Atec Nortec-500 User Manual

EDDY CURRENT FLAW DETECTORS
Nortec® 500 Series
Features
■ 50 Hz to 12 MHz frequency range
■ Preamplifier (0 or 14 dB)
■ Single Li-Ion battery, choice of two
battery configurations: 2.4 Ahr or 8.8 Ahr
■ Lightweight, 1.2 kg to 1.7 kg
(2.8 lbs to 3.8 lbs) depending on battery configuration
■ 165 mm (6.5 in.) full VGA color LCD
(640 x 480 resolution)
Eddy Current Flaw Detectors
The Nortec 500 Series eddy current flaw detectors incorporate a full range of fea­tures: internal balance coils, VGA output connector (for heads up displays, monitors, and projectors), and a USB interface for rapid information transfer. The Nortec 500 also includes PowerLink, for automatic probe recognition and program set-up.
The Nortec 500 improves on previous Nortec eddy current instruments and is available in four configurations. Each configuration includes a USB port and increased resolution with reduced noise. Internal balance coils allow use of inex­pensive absolute probes without the need for external balance coil adapters. A built­in preamp adds extra gain when needed for difficult tests. VGA output allows for the display to be projected or viewed on a standard computer screen.
The optional remote-null adapter adds convenience by allowing the probe to be nulled and the instrument screen erased from the probe.
Where weight is critical, the smaller battery lightens the instrument to 1.2 kg (2.8 lbs) while keeping the full VGA resolution and display size.
The Nortec 500 delivers basic single fre­quency eddy current inspection including external outputs.
The Nortec 500C adds digital conductivity and coating thickness measurement capa­bility in addition to basic single frequency eddy current inspection.
The Nortec 500S builds on the foundation of the N500C and adds the ability to use rotating scanners.
The Nortec 500D adds dual frequency ca­pabilities to all the functions of the N500S.
■ On-board storage of up to 200 programs
■ On-screen reference memory for
go/no go applications
■ Internal balance loads for single coil
probe support
■ Display Freeze to hold flaw signals
■ PowerLink technology - automatic
probe recognition and instrument set-up
■ Foreign Object Debris (FOD) free case
design
■ VGA output
Optional Accessories
Protective rubber boot: (U8764035) 1020328 Chest harness: (U8140055) EP4/CH External battery charger: (U8767085) 3720308 Extra li-ion battery
2.4 Ahr - (U8902014) 9522195
8.8 Ahr - (U8760012) 0146689
Features 500 500C 500S 500D
Single Frequency Capabilities
Digital Conductivity
Coating Thickness Measurement
Rotating Scanner Support
Spilt Screen Display
Dual Frequency Capabilities
P P P P
P P P
P P P
P P
P P
P
920-079F-EN
Nortec 500, 500C, 500S and 500D Specifications*
General
Dimensions (W x H x D)
Weight
Display
Operating temperature
Humidity 5% to 95%
Classification
Altitude
Hazardous area operation
Probe types
Alarms
Alarm modes
Trace storage
Program storage
Print out
216 mm x 140 mm x 61 mm (8.5 in. x 5.5 in. x 2.4 in.)
1.2 kg to 1.7 kg (2.8 lbs to 3.8 lbs), depending upon configuration
133 mm x 99 mm, 165 mm diagonal (5.25 in. x 3.9 in., 6.5 in.) full VGA color LCD (640 x 480 pixels)
–10 ºC to 55 ºC (14 ºF to 122 ºF)
Based on Class 2 specifications from the MIL-PRF-28800F handbook
Maximum operating and non-operating altitude ­4600 m (15,000 ft)
Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Associa­tion Code (NFPA 70), Section 500, and tested using MIL-STD-810F, Method 511.4, Procedure 1
Absolute and differential in either bridge or reflection configuration. The instrument is fully compatible with Nortec PowerLink probes.
Can be set to trigger on positive or negative box, polar, or sweep alarm settings
1 to 3 box gates, polar, sweep, conductivity, and coating thickness
Up to 200 traces can be stored for recall. The traces can be static or frozen and can contain up to 60 seconds of movement. The traces are stored with the date and time of capture.
Up to 200 instrument set-ups may be stored and recalled. The date and time of storage is recorded with each set-up.
Provides a custom configurable report header containing the display screen data and probe parameters including serial numbers (PowerLink probes only).
Measurements
Frequency range 50 Hz to 12 MHz
Gain
Rotation Variable 0º to 359º in 1º steps
Sweep Variable from 0.005 s to 4 s per division
Low Pass filter 10 Hz to 500 Hz and wide band
High Pass filter Off or 2.0 Hz to 500 Hz, 2 pole response
Built-in preamplifier 5X (14 dB) additional gain.
Probe drive 2 volts, 6 volts, 12 volts
Variable persistence 0.1 s to 5 s
0 dB to 90 dB in 0.1 dB steps. The horizontal and vertical gains may be adjusted separately or together.
Inputs/Outputs
Power
USB port Allows interface with PC and printers
Probe connector 16-pin LEMO and BNC
Analog outputs
Alarm outputs 15-pin analog and alarm output connector
VGA output 15-pin connector
2-pin connector to charge the internal batteries and operate the instrument from AC power
Horizontal and vertical outputs of both F1 and F2. +/– 5 V, 1 V per division (four outputs)
Power
Power requirements
Available batteries 2.4 Ahr Li-ion or 8.8 Ahr Li-ion
Low battery protection
Battery operating time
85 V to 240 V, 50 Hz to 60 Hz. Battery can be charged within the instrument or in an external charger. Charge typically takes 4 hours.
Display bar graph “gas gauge” indicates approxi­mate operating time. A low battery annunciator indicates when approximately 10 minutes of operation time is left.
3 to 8 hours nominal depending on configura­tion and scanner usage
Conductivity (Nortec 500C, 500S, and 500D only)
Frequency 60 kHz or 480 kHz
Digital conductivity display from 0.9% to 110%
Digital conductivity specification
Non-conductive coating thickness
IACS or 0.5 to 64 MS/m. Accuracy within +/– 0.5% IACS from 0.9% to 65% IACS and within +/– 1.0% of values over 62%. Meets or exceeds BAC 5651 specifications.
Can measure non-conductive coating thickness from 0 mm to 0.38 mm (0 in. to 0.015 in.). Accuracy of 0.025 mm (+/– 0.001 in.) over 0 mm to 0.38 mm (0.00 in. to 0.015 in.) range
Scanners (Nortec 500S and 500D only)
Scanner compatibility
Waterfall display
Will operate all current Nortec scanners and many other commercially available scanners
60 sweeps per hole and includes an on screen readout of the distance to the defect from the start of the scan
Dual Frequency (Nortec 500D only)
Frequency extension 50 Hz to 12 MHz
Second frequency
Display
High Pass filter Available in frequency (F1) only
25 Hz to 6 MHz, 2nd frequency is an exact divi­sion of the first frequency in ratios of
Frequency 1 (F1) only, frequency 2 (F2) only, sum of F1 and F2, difference between F1 and F2, split screen with selected combinations of F1 and F2 and mixed frequencies
www.olympus-ims.com
info@olympusNDT.com
48 Woerd Avenue, Waltham, MA 02453, USA, Tel.: (1) 781-419-3900 12569 Gulf Freeway, Houston, TX 77034, USA, Tel.: (1) 281-922-9300
505, boul. du Parc-Technologique, Québec (Québec) G1P 4S9, Tel.: (1) 418-872-1155 1109 78 Ave, Edmonton (Alberta) T6P 1L8
Nortec_500_EN_201102• Printed in the USA • Copyright © 2010 by Olympus NDT.
*All specications are subject to change without notice.
All brands are trademarks or registered trademarks of their respective owners and third party entities.
is ISO 9001 and 14001 certified.