Atec MXCTS User Manual

California Instruments MX Compliance Test Systems
Harmonics and Flicker testing of high power AC products
Introduction
The MX45/30-CTS Series is a complete, turn­key compliance test system for EN IEC 61000­3-12 (Harmonics), EN IEC 61000-3-11 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analyzer & conditioning system (PACS-3-75) and a PC based data acquisition system, the MX45/30­CTS provides a complete turn-key solution for IEC testing. The Windows™ based MXCTS software performs all required IEC tests and generates detailed test reports. Comprehensive data les are stored on disk to allow post test analysis.
The MXCTS system implements various IEC standards including the new Amendment 14 and provides a software only upgrade path for future standard changes.
Three phase loads are connected using rear terminal blocks.
Covered EN61000 Standards
The following tests can be performed using an MX45/30 based CTS system:
EN 61000-3-12 Harmonics EN 61000-3-11 Flicker CTSH EN 61000-3-2 Harmonics (option) EN 61000-3-3 Flicker (option) EN 61000-4-11 Pre-Compliant EN 61000-4-13 Harmonics and Inter­ harmonics (requires option -413) EN 6100-4-17 DC Ripple EN 61000-4-14 Voltage Fluctuations EN 61000-4-28 Frequency Variations EN 61000-4-29 DC Dips and Interruptions (Pre-compliance) EN 61000-3-12 Harmonics
Full compliance testing for current harmonics emissions products is supported. Support for the 2001 version (Amendment 14) of the Harmonics
standard is built-in for full compliance with both harmonics standards.
EN 61000-3-11 Flicker
Flicker PST & PLT results are displayed in real-time during the entire test. No need to wait until the entire test is completed to know if the EUT passed or failed. A Ztest reference impedance (OMNI-3-75) is provided for IEC 61000-3-11 icker testing (-CTSH) and a Zref (OMNI-3-37MX) for IEC 61000-3-3 icker testing (-CTSL).
Congurations
The MX45/30-CTS system is available with icker reference impedance for either IEC61000-3-11 (-CTSH) or IEC 61000-3-3 (-CTSL). A system with both impedances and both high and low power software is available as well (-CTSHL). It is strongly recommended that California Instruments supply the required PC with the test system due to A/D card compatibility. (Option CIC-PC)
CENELEC - Amendment 14
The MX45-CTS, with its exible architecture, allows the user to select measurements to be made per the recently harmonized amendment, or older standards.
30–90 kVA
150–300 V
0–62.5 A/Phase
AMETEK Programmable Power
9250 Brown Deer Road San Diego, CA 92121-2267 USA
858.458.0223
sales@ProgrammablePower.com
10252013
219
MX Compliance Test Systems
MX45-CTS Series Model Numbers
Model Description Flicker Impedance Software
MX45-CTSH IEC 61000-3-11/12 harmonics and icker test system OMNI-3-75 CTSMXH
MX45-CTSL IEC 61000-3-2/3 harmonics and icker test system OMNI-3-37MX CTSMXL
MX45-CTSHL Combination harmonics and icker test system OMNI-3-37MX
OMNI-3-75
Current Harmonics test display
CTSMXL CTSMXH
Real-time Flicker test display
Detailed Test Reports and Data
www.ProgrammablePower.com220
Loading...