EDDY CURRENT FLAW DETECTORS
Nortec® 500 Series
Features
■ 50 Hz to 12 MHz frequency range
■ Preamplifier (0 or 14 dB)
■ Single Li-Ion battery, choice of two
battery configurations: 2.4 Ahr or 8.8 Ahr
■ Lightweight, 1.2 kg to 1.7 kg
(2.8 lbs to 3.8 lbs) depending on battery
configuration
■ 165 mm (6.5 in.) full VGA color LCD
(640 x 480 resolution)
Eddy Current Flaw Detectors
The Nortec 500 Series eddy current flaw
detectors incorporate a full range of features: internal balance coils, VGA output
connector (for heads up displays, monitors,
and projectors), and a USB interface for
rapid information transfer. The Nortec 500
also includes PowerLink, for automatic
probe recognition and program set-up.
The Nortec 500 improves on previous
Nortec eddy current instruments and is
available in four configurations. Each
configuration includes a USB port and
increased resolution with reduced noise.
Internal balance coils allow use of inexpensive absolute probes without the need
for external balance coil adapters. A builtin preamp adds extra gain when needed
for difficult tests. VGA output allows for
the display to be projected or viewed on a
standard computer screen.
The optional remote-null adapter adds
convenience by allowing the probe to be
nulled and the instrument screen erased
from the probe.
Where weight is critical, the smaller battery
lightens the instrument to 1.2 kg (2.8 lbs)
while keeping the full VGA resolution and
display size.
The Nortec 500 delivers basic single frequency eddy current inspection including
external outputs.
The Nortec 500C adds digital conductivity
and coating thickness measurement capability in addition to basic single frequency
eddy current inspection.
The Nortec 500S builds on the foundation
of the N500C and adds the ability to use
rotating scanners.
The Nortec 500D adds dual frequency capabilities to all the functions of the N500S.
■ On-board storage of up to 200 programs
■ On-screen reference memory for
go/no go applications
■ Internal balance loads for single coil
probe support
■ Display Freeze to hold flaw signals
■ PowerLink technology - automatic
probe recognition and instrument set-up
■ Foreign Object Debris (FOD) free case
design
■ VGA output
Optional Accessories
Protective rubber boot: (U8764035) 1020328
Chest harness: (U8140055) EP4/CH
External battery charger: (U8767085) 3720308
Extra li-ion battery
2.4 Ahr - (U8902014) 9522195
8.8 Ahr - (U8760012) 0146689
Features 500 500C 500S 500D
Single Frequency Capabilities
Digital Conductivity
Coating Thickness Measurement
Rotating Scanner Support
Spilt Screen Display
Dual Frequency Capabilities
P P P P
P P P
P P P
P P
P P
P
920-079F-EN
Nortec 500, 500C, 500S and 500D Specifications*
General
Dimensions
(W x H x D)
Weight
Display
Operating
temperature
Humidity 5% to 95%
Classification
Altitude
Hazardous area
operation
Probe types
Alarms
Alarm modes
Trace storage
Program storage
Print out
216 mm x 140 mm x 61 mm
(8.5 in. x 5.5 in. x 2.4 in.)
1.2 kg to 1.7 kg (2.8 lbs to 3.8 lbs), depending
upon configuration
133 mm x 99 mm, 165 mm diagonal
(5.25 in. x 3.9 in., 6.5 in.) full VGA color LCD
(640 x 480 pixels)
–10 ºC to 55 ºC (14 ºF to 122 ºF)
Based on Class 2 specifications from the
MIL-PRF-28800F handbook
Maximum operating and non-operating altitude 4600 m (15,000 ft)
Safe operation as defined by Class I, Division 2,
Group D, as found in the National Fire Association Code (NFPA 70), Section 500, and tested
using MIL-STD-810F, Method 511.4, Procedure 1
Absolute and differential in either bridge or
reflection configuration. The instrument is fully
compatible with Nortec PowerLink probes.
Can be set to trigger on positive or negative box,
polar, or sweep alarm settings
1 to 3 box gates, polar, sweep, conductivity, and
coating thickness
Up to 200 traces can be stored for recall. The
traces can be static or frozen and can contain
up to 60 seconds of movement. The traces are
stored with the date and time of capture.
Up to 200 instrument set-ups may be stored
and recalled. The date and time of storage is
recorded with each set-up.
Provides a custom configurable report header
containing the display screen data and probe
parameters including serial numbers
(PowerLink probes only).
Measurements
Frequency range 50 Hz to 12 MHz
Gain
Rotation Variable 0º to 359º in 1º steps
Sweep Variable from 0.005 s to 4 s per division
Low Pass filter 10 Hz to 500 Hz and wide band
High Pass filter Off or 2.0 Hz to 500 Hz, 2 pole response
Built-in preamplifier 5X (14 dB) additional gain.
Probe drive 2 volts, 6 volts, 12 volts
Variable persistence 0.1 s to 5 s
0 dB to 90 dB in 0.1 dB steps. The horizontal
and vertical gains may be adjusted separately or
together.
Inputs/Outputs
Power
USB port Allows interface with PC and printers
Probe connector 16-pin LEMO and BNC
Analog outputs
Alarm outputs 15-pin analog and alarm output connector
VGA output 15-pin connector
2-pin connector to charge the internal batteries
and operate the instrument from AC power
Horizontal and vertical outputs of both F1 and
F2. +/– 5 V, 1 V per division (four outputs)
Power
Power requirements
Available batteries 2.4 Ahr Li-ion or 8.8 Ahr Li-ion
Low battery
protection
Battery operating
time
85 V to 240 V, 50 Hz to 60 Hz. Battery can be
charged within the instrument or in an external
charger. Charge typically takes 4 hours.
Display bar graph “gas gauge” indicates approximate operating time. A low battery annunciator
indicates when approximately 10 minutes of
operation time is left.
3 to 8 hours nominal depending on configuration and scanner usage
Conductivity (Nortec 500C, 500S, and 500D only)
Frequency 60 kHz or 480 kHz
Digital conductivity display from 0.9% to 110%
Digital conductivity
specification
Non-conductive
coating thickness
IACS or 0.5 to 64 MS/m. Accuracy within
+/– 0.5% IACS from 0.9% to 65% IACS and
within +/– 1.0% of values over 62%. Meets or
exceeds BAC 5651 specifications.
Can measure non-conductive coating thickness
from 0 mm to 0.38 mm (0 in. to 0.015 in.).
Accuracy of 0.025 mm (+/– 0.001 in.) over
0 mm to 0.38 mm (0.00 in. to 0.015 in.) range
Scanners (Nortec 500S and 500D only)
Scanner
compatibility
Waterfall display
Will operate all current Nortec scanners and
many other commercially available scanners
60 sweeps per hole and includes an on screen
readout of the distance to the defect from the
start of the scan
Dual Frequency (Nortec 500D only)
Frequency extension 50 Hz to 12 MHz
Second frequency
Display
High Pass filter Available in frequency (F1) only
25 Hz to 6 MHz, 2nd frequency is an exact division of the first frequency in ratios of
Frequency 1 (F1) only, frequency 2 (F2) only,
sum of F1 and F2, difference between F1 and
F2, split screen with selected combinations of F1
and F2 and mixed frequencies
www.olympus-ims.com
info@olympusNDT.com
48 Woerd Avenue, Waltham, MA 02453, USA, Tel.: (1) 781-419-3900
12569 Gulf Freeway, Houston, TX 77034, USA, Tel.: (1) 281-922-9300
505, boul. du Parc-Technologique, Québec (Québec) G1P 4S9, Tel.: (1) 418-872-1155
1109 78 Ave, Edmonton (Alberta) T6P 1L8
Nortec_500_EN_201102• Printed in the USA • Copyright © 2010 by Olympus NDT.
*All specications are subject to change without notice.
All brands are trademarks or registered trademarks of their respective owners and third party entities.
is ISO 9001 and 14001 certified.