Fluke Networks’ SimpliFiber® Pro
Optical Power Meter incorporates
new and innovative features to give
technicians a tool that performs and
reports test results like no other
first-line fiber test tool can.
The only way to accurately test
and verify the performance of your
fiber-optic network is with test
equipment designed for the job.
The SimpliFiber® Pro Optical Power
Meter and Fiber Test Kits is a suite
of affordable and easy-to-use fiber
verification test solutions. Today’s
high bandwidth premise networks
heavily rely on fiber-optic
infrastructure. Proper installation
and maintenance of fiber cabling is
imperative to improve technician
productivity and ensure cabling
system performance.
See how Fluke Networks’ suite
of innovative installation and
test solutions improves technician productivity and ensures
cabling system performance.
SimpliFiber Pro is an improved fiber test set
that simplifies and shortens the front-line
testing process by:
• reducing the multiple steps and
using a simultaneous dual-wavelength
testing feature to measure the range of
power levels in just half the time
• allowing for a non-touch solution to
check for a live fiber without having
to plug into ports
• enabling a network technician to do
time-consuming procedures that
normally require a team
SimpliFiber® Pro Optical Power Meter and
Fiber Test Kits provide you with all the tools
you need to help you verify proper installation
and maintain fiber-optic cabling systems.
Available in kits or a la carte, these tools are
simple and effective and provide you with the
capability to measure loss and power levels,
locate faults and polarity issues, and inspect
connector end-faces.
A system approach
SimpliFiber Pro is a product suite that allows
you to match products and functionality to
your needs. SimpliFiber Pro is made up of four
unique fiber platforms: the power meter, the
multimode source, the singlemode source,
TM
and the FindFiber
Each platform has uniquely competitive
features, bundled in convenient kits, to
meet the needs of today’s technicians.
The optical power meter is included in all kits
and is calibrated for accuracy at six different
wavelengths (850, 1300, 1310, 1490, 1550,
1625). The meter features the ability to save
a reference power level, allowing a direct
display of fiber loss. It also has an intuitive
four-button panel, a large LCD display screen,
and a serial port. The meter’s single connec-
tor permits simple network connection and
straightforward reference power measurement.
Interchangeable connector adapters are
available in the most popular connector styles.
Remote ID source.
Technical Data
SimpliFiber Pro makes fiber-link verification and troubleshooting
even simpler.
Page 2
Patch Panel
Fiber Links
SimpliFiber Pro
meter
ID #3
ID #4
ID #5
Figure 1. Using FindFiber mode to locate fibers –
patch panel to wall outlet
Patch Panel
SimpliFiber Pro
meter
Fiber Links
ID #6ID #7ID #8
Figure 2. Using FindFiber mode to locate fibers –
patch panel to patch panel
Patch Panel
Patch Panel
Fiber Links
SimpliFiber Pro
meter
ID #3
ID #4
ID #5
Fiber Links
ID #3
ID #4
ID #5
Figure 1. Using FindFiber mode to locate fibers –
patch panel to wall outlet
ID #3
ID #4
ID #5
ID #6ID #7ID #8
Figure 2. Using FindFiber mode to locate fibers –
patch panel to patch panel
Patch Panel
The multimode source is a dual wavelength
850/1300 source and incorporates an 850 nm
LED and a 1300 nm LED, perfect for
multimode fiber testing. You can add an
optional singlemode 1310/1550 source to
any kit as your testing needs evolve. These
laser sources are ideal for all singlemode fiber
testing. All sources are compatible with the
SimpliFiber Pro optical power meter.
The FindFiber™ Remote ID source is a new
platform in the Fluke Networks family. When
used with the optical power meter, these
remote ID sources allow for quick and easy
cable-routing identification.
User-friendly
Although they are effective as separate tools,
the SimpliFiber Pro optical power meter and
sources are engineered to work together.
The automatic wavelength-sensing feature of
the meter identifies the source wavelength
and sets itself appropriately so you do not
have to. This simplifies multi-wavelength
tests and saves at each wavelength to pre-
vent costly measurement errors. The compact
SimpliFiber Pro optical power meter and
sources are durable and rugged. They feature
textured, impact-resistant covers and a
compact, ergonomic shape for a comfortable
and secure grip. Long battery life assures
hours of trouble-free operation.
Verify optical loss and power levels
The SimpliFiber Pro optical power meter is
calibrated for accuracy at 850 nm, 1300 nm,
1310 nm, 1490 nm, 1550 nm and 1625 nm.
The meter features the ability to save a
reference power level, allowing a direct
display of fiber loss. It has an intuitive
four-button panel, a large LCD display screen,
and a USB port to upload test results to a PC
running LinkWare™ Cable Test Management
Software. SimpliFiber Pro sources include a
dual-wavelength 850/1300 nm source and
dual-wavelength 1310/1550 nm source.
TM
The FindFiber
at 1310 nm.
Remote ID sources transmit
Conduct pre-testing with
minimal resources
The FindFiber™ remote ID sources allow you
to identify the physical location of cabling
runs to ensure polarity and the correct
location on each fiber drop (Figure 1 and
Figure 2). This time-saving feature enables a
single technician to quickly perform double-
ended testing – ideal for pre-testing a job
site before any adds, moves, or changes.
Ensure smooth, clean fiber connections
Inspect the ends of fiber-optic connectors
with Fluke Networks’ handheld FiberInspec-
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
tor™ Mini video microscope or FiberViewer™
microscopes. All options ensure your termina-
tion is smooth, clean, and ready for optical
transmission. The FT500 FiberInspector Mini
can be used in any live fiber installation and
provides 200x viewing. The FT120 FiberViewer
provides 200x magnification for inspecting
multimode fiber end-faces while the
FT140 FiberViewer offers 400x viewing for
singlemode installations. Both FiberViewer
microscopes contain a special safety filter
to minimize the risk of eye exposure to
harmful infrared rays.
FAX 781.665.0780 - TestEquipmentDepot.com
Page 3
Verify and locate faults
Diagnose and repair simple fiber link
problems with Fluke Networks’ VisiFault™
Visual Fault Locator (VFL). The laser-powered
VisiFault locates fibers, verifies continuity
and polarity, and helps find breaks in cables,
connectors, and splices. Continuous and
flashing modes make for easier identification.
Compatible with 2.5 mm and 1.25 mm
(with optional adapter) connectors for
easy connection.
Reporting made simple
Manage test results, print professional
reports, or export data into spreadsheet
formats. SimpliFiber Pro can internally store
up to 1000 test results which can then be
uploaded to your PC using the included
LinkWare™ Cable Test Management Software.
Features
• Dual-wavelengthtesting
• Testsmultimodeandsinglemodeber
FeatureDescription Benefit
Dual-wavelength
testing
CheckActive™
FindFiber™
Remote ID
Auto wavelength
USB port
Saves 1000 results
Min/max
Six calibrated
wavelengths
Simultaneously test and save records
from two wavelengths
Connect to a fiber without any setup
and show with a simple icon and an
audible tone whether that fiber is
active.
Identify the physical location of cabling
runs to ensure polarity and the correct
location on each fiber drop. Encoded
source signal 1-8.
Automatic identification of wavelength
being transmitted.
Data connectivity via USB 2.0.Download results faster –
Save and label each test conducted. Collects test results from multiple
Allows immediate access to power range
highs and lows in a testing session.
Calibrated to extend from typical
enterprise wavelengths to two new
popular wavelengths.
Cuts testing time in half by eliminating
the need to test at each wavelength
separately.
Know for sure if connectors and ports
are live. Allows quick visual and audible
identification of a live link or port on
a switch.
Allows for quick and easy cable-routing
identification and reduces confusion.
Allows double-ended testing with
only 1 technician. Ideal for pre-testing
a job site before any adds, moves, or
changes. Allows for mapping verification
and easy documentation.
Eliminates time-consuming mistakes by
automatically detecting which source
wavelength is transmitting. Allows
measurements from both wavelengths at
to be saved in one record.
no specialty cables required.
building sites in a day and requires
only one download.
Precisely identifies intermittent
power fluctuations. Eliminates
unreliable and inaccurate guesswork.
Power meter can be used for broader
applications.
• Measuresopticalpowerandlossat850nm
and 1300 nm using the 850/1300 source
and meter
• Measuresopticalpowerandlossat
1310 nm and 1550 nm using the
1310/1550 source; calibrated wavelengths
in the power meter at 1490 nm and
1625 nm also allow for readings from
other sources
• Offersquickremoteidenticationof
cabling runs with FindFiber Remote IDs
• Conductpre-testingandqualify
cabling runs
• Auto-sensessourcewavelength
• Saves1000testresults
• Singleporttestingforsimplenetwork
connection
• Ruggedlybuiltfordemandingelduse
• LinkWare™CableTestManagement
Software documents, reports, and
manages all test data
FKT1450 Complete Fiber
Verification Kit
Page 4
SimpliFiber Pro Kit Ordering Information
ModelDescription
SFPOWERMETERSimpliFiber Pro optical power meter
SFSINGLEMODESOURCESimpliFiber Pro singlemode 1310/1500 source
FTK1000Basic Fiber Verification Kit: Includes SimpliFiber
Pro optical power meter, 850/1300 multimode
source, and carrying case
FTK1300Multimode Fiber Verification Kit: Includes
SimpliFiber Pro optical power meter,
850/1300 multimode source, VisiFault VFL,
FT120 FiberViewer, FindFiber Remote ID sources,
and carrying case; ST and LC adapter
FTK1350Multimode Fiber Verification Kit with FT500
FiberInspector Mini: Includes SimpliFiber Pro
optical power meter, 850/1300 multimode source,
VisiFault VFL, FT500 FiberInspector Mini,
FindFiber Remote ID sources, and carrying case;
ST and LC adapter
FTK1450Complete Fiber Verification Kit with FT500
FiberInspector Mini: Includes SimpliFiber Pro
optical power meter, 850/1300 multimode source,
1310/1550 singlemode source, VisiFault VFL,
FT500 FiberInspector Mini, two (2) FindFiber
Remote ID sources, and carrying case; ST and LC
adapter, NFC-Kit-Box fiber optic cleaning kit
FTK2000Singlemode Fiber Verification Kit: Includes
SimpliFiber Pro optical power meter,
1310/1550 singlemode source, and carrying case
FindFiberOne (1) FindFiber Remote ID source
FindFiber-6Set of six (6) FindFiber Remote ID sources
GLD-FTKGold Support package for SimpliFiber Pro
SimpliFiber Pro Accessories Ordering Information
ModelDescription
NFK1-SMPLX-SC62.5 uM simplex reference cord set (SC/SC x 2);
special patented damage-resistant end-faces
NFK1-SMPLX-LC62.5 uM simplex reference cord set (SC/LC, LC/LC);
special patented damage-resistant end-faces
NFK1-SMPLX-ST62.5 uM simplex reference cord set (SC/ST, ST/ST);
special patented damage-resistant end-faces
NFK2-SMPLX-SC50 uM simplex reference cord set (SC/SC x 2);
special patented damage-resistant end-faces
NFK2-SMPLX-LC50 uM simplex reference cord set (SC/LC, LC/LC);
special patented damage-resistant end-faces
NFK2-SMPLX-ST50 uM simplex reference cord set (SC/ST, ST/ST);
special patented damage-resistant end-faces
NFK3-SMPLX-SCSM simplex reference cord set (SC/SC x 2);
special patented damage-resistant end-faces
NFK3-SMPLX-LCSM simplex reference cord set (SC/LC, LC/LC);
special patented damage-resistant end-faces
NFK3-SMPLX-STSM simplex reference cord set (SC/ST, ST/ST);
special patented damage-resistant end-faces
NFA-SC-SINGLESC interchangeable adapter
NFA-LC-SINGLELC interchangeable adapter
NFA-ST-SINGLEST interchangeable adapter
General Specifications
Temperature rangeOperating: -10 0C to 50 0C
Humidity range95% (10 0C to 35 0C) non-condensing;
CertificationsCE, CSA, N10140, Class 1 laser-safe
DimensionsPower meter: 6.4 in x 3.2 in x 1.5 in
WeightPower meter: 11.5 oz (325 g)
Storage: -20 0C to 50 0C
75% (35 0C to 40 0C) non-condensing;
uncontrolled <10 0C
(16.5 cm x 8.0 cm x 3.9 cm)
MM/SM sources: 5.6 in x 3.2 in x 1.6 in
(14.2 cm x 8.1 cm x 4.1 cm)
Power measurement linearity 850 nm: +/- 0.2 dB; +/- 0.2 dB for power
Resolution0.01 dB
Battery life>50 hours typical
Memory1000 loss or power measurements
Serial communication
physical interface
Optional adapters include LC, ST
1300, 1310, 1490, 1550, 1625: 10 to -60
dBm
from 0 dBm to -45 dBm, +/- 0.25 dB for
power < -45 dBm; 1300 nm, 1310 nm, 1490
nm, 1550 nm, 1625 nm: +/- 0.1 dB; +/- 0.1
dB for power from 0 dBm to -55 dBm, +/-
0.2 dB for power > 0 dBm and < -55 dBm
USB
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.