DATA SHEET > NetWave Series 1-phase > 20130304
NETWAVE SERIES (1-PHASE)
SINGLE PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES
FOR TESTS ACCORDING TO ...
> AIRBUS
> BOEING
> DO 160 Section 16
> EN 61000-3-11
> EN 61000-3-12
> EN 61000-3-2
> EN 61000-3-3
> EN 61000-4-11
> EN 61000-4-13
> EN 61000-4-14
> EN 61000-4-17
> EN 61000-4-28
> EN 61000-4-29
> IEC 61000-3-11
> IEC 61000-3-12 Ed.2:2011
> IEC 61000-3-2
> IEC 61000-3-3
> IEC 61000-4-11
> IEC 61000-4-13
> IEC 61000-4-14
> IEC 61000-4-17
> ...
NETWAVE - SIMULATION OF THE MOST REQUIRED POWER SUPPLY PHENOMENON
The NetWave series (1-phase) are single phase AC/DC power sources, specifically designed to meet the requirements as per
the standards IEC/EN 61000-4-13, -4-14 and -4-28. Used as a DC power source it covers the requirements as per the
standards IEC/EN 61000-4-17 (Ripple on DC) and IEC/EN 61000-4-29 for voltage dips and interruptions on DC supplies.
With its low distortion and high stability, even if supplying dynamic loads, the NetWave series guarantees full compliant
measurements for harmonics and flicker testing as per IEC/EN 61000-3-2,-3-3, -3-11 and -3-12 as well as JIS C 61000-3-2.
The NetWave series is well suited for testing inverters (e.g. solar power, wind power) and e-vehicles.
Additionally, the NetWave series (1-phase) offers the necessary capabilities for avionics testing as per DO-160, Airbus
ABD0100 and Boeing as well as per MIL-STD-704.
HIGHLIGHTS
> Wide Power Bandwidth; DC - 5kHz
APPLICATION AREAS
INDUSTRY
AVIONICS
> Output Power up to 7,500VA AC and 9,000W DC
> Output Voltage max. 360V AC and +/- 500V DC
MEDICAL
MILITARY
> High Inrush Current Capability up to 200A
RESIDENTIAL
RENEWABLE ENERGY
> Extended trigger and control capabilities
(NetWave 7.3)
www.emtest.com © EM TEST > PAGE 1/5
DATA SHEET > NetWave Series 1-phase > 20130304
TECHNICAL DETAILS
MODEL OVERVIEW
1-PHASE NETWAVE-MODELS
NetWave 3 Multifunctional AC/DC source,
3,500VA AC / 4,500W DC
NetWave 7 Multifunctional AC/DC source,
7,500VA AC / 9,000W DC
NetWave 7.x Multifunctional AC/DC source,
7,500VA AC / 9,000W DC,
with built-in isolation transformer
required to perform tests as per
aircraft (DO-160, Airbus and Boeing)
and military (MIL-STD-704)
standards
TECHNICAL DETAILS
NETWAVE 3
Output voltage 0V - 300V AC (RMS)
0V - +/-425V DC
Output current 12A (RMS) continuous
21A (RMS) short-term (max. 3s)
100A repetitive peak
NETWAVE 7
Output voltage 0V - 300V AC (RMS)
0V - +/-425V DC
Output current 26A (RMS) continuous
47A (RMS) short-term (max. 3s)
200A repetitive peak
NETWAVE 7.2 / NETWAVE 7.3*
Output voltage 0V - 360V AC (RMS)
0V - +/-500V DC
Output current
(@max. 300V AC)
26A (RMS) continuous
47A (RMS) short-term (max. 3s)
200A repetitive peak
* EXTENDED CAPABILITIES FOR NETWAVE 7.3
SourceAC mode PLL synchronization with other
voltage sources
Trigger channel Extended trigger functions
Segment "Step" Ramping of voltage and/or frequency
in constant time windows
Extern mode Control of the NetWave by an
external control signal
Simple Mode Optimized control for integration of
the Netwave into existing
automation environments (for
example Matlab)
www.emtest.com © EM TEST > PAGE 2/5