Features & Benefits
High Capacity Storage and Playback of MPEG Transport Streams Files Let you Build, Maintain and Use a Large Local Library
Real-time Updating of Time Stamps and Time Tables for Error-free Looping
DVB, ATSC and ISDB Sample Transport Streams Provided To Get You Started
Easy Integration with MTS300 for Transport Stream Creation to Support Compliance and Stress Testing of Video Products Using MPEG-2 Technology
100Base-T Ethernet Download of Transport Streams for Optimal Flexibility
Color Hierarchical Display of Transport Stream Components for Quick and Easy Interpretation of Complex Structures
A Full Suite of Electrical Interfaces Let You Address a Wide Range of Applications
PSI/SI/PSIP Editor to Create Streams That Simulate Marginal Conditions
Dynamic Insertion of System Information for “On-the-fly” Stream Modification to Reduce Test and Troubleshooting Time
Locally Edit Transport Stream Headers to Help You Fully Exercise Designs
Extensive and Flexible Control of PCR Value and Interval Jitter Lets You Stress and Characterize Product Performance
Delete or Replace Transport Stream Packets and Sections in Real Time to test Products Under a Wide Range of Conditions
Applications
IRD/STB Design Test IRD/STB Manufacturing Test Evaluation of Professional
MPEG Equipment Performance Verification
of MPEG Systems Substitution Generator
for Digital TV Transmitters
MPEG Test and Monitoring Generator
MTG300
The MTG300 MPEG-2 Generator is a flexible, cost-effective source of MPEG-2 transport streams for design evaluation and conformance testing of compressed digital video products. This instrument offers storage and playback of MPEG-2 transport streams compliant with the ATSC,DVB and ISDB standards.The MTG300 generates error-free, seamless transport streams for long term playout.To facilitate complete stress testing, the MTG300 features the most comprehensive capabilities for customizing transport streams on the market. The basic functionality of the MTG300, combined with the customization features of the MTG300, makes this MPEG generator ideally suited for use in research, design and manufacturing applications.
Characteristics
Performance
Maximum Data Rate – 80 Mb/s. Minimum Data Rate – 0.5 Mb/s. Output Rate Resolution – 1 Hz or 10 ppm,
whichever is larger.
Clock
Internal Reference – 27 MHz ±1 ppm. Output Clock Frequency – 0.5 MHz to 80 MHz
locked to reference clock. External Reference Input – 27 MHz ±1 ppm
(recommended).
Transport Stream Interfaces
ASI – Burst and non-burst, user selectable. SSI – SMPTE 310. DHEI. ECL – Parallel and Serial. TTL – Parallel and Serial. LVDS– Parallel and Serial.
Packet Length
188, 204 or 208 bytes.
Control Interfaces
The instrument can be controlled through the Ethernet port.
MPEG Generators • www.tektronix.com/video
1
MPEG Test and Monitoring Generator
MTG300
For the most up-to-date product information
visit our web site at
www.tektronix.com
Copyright © 2002, Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,issued and pending. Information in this publi­cation supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix,Inc.All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies.
04/02 HB/XBS 20W-13530-4
Seamless Looping
Any transport stream can be looped, with real-time update of all time stamps, continuity counters and time tables (TDT or STT).
PSI, SI or PSIP Tables Manipulation
PSI/SI/PSIP tables can be dynamically deleted, inserted or replaced by user-defined tables.Tables can be created by the MTS300 Series.The starting and ending time of the table changes can be set to any value within PCR reference time.
Real-time Stress Addition
The following can be applied to any transport stream:
TS Header Stress –
The packet headers for any TS element can be modified to any value. Packets from any PID can be deleted over a user-specified interval. Time tables (TDT or STT) can be inserted,including real-time updating of the time. Undefined PIDs (i.e., not default PID numbers,or those referenced by the PAT or any PMT) can be inserted.
PCR Stress –
PCR Jitter: For a PCR value change,pattern,period, duration and amplitude can be defined. PCR Period: For a PCR packet period change,both period and period jitter are supported; pattern, period, duration and amplitude can be defined.
Transport Stream Storage
At least 18 GB standard.Any transport stream length, up to the entire storage amount, can be generated.
Sample Transport Streams
Sample streams can be seamlessly looped, including updating of all time stamps, continuity counters and time tables (TDT or STT), without buffer under- or overflow.
Transport Stream Creation
Compatible with transport stream recorders, such as the MTS300 Series, that can export a captured file in *.trp format.Also compatible with custom transport streams created by the MTS300, the MTS300 Stream Application Creation or any other software package that creates files in *.trp format.
Networking
100Base-T
MTG Comm, an included standard accessory PC software program, can download and upload transport streams through the Ethernet port to/from the MTG300.
Remote Control
MTG Comm, an included standard accessory PC software program, can control MTG300 through the Ethernet port. Stream generation start/stop, output stream selection and the recall of user presets can be controlled.
General Specifications
Environmental Characteristics
Temper ature–
Operating: +5°C to +40°C. Nonoperating: –20°C to +60°C.
Humidity –
Operating: 20% to 80% (noncondensing). Nonoperating: 5% to 90% (noncondensing).
Power Requirements
AC Line – 90 to 250 VAC, auto switching. Line Frequency – 48 to 63 Hz. Power Consumption – 200 Watts Max.
EMC
Meets intent of Directive 89/336/EEC.
Safety Certification
Complies with the following safety standards: UL3111-1 – Standard for electrical measuring
and test equipment. Can/CSA c22.2 No.1010.1 – Safety requirements
for electrical equipment for measurement, control and laboratory use.
IEC61010-1 – Safety requirements for electrical equipment for measurement, control and laboratory use.
Warranty – 1 year.
Physical Characteristics
Dimensions mm in.
Height 132 5.2 Width 430 16.9 Depth 560 22.0
Weight kg lbs.
Net 14.5 32.0
Ordering Information
MTG300
MPEG-2 Generator. Includes: User manual,Application software disk,
3.5 in., Interface cable, D-sub 25-pin, twisted pair.
Opt. D1 – Calibration data report. Opt. 1H – High capacity 36 GB HDD. Opt. 1R – Rackmount kit.
Support Options
Opt. C3 – Three years of Calibration Services. Opt. D3 – Test data (requires Opt.C3). Opt. R3 – Repair warranty extended to cover
three years.
MPEG Generators
www.tektronix.com/video
2
Contact Tektronix:
ASEAN Countries & Pakistan (65) 6356 3900
Australia & New Zealand (65) 6356 3900
Austria +43 2236 8092 262
Belgium +32 (2) 715 89 70
Brazil & South America 55 (11) 3741-8360
Canada 1 (800) 661-5625
Central Europe & Greece +43 2236 8092 301
Denmark +45 44 850 700
Finland +358 (9) 4783 400
France & North Africa +33 (0) 1 69 86 80 34
Germany +49 (221) 94 77 400
Hong Kong (852) 2585-6688
India (91) 80-2275577 Italy +39 (02) 25086 1
Japan (Sony/Tektronix Corporation) 81 (3) 3448-3111
Mexico, Central America & Caribbean 52 (55) 56666-333
The Netherlands +31 (0) 23 569 5555
Norway +47 22 07 07 00
People’s Republic of China 86 (10) 6235 1230
Poland +48 (0) 22 521 53 40
Republic of Korea 82 (2) 528-5299
Russia, CIS & The Baltics +358 (9) 4783 400
South Africa +27 11 254 8360
Spain +34 (91) 372 6055
Sweden +46 8 477 6503/4
Taiwan886 (2) 2722-9622
United Kingdom & Eire +44 (0) 1344 392400
USA 1 (800) 426-2200
For other areas contact Tektronix, Inc. at: 1 (503) 627-7111
Updated 8 February 2002
Loading...