NSG 642
is an automated variable AC source which can be used as a second supply with the drop-out simulator PNW 2003 to generate a wide range of dynamic voltage variations including over-voltage, ramps and dips. Meets the requirements of IEC 61000-4-11.
Technical Specifications CDN 131 / 133xx
CDN 131 Surge Coupling single-phase coupling network
20V to 230Vac, 50/60Hz
25A continuous, 30A for 0.5 hour Burst Coupling CDN 151 option Mechanical 310 x 449 x 510, 22kg approx
CDN 133 Surge Coupling 3-phase coupling network
3 x 20V to 440Vac, 50/60Hz
25A continuous, 30A for 0.5 hour Burst Coupling CDN 153 option, 3-phase Mechanical 310 x 449 x 510, 32kg approx
System 2050
Conducted EMC Test System
Technical Specifications PNW 2051 / 2053xx
PNW 2051 CCITT 10/700µs and 0.5/700µs, 200V to 6600V
up to 440A
Impedance 15and40 Pulse rep 10s to 10000s
PNW 2053B FCC 2/10µs up to 2600V / 1150A
10/160µs up to 2500V / 220A 10/560µs up to 950V / 110A
9/720µs up to 2500V / 50A
Telecom Test System
A range of specialist telecom test plug-in networks for System 2050 is available for testing to current telecom standards around the world, including CCITT, FCC, IEC, Bellcore and ETSI. There is also a full set of coupling units available, for coupling fast transient and surge pulses to two-wire, four-wire, multi-wire PABX and ISDN lines.
PNW 2051
generates 10/700µs and 0.5/700µs test pulses as used in telecom specs such as CCITT. Normally applied in non-powered test arrangements, it can also be used with coupling networks for powered system tests.
PNW 2053B
provides all pulses required by the new FCC part 68 standard in one device. FCC part 68 specifies the test methods for all classes of terminal equipment in the telecommunication environment. The test arrangement includes a dedicated coupling unit, CDN 141, with a decoupling network for the 2/10µs power line test pulse and coupling facilities for telecom line test applications.
Components’ Test System
Components are often tested in, or close to, the manufacturing area. System 2050 offers the required safety standards and operating flexibility, as well as ready to use adapters. Test sequences are prepared by the system administrator then simply called into operation by the operator. Manipulation errors are avoided and the test results can be recorded automatically. The system can be used as a platform for a wide range of test rigs from a self-contained test bench arrangement, to complex computer controlled set-ups with integration of power sources and measuring equipment.
System 2050