DATA SHEET > CDNs > 20120612
CDNS
COUPLING / DECOUPLING NETWORKS ACCORDING TO
IEC/EN 61000-4-6, IEC/EN 60945 AND CISPR 15/EN 55015
FOR TESTS ACCORDING TO ...
> CISPR 15
> EN 55015
> EN 60945
> EN 61000-4-6
> IEC 60945
> IEC 61000-4-6
COUPLING/DECOUPLING NETWORKS FOR CONDUCTED IMMUNITY TESTING
Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6
and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the
interconnection lines. Dedicated CDNs are also used as per CISPR 15 and EN 55015 for measurement of emission.
A large range of appropriate coupling/decoupling networks as well as the necessary accessories for standard compliant
levelling are avialable.
You'll find an overview of all available CDN's on the datasheet. Apart from the listed standard coupling/decoupling networks
EM TEST also supply special or customised coupling/decoupling networks.
HIGHLIGHTS
> M-type CDNs for supply lines available up to 75A
> S-type CDNs for shielded lines and different types
of connectors (BNC, USB, SubD etc.)
> T-type CDNs for telecom lines
> AF-type CDNs for unbalanced lines
> Calibration certificate included
APPLICATION AREAS
INDUSTRY
MEDICAL
BROADCAST
TELECOM
RESIDENTIAL
RENEWABLE ENERGY
www.emtest.com © EM TEST > PAGE 1/8
DATA SHEET > CDNs > 20120612
TECHNICAL DETAILS
QUALITY BY LÜTHI
ALL EM TEST CDNS ARE MANUFACTURED BY LÜTHI
The Lüthi AG, headquartered in Frenkendorf, Switzerland,
is one of the world's leading and best known
manufacturers of coupling/decoupling networks for
conducted immunity testing and emission measurement
as well as of EMC measuring clamps and accessories.
In January 2010 the Lüthi AG became a part of the EM TEST
Group. It will be independently operated and the Lüthi
brand will remain. As one of the pioneers in the
development of EMC measurement clamps, Lüthi AG
products are chosen by the most important suppliers of
EMC measuring systems world-wide.
www.emtest.com © EM TEST > PAGE 2/8
DATA SHEET > CDNs > 20120612
TECHNICAL DETAILS
CDNS FOR MAINS SUPPLY LINES,
TYPE M
16A M-TYPE CDN MODELS
CDN-M1/16A For Earth conductor
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 230MHz
CDN-M2N For 2 AC/DC supply lines
- AE: IEC 320 connector
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 300MHz
CDN-M2-16A S2 For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 1,000V/16A
- Frequency 150kHz - 80(230)MHz
CDN-M2 S2 For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 10kHz - 80MHz
CDN-M2/400V For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 400V/16A
- Frequency 150kHz - 80(230)MHz
CDN-M2/750V For 2 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 750V/16A
- Frequency 150kHz - 80(230)MHz
CDN-M2/M3N For 2 or 3 AC/DC supply lines
(switchable)
- AE: IEC 320 connector
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 300MHz
CDN-M3N For 3 AC/DC supply lines
- AE: IEC 320 connector
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 150kHz - 300MHz
16A M-TYPE CDN MODELS (CONTINUATION)
CDN-M3 S3 For 3 AC/DC supply lines
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 240V/16A
- Frequency 10kHz - 80MHz
CDN-M3/400V For 3 AC/DC supply lines (L,N,PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 400V/16A
- Frequency 150kHz - 80 (230) MHz
CDN-M3/Delta For 3 AC/DC supply lines (L1/L2/L3)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 80 (230) MHz
CDN-M4/PE For 4 AC/DC supply lines
(L1/L2/L3/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 230MHz
CDN-M4/N For 4 AC/DC supply lines
(L1/L2/L3/N)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 230MHz
CDN-M5/16A For 5 AC/DC supply lines
(L1/L2/L3/N/PE)
- AE: 4mm safety lab connectors
- EUT: 4mm safety lab connectors
- Voltage/current max. 3x400V/16A
- Frequency 150kHz - 230MHz
...
www.emtest.com © EM TEST > PAGE 3/8