MT9083A ACCESS MASTER OVERVIEW & SPECIFICATIONS
780/1310/1383/1490/1550/1625/1650nm (single mode), 850/1300nm (multimode)
How-To Video
All-in-One Solution for Optical Fiber Construction and Maintenance of Access, FTTx, LAN and Metro Networks
MT9083A ACCESS MASTER OVERVIEW
Optical fibers are a key technology in today’s modern communications systems, including access networks such as FTTx, CATV, and optical LANs. Moreover, optical-fiber technologies are playing increasingly important roles in mobile communications and digital broadcasting systems. Technicians maintaining these diverse systems are forced to carry a large variety of test equipment on-site, including OTDRs, Light Sources, Optical Power Meters, Visible Light Sources, etc., as well as a notebook computer for evaluating the FTTx QoS. On the other hand, fiber construction requires measuring instruments with different functions and performance. As an example, FTTx access networks use single mode (SM) fiber whereas optical LANs use multimode (MM) fiber. In addition, core and backbone networks utilize long fibers while optical access networks use short fibers, both requiring different types of measuring instruments with different performance. But now Anritsu’s new line of MT9083A ACCESS Master OTDRs solves all these problems by providing all the measurement functions and performance required for optical fiber construction and maintenance in a compact, lightweight, all-in-one unit that eliminates the burden of carrying many different test sets and instruments on-site. Whatever your work, construction or maintenance, long haul or intra-building, Anritsu has an MT9083A model for your needs.
Key Features
Ready to test in less than 15 seconds…and all day without recharging
Specialized testing modes simplify operation
High resolution and
Intelligent analysis software identifies problem splices, connectors and even macrobends
Rugged, sealed design provides years of service in the most challenging environments
IP testing option verifies throughput, frame loss and point-to-point connectivity
Test up to four wavelengths with a single unit – single mode, multimode or both
Unique in-service testing without the need for external filters
high dynamic range ensure thorough and complete fiber evaluation
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4
©2006 Anritsu. All Rights Reserved. Page 1 of 14
Designed with the Features that Matter Most
When buying products, you tend to choose ones that are innovative and from established companies. When you need to install
and maintain optical networks, this should also apply. With over 50 years of combined OTDR design, Anritsu, which now
includes NetTest, delivers the features that matter.
Having been in the test and measurement business for a long time, we understand that things like performance, portability, reliability, easy operation and of course price are important.
Quick Startup
The MT9083A is ready for measurement just 15 seconds after
power-on so productive work can start immediately.
Long Battery Life
Since AC power is not always available where you need it,
especially at fiber pedestals, the MT9083A typically provides up to 8
hours of operation on a single charge. This coupled with an optional
car cord (for cigarette lighter operation) guarantees the MT9083A is
ready when you are.
Portable
With its light weight design and user friendly dimensions, the
MT9083A is perfect for the outside plant environment and can easily
be managed with one hand. The shoulder strap (part of the
protector option) further increases portability when traveling from the
truck to the testing site.
Rugged
The MT9083A features a solid casework with no fans or vents to
allow dust or moisture from entering the unit. In addition, the
protector option (MT9083A-010) includes rubber bumpers and a
display cover for additional protection from those minor mishaps.
Generous Data Storage
With the ability to store up to 1,000 traces in internal memory and up
to 30,000 via a USB device, the MT9083A offers plenty of storage
for collecting and managing data.
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 2 of 14
No Experience Required
With the MT9083A, the experience is built in. With specialized testing
modes, automatic parameter selection, PASS/FAIL indicators as well
as features to virtually eliminate the chance to get “bad” results, the
MT9083A can make anyone seems like a 20 year veteran. It’s not
called the ACCESS Master for nothing!
Easy “drag and drop” File Transfers
When the MT9083A is connected to a PC via a USB cable, the
internal memory of the ACCESS Master can be directly accessed.
Data can be selected, dragged and dropped into the PC memory,
greatly simplifying file transfers. The MT9083A also supports use of
USB memory sticks.
Common OTDR Data Format
The MT9083A supports the universal Telcordia SR-4731 (issue 2)
format making it compatible with not only legacy Anritsu and NetTest
products, but with many other vendors data.
Free and Simple Software Upgrades
Firmware upgrades are easily performed via USB and available from
the Anritsu website for registered users or through Anritsu customer
support.
With its versatile built-in functions, the MT9083A offers the ideal solution for efficient optical fiber construction and maintenance.
All-in-one Test Set
The MT9083A delivers full featured OTDR performance plus loss test set and quality of service measurement in a surprisingly
small and lightweight package. At only 28.4cm wide x 20cm tall x 7.7cm deep and 2.2 kg (4.8 lbs.), it is field portable, yet
rugged enough to withstand the outside plant environment. When equipped with power meter, visual light source and IP test
options, it replaces several, larger pieces of test equipment.
Numeric keypad with
dedicated keys for
easy operation
Rotary dial for precise cursor
movement
Arrow keys for quick
zooming and
navigation through
menus
6.4 inch color, TFT­LCD display with
simple menus
Visible laser source for easy fiber identification
and bend/break
location
* Shown with protector option (MT9083A-010)
Up to four wavelengths
from a single port for
any application
Dual USB ports for quick
and easy data transfer
START key for simple
one-button testing
Dedicated function keys for
selecting parameters
* Shown with protector option (MT9083A-010)
Up to 8 hour battery
life plus quick
recharge
Optical Power meter
options with up to +30 dBm
measurement range
IP options for verifying QoS of 10/100/1000MB
links
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 3 of 14
Exceptional OTDR Performance…from the World’s First OTDR Manufacturer
Evaluation of access networks ranging from a few kilometers to metro networks reaching up to 100 km in length is becoming
commonplace, requiring OTDRs to have the performance and functions for evaluating both short and long fibers. Designed
with this in mind, the ACCESS Master delivers on both fronts.
Improved Short Fiber Analysis
An event dead zone of less than 1m (80 cm typical) and a
sampling resolution of 5 centimeters allow the MT9083A
to evaluate connections and troubleshoot central office,
FTTx and intra-building faults with ease – providing a
level of detail never before seen.
Fig. 1: With its high resolution optics, the MT9083A provides exceptional detail allowing users to quickly determine where the problem is – even when events are closely spaced.
Convenient Features
Extended Range Testing of 100+km Fibers
In addition to its superb high-resolution performance, the
MT9083A also features up to 38.5dB of dynamic range
allowing it to easily test 100+ km spans making it a very
useful tool for any network type.
Fig 2: Spans of over 100 km are also easily tested making the MT9083A the only tool you will need - for any network type.
Active Fiber Check
Not only can OTDR measurements be effected when the
optical fiber is in-service but there is a potential risk of
damage to the transmitter and OTDR receiver. To prevent
these problems, the MT9083A verifies if light is present
before starting measurement and will not transmit if it is.
An on-screen warning and internal OTDR protection are
also part of this useful feature.
Waveform Comparison Function
Compare current and stored trace data to easily assess
changes over time and to locate problems before they effect
service or compare traces at different wavelengths to
identify installation issues such as macrobending.
Integrated Macrobend Detection
With many technicians making the switch from copper
installations to optical fiber, installation issues such as
macrobends are bound to occur. To help prevent this,
Anritsu has developed a macrobend detection feature for the
MT9083A that will alert technicians when a possible
macrobend is present. This provides a higher quality of
service for the customer and eliminates costly
troubleshooting for you.
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 4 of 14
Event Table with User Defined Thresholds
PASS/FAIL thresholds for key acceptance criteria such as
splice loss, connector loss and reflectance can be set in the
MT9083A allowing technicians to easily assess a fiber’s
condition. Failing values are clearly highlighted in the
event table alerting technicians of potential problems.
Multiple Wavelengths and Models
With nine available wavelengths spanning both single
mode and multimode, the ACCESS Master MT9083A is
sure to meet your individual needs. Up to four of these
wavelengths can be combined into a single optical output
providing full spectrum characterization.
Wavelengths for Today’s Networks
Sometimes you just need more than the traditional 1310
and 1550 nm wavelengths to certify your next generation
networks. The MT9083A offers a host of specialized
wavelengths including1383 nm for water peak verification
of CWDM carrying fibers, 1650 nm (with integrated filter)
for live fiber troubleshooting, 1490 nm for verification of
voice, data and IP based video services and 780 nm for in-
service troubleshooting of FTTx networks - without the
need for any additional filters.
Solutions for Various Measurement Needs
Products that offer many features are often complicated to use. The MT9083A however, simplifies operation by offering task-
specific testing modes that automate testing and guide novice users. Dedicated testing modes are available for fault location,
cable installation, loss budget testing, visual fault location and IP testing.
Simple Operation
To simplify testing, the MT9083A features dedicated
measurement modes via the top menu to automate and
simplify the task at hand.
Fig.3: Dedicated measurement modes simplify testing for any skill level
Fault Location
FAULT LOCATE mode is designed for the novice or
someone who only uses an OTDR occasionally. Simply
connect the fiber and press START. The unit will verify the
fiber is connected correctly, select testing parameters and
provide a text response indicating fault/break location - easy
to read results for any skill level.
General OTDR Testing
For those who have more experience or would like to
perform more advanced testing, STANDARD OTDR mode
allows the user to set all parameters and compare traces
manually, automatically or somewhere in between.
Optical Fiber Construction and Certification
When final cable acceptance is the task at hand,
CONSTRUCTION mode greatly simplifies operation
through its innovative wizard. Select the required testing
wavelengths, number of fibers and file naming scheme and
construction mode acts as the project manager guiding the
user through the testing, while ensuring consistency with
testing parameters and filenames – virtually eliminating user
induced errors and missing files.
Value
Whatever your construction or maintenance needs, the new
ACCESS Master MT9083A is designed to reduce the time
to install, commission and maintain your optical networks –
without breaking your budget.
NETWORKS PC Software for Analysis and Reporting
Once the data is collected, NetWorks PC emulation software
makes analysis and report generation a breeze. Professional
reports including splice loss, fiber acceptance and exceptions
as well as various printing options are possible with only a
few mouse clicks.
Fig.4: Comprehensive, professional reports are easily generated
Fig.5: Various printing options ensure you have the results you need.
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 5 of 14
A True all-in-one Tester
An OTDR, Optical Power Meter, Visible Light Source, and IP tester are built into Anritsu’s compact, light-weight MT9083A
supporting tasks ranging from searching for faults in optical fibers to QoS evaluation to FTTx troubleshooting with just one
unit.
Complete Loss Test Set Features
Standard Stabilized Light Source
The OTDR port also functions as a stabilized light source
providing continuous wave, 270Hz, 1kHz and 2kHz
modulations for easy fiber identification. This is standard
equipment on all models – a chargeable option on most
other OTDRs.
Standard Integrated Power Meter
In the base unit, the OTDR port also functions as an
integrated power meter for verification of optical power
levels. Additional power meter options are available for
higher power transmissions and loop-back testing.
Visual Laser Source for easy fault location and fiber identification
A Visible Light Source is useful for tracking down bad
connections, splices and fiber management issues such as
macrobends. The optional Visible Light Source is factory
installed in the MT9083A and features up to 5 km (3 miles)
of operation.
Optical Power Meter Options - up to +30 dBm
In place of the standard power meter, the MT9083A offers
three optional optical power meters; one supports both SM
and MM fibers (MT9083A-003) while the others feature
higher measurement range for SM only applications (-004, -
005). When measurement of high optical powers, typically
more than +20 dBm (like those used by CATV companies) is
required, power meter (Option 005) using an optical
integrator sphere can be used to make long-term
measurements with high stability at levels above +30 dBm.
Data Table for Saved Results
Loss test set measurements for multiple wavelengths can be
saved into a results table for easy comparison and archiving.
The table can also be saved as a text file and exported to a
PC spreadsheet program for further manipulation or
integration into a standard company template.
Optical Access Network QoS Evaluation Using IP Test
Faults that cause drops in FTTx service speed are handled differently according to whether the cause is outside or inside the
building. In addition, business users are starting to think about guaranteed bandwidth services and higher-speed gigabit
services. The MT9083A has a built-in IP Network Connection Check function that can be used for both optical fibers and
optical access QoS evaluation.
Connection and Ping Tests
The first step in testing a service is to verify continuity. The built-in IP
Connection Test Function supports both PPPOE and DHCP services.
FTTx Download Speed Evaluation
FTTx service performance is easily evaluated from the download
throughput. Previous evaluation systems were always limited by the PC
performance (CPU speed, memory size, OS, load) and never provided
accurate measurements. Using the MT9083A Download Throughput
Measurement function frees the results from the impact of PC
performance and provides accurate results. This allows the causes of
drops in FTTx service speeds to be pinpointed to the network side or
the user’s PC side.
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 6 of 14
Throughput Measurement and Frame Counter
The MT9083A has a two-way throughput measurement function for
efficient evaluation of guaranteed bandwidth services. When an
MT9083A is connected to each end of the service, both the upload and
download speeds can be evaluated. And since the built-in frame
counter functions can be used to measure received frame types and to
count error frames, network usage efficiency can be measured easily
too.
Gigabit Ethernet Support
The MT9083A has an optional built-in 1000Base-T electrical interface
for evaluating Gigabit Ethernet throughput (up to full line rate) for
verifying performance on increasing common Gigabit Ethernet services.
Faults Identified
When issues are present, possible causes are displayed on-screen to
help isolate the source of the problem.
MT9083A ACCESS MASTER SPECIFICATIONS
Item
Without protector (option 010)
Dimensions and mass
With protector (option 010)
Display 6.5 inch TFT-LCD (640×480, with backlight, transparent type) Interface USB 1.1, TypeA×1memory, Type B×1USB mass storage).
Data Storage
Power supply
Battery
Power saving functions
Vertical scale 0.05, 0.125, 0.25, 0.5, 1.25, 2.5, 5, 6.5 dB/div IOR setting 1.000000 - 1.999999 (0.000001steps) Units km, m, kft, ft, mi Languages user selectable (English, Simplified Chinese - contact Anritsu for availability of others)
Sampling Points*2 Sampling Resolution 5 cm (min) Reflectance Accuracy Single mode: +2 dB, multimode: +4 dB Distance accuracy + 1m + 3 x measurement distance x 10
Distance Range
Testing Modes
Internal memory: 20 MB (~1000 traces) External memory (USB): ~30,000 traces with 512 MB
12 VDC, Allowable input voltage range: 10.8 – 15 VDC 100 to 240 VAC, Allowable input voltage range: 90 to 264 V, 50/60 Hz
Type: Lithium ion Operating Time*1: 8 hours Recharge Time: <5 hrs (power off)
Backlight off: disable/1–99 minutes Auto shutdown: disable/1–99 minutes
Normal: 5001, High density: 20001 or 25001
Single mode: 0.5, 1, 2.5, 5, 10, 25, 50, 100, 200 km (except 780nm: 0.5, 1, 2.5km) Multimode: 0.5, 1, 2.5, 5, 10, 25, 50, 100 km
Fault locate: provides end/break location, end to end loss, fiber length Standard OTDR: user selectable automatic or manual set-up Construction OTDR: automated, multi-wavelength testing Light source: stabilized light source (CW, 270Hz, 1kHz, 2kHz output) Loss test set (optional): power meter and light source Visual fault locator (optional): visible red light for fiber identification and troubleshooting IP test (optional): connectivity and throughput for 10/100/1000 MB
General Specifications
Size: 270(W) x 165(H) x 61(D) mm Weight: 2.2 kg (4.8 lbs) including battery Size: 284(W) x 200(H) x 77(D) mm Weight: 2.9 kg (6.4 lbs) including battery
-5
+ marker resolution (excluding IOR uncertainty)
Auto or manual operation, displayed in table format User defined PASS/FAIL thresholds:
Fiber event analysis
OTDR trace format Telcordia universal issue 2 (SR-4731)
Other functions
Environmental conditions
EMC EN61326:1997/A1:1998/A2 : 2003 (Class A, Annex A)
Laser Safety
Notes
1
Typical, backlight off, sweeping halted at 25oC, 6 hours typical continuous testing
2
Either high density value is selected depending on distance range
3
Sampling mode normal. Except models 062, 068 – 1 second or less
- reflective and non-reflective events: 0.01 to 9.99 dB (0.01 dB steps)
- reflectance: 20.0 to 60.0 dB (0.1 dB steps)
- fiber end/break: 1 to 99 dB (1 dB steps) Number of detected events: up to 99 Macrobend detection
Real time sweep*3: 0.15 second Loss modes: 2 point loss, dB/km, 2 point LSA, splice loss, ORL Averaging modes: timed (5 – 180 seconds) Live Fiber detect : verifies presence of communication light in optical fiber( >-40dBm) Connection check: Automatic check of OTDR to FUT connection quality Trace overlay and comparison
Operating temperature and humidity: 0 to +40C,<80%non-condensing) Storage temperature and humidity: -20 to +60C, <80% non-condensing) Vibration: Conforming to MIL-T-28800E Class 3
Drop: MIL-T-28800E Style C (20.3 cm corner, surface total 14 times shocks, Power OFF) Dust proof: MIL-T-28800E Class 2
IEC Pub 60825-1:2001 Class:1 model 051, 052, 060, 061, 062 Class:1M model 050 21CFR1040.10 (laser notice no. 50)
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 7 of 14
OTDR Specifications
Model
Wavelength*4
Fiber Type
Pulsewidth*8 Dynamic Range *5
Deadzone (Fresnel) *6
Deadzone (Backscatter) *7
050 1310+30nm 38.5dB <5m
051 1550+30nm 37dB <5.5m
052 1650+5nm 33.5dB <6.5m
053 1310/1550+30nm 38/36.5dB <5/5.5m
054 1550+30/1650+5nm 36/33.5dB <5.5/6.5m
055
056
057
058
059
1310/1550+ 1650+
1310/1490/1550
30nm
+
1310/1550/1625
30nm
+
1310/1490/1550/ 1625+
1310/1550/1625+ m, 1383+
5nm
30nm
2nm
30nm,
30n
Single Mode (SMF)
8-10/125um ITU-T G.652
3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000, 10000, 20000ns
37.5/36/33.5dB <
1m
36/34.5/34.5dB <
<
(80 cm typical)
36/34.5/31.5dB <
34/32.5/32.5/
29.5dB
34/32.5/29.5/
33dB
5/5.5/6m
6/6.5/6.5m
6/6.5/7.5m
7/7.5/7.5/8.5m
<
7/7.5/8.5/7.5m
<
060 1490+30nm 36.5dB <5.5m
061 1625+30nm
062 780+20nm 8dB (10ns) 1m <7m
780nm: 5, 10ns
068 780+20/1550+30nm
33.5dB
8/36.5dB 1m <
<
6.5m
7/5.5m
063
1310/1550+
850/1300+
30nm,
30nm
064 850/1300+30nm 28/27dB <4/5m (3/4m typ)
065 850+30nm
Notes
*4
25°C, Pulse width: 1 µs (all except 850, 1300, 780 nm) , 850/1300 nm: 100ns, 780 nm: 10ns
*5
Pulse width: 20 µs (Options 050 to 061, Option 063 1310/1550 nm, Options 068 1550 nm)
HYBRID
(SMF/MMF)
Multimode (MMF)
62.5/125um
Same as
SMF & MMF
3, 10, 20, 50, 100, 200, 500, 1000, 2000, 4000ns
38/36.5dB,
28/27dB
28dB
1m
<
(80 cm typical)
5/5.5m,
<
<
4/5m (3/4m typ)
4m (3m typ)
<
Pulse width: 4 µs (Options 063, 064 1300 nm), Pulse width: 100 ns (Options 063, 065 850 nm)
Pulse width: 10 ns (Options 062, 068 780 nm)
Distance range: 100 km (Options 050 to 061, Option 063 1310/1550 nm, Options 068 1550 nm)
Distance range: 25 km (Option 063 850/1300 nm, Options 064, 065 850/1300 nm)
Distance range: 2.5 km (Option 062, 068 780 µm)
….Averaging: 180 seconds, SNR=1 method, 25°C
*6
Pulse width: 3 ns (Options 050 to 061, 063, 064, 065, Options 068 1550 nm)
Pulse width: 5 ns (Options 062, 068, 780 nm)
Return loss: 40 dB, 25 (Refer to the figure below)
*6
*7
Pulse width 10 ns, return loss 55 dB, Deviation ±0.5 dB, 25°C
*8
1000-4000 ns cannot be selected when wavelength is 850 nm
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 8 of 14
Loss Test Set Specifications – Standard on all models
Stabilized Light Source
(through OTDR port)
Standard Integrated Power Meter
*10
(through OTDR port)
*13
Item Specification Item Specification
Wavelength Same as OTDR Maximum Input +10 dBm
<
Spectral Width*9
10nm (1383: <1nm) Measurement Range -50 to -5 dBm
Fiber Type Same as OTDR Fiber Type Same as OTDR
Optical Connector Same as OTDR Optical Connector Same as OTDR
Output Power*9
Output Stability
*11
Modes of Operation
*12
–5 ±1.5 dBm
+
0.1dB
CW, 270Hz, 1kHz, 2kHz
Laser Safety Same as OTDR
Accuracy
Supported Wavelengths 1310, 1550, 1625 nm plus
*16
+6.5%
* 1490 nm (056, 058, 060)
* 1383 nm (059)
* 1650 nm (050, 051, 053, 054, 055, 057, 061)
Loss Test Set Specifications – Optional on all Models*13
Power meters (003, 004, and 005) and visual light source must be added as separate line items.
Optical Power Meter (Option 003, 004, 005)
Option Number MT9083A-003 MT9083A-004 MT9083A-005
Supported Fiber Type Single Mode: 8-10/125
um (G.652), Multimode:
62.5/125um
Measurement Range
*14
+3 to -70 dBm +23 to -50 dBm +30 to -43 dBm
Single Mode: 8-10/125 um (G.652)
*PC only for UPC connector, angled
only for APC connector*
Wavelength Range 750 to 1700 nm 1200 to 1700 nm
Calibrated Wavelengths 850, 1300, 1310, 1383,
1310, 1383, 1490, 1550, 1625, 1650 nm
1490, 1550, 1625, 1650
nm
Optical Connector Universal – uses
MA9005A adapters
Accuracy
*15
+5%
Universal – uses UNIV-XX adapters
(same as OTDR)
Linearity +3%
Features Store reference, loss table, recognition of modulated light (270Hz, 1kHz, 2kHz)
Visible Light Source (Option 002)
Central wavelength 650 nm ±15 nm (at 25oC)
Optical output
-2 ± 1.5 dBm CW
Output optical fiber 8-10/125 µm, SMF (ITU-T G.652)
Optical connector 2.5mm universal
Optical safety IEC Pub 60825-1Class 3R, 21CFR1040.10
Environmental Same as OTDR
Notes
*9
CW, 25oC, SMF or MMF
*10
Light source not available at 780 nm, power meter not available at 780, 850, 1300 or 1650 nm
*11
CW, 0° to 40 (±1) difference between max/min. values over 1 minute, SM fiber
*12
Modulation +1.5% with 10 minute warm up
*13
If option 003, 004 or 005 is ordered, the standard integrated power meter is not available
*14
Peak power, subtract 3 dB for modulated tones
*15
CW, model 003: @-10 dBm 1310 and 1550 nm, model 004/005: @0 dBm
*16
CW input, -20 dBm @ 1550 nm, 23oC
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 9 of 14
*13
Single Mode: 8-10/125 um
(G.652)
Universal – uses MA9005B
adapters
MT9083A ACCESS MASTER Selection and Ordering Guide
1) Select Model
Includes ACCESS Master OTDR, AC charger/adapter, battery pack (1) and printed user’s manual. Also included are choice of one OTDR connector adapter (two for model 063) and line cord – select these below.
Model/
Order No.
MT9083-050 1310nm, single mode General-purpose model for construction, maintenance and fault location
MT9083-051 1550nm, single mode General-purpose model for construction, maintenance and fault location
MT9083-052 1650nm, single mode In-service measurement – integrated filter to block transmissions
MT9083-053 1310/1550nm, single mode General-purpose model for construction, maintenance and fault location
MT9083-054 1550nm & 1650nm, SM
MT9083-055 1310/1550nm & 1650nm, SM
MT9083-056 1310/1490/1550nm, SM General-purpose plus 1490 nm for FTTx/PON applications
MT9083-057 1310/1550/1625nm, SM General-purpose plus enhanced macrobend detection at 1625 nm
MT9083-058 1310/1490/1550/1625nm, SM General purpose for any application or full spectrum characterization
MT9083-059 1310/1383/1550/1625nm, SM General-purpose plus supports Water Peak testing at 1383 nm
MT9083-060
MT9083-061
MT9083-062
Wavelength Application
General-purpose models for construction, maintenance and fault location plus In-
service measurement – integrated filter to block transmissions
1490nm, single mode FTTx/PON testing
1625nm, single mode Enhanced macrobend detection
780nm, single mode For troubleshooting live FTTx/PON networks
MT9083-068 780 &1550nm, single mode For troubleshooting live FTTx/PON networks plus verification and macrobend
detection on dark fibers
MT9083-063 850/1300 nm (multimode)
1310/1550 nm (single mode)
MT9083-064 850/1300 nm, multimode Multimode fiber model
MT9083-065 850 nm, multimode Multimode fiber model
Best unit for contractors or anyone who installs or maintains hybrid networks
2) Select Line Cord
Line Cord
One line cord included at no charge - must be added as a separate line item
Model/Order Description Model/Order No. Description
MT9083A-US United States line cord MT9083A-AU Australia line cord
MT9083A-UK United Kingdom line cord MT9083A-IT Italy line cord
MT9083A-EU European Union line cord
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 10 of 14
3) Select OTDR Connector Type
Optical Connector
One adapter included at no charge (two with models 054, 055, 063) - must be added as a separate line item.
Model/Order No. Description Model/Order No. Description
MT9083A-025 FC-APC connector - single mode only
(additional charge applies)
MT9083A-026 SC-APC connector - single mode only
(additional charge applies)
MT9083A-033 LC connector MT9083A-040 SC connector
MT9083A-037 FC connector MT9083A-043 HMS-10/A connector
MT9083A-038 ST connector
MT9083A-039 DIN connector
4) Select Loss Test Set Options
Optical Power Meter
Must be added as separate, chargeable line items.
Model/Order No. Description
MT9083A-003 SMF/GIF Optical Power Meter
MT9083A-004 SMF Optical Power Meter
MT9083A-005 SMF High Power Optical Power Meter
Visible Light Source
Model/Order No. Description
MT9083A-002 Visible Laser Diode
4a) Select Power Meter Connector Type (option -003 or -005 only)
One adapter included at no charge, select from replacement adapter section. Must be added as a separate line item.
5) Select Network Test Options
Network test function
Must be added as separate, chargeable line items.
Model/Order No. Description
MT9083A-001 IP Network Connection Check Function
MT9083A-011 Gigabit Ethernet Upgrade (requires option MT9083A-001)
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 11 of 14
)
6) Select Accessories & Replacement Items
Accessories
Must be added as separate, chargeable line items.
Model/Order No. Description
MT9083A-010 Protector (includes rubber bumpers, display cover and shoulder strap)
MT9083A-MAN Hardcopy MT9083A operation manual
MT9083A-IPMAN IP network connection check function manual
B0582A Soft carrying case
B0583A Hard carry case for MT9083A - attaché style
B0549 Hard carry case for MT9083A with handle and wheels
Z0921A Replacement battery pack for MT9083A
J1295 Car plug cord
NETWORKS PC emulation software for data analysis and reporting
Peripherals
BL-80R2 Thermal printer kit (must also order BL-100W AC adapter, J1314 printer cable and BL-80-30 paper rolls)
BL-100W AC adapter for BL-80R2 printer
J1314 Printer cable for BL-80R2 printer
BL-80-30 Printer paper for BL-80R2 Thermal Printer (10 rolls/set)
Retrofit Options for existing units – unit must be returned to authorized service center
MT9083A-110 Protector (retrofit)
MT9083A-103 SMF/GIF Optical Power Meter (Retrofit)
MT9083A-104 SMF Optical Power Meter (Retrofit)
MT9083A-105 SMF High Power Optical Power Meter (Retrofit)
MT9083A-102 Visible LD (Retrofit)
MT9083A-101 IP Network Connection Check Function (retrofit)
MT9083A-111 Gigabit Ethernet Upgrade (retrofit - requires option MT9083A-001 or MT9083A-101)
Replacement Adapters
Type
LC UNIV-LC MA9005A-33 MA9005B-33
FC UNIV-FC MA9005A-37 MA9005B-37
Angled FC (AFC) UNIV-AFC N/A N/A
ST UNIV-ST MA9005A-38 MA9005B-38
DIN UNIV-DIN MA9005A-39 MA9005B-39
HMS-10A J0618F MA9005A-43 MA9005B-43
SC UNIV-SC MA9005A-40 MA9005B-40
OTDR/source port/
Power meter (MT9083A-004
Power meter
(MT9083A-003
Power meter
(MT9083A-005
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 12 of 14
Related Anritsu Products
CMA50 Optical Loss Test Set
All-in-one light source, power meter, visual fault locator and optical return loss meter for optical fiber construction and maintenance. They are offered with common calibration wavelength and connector options to meet any testing requirement from FTTx networks to long haul telephony links to multimode LAN, and CATV.
CMA5 Optical Power Meter and Light Source
The CMA5 Series Power Meters are ideal for attenuation and power throughput measurements on point-to-point fiber optic links. The CMA5 Series Light Sources provide an economical and stable laser source for use in point-to-point attenuation measurement. They feature a rugged design, built to withstand the difficult testing environment of fiber optic cable installation and maintenance.
CMA 5000 Multilayer Testing Platform
The CMA5000 is the industry's premier test and measurement solution featuring Gigabit Ethernet, DWDM, SONET/SDH, OTDR, ORL, PMD and CD applications. Through its open-architecture design, the CMA5000 offers the highest performance measurement applications in one powerful, modular platform.
CMA3000 Mobile and Fixed Access Network Tester
CMA 3000 is designed specifically for field technicians who install and maintain mobile-access and fixed-access networks. The CMA 3000 is a powerful tool for a wide range of applications, including fast first-aid troubleshooting to comprehensive, in-depth and all-layer analysis of transmission problems. The basic CMA 3000 configuration, with its two 2 Mbps receivers and transmitters, supports framed and unframed testing and monitoring of 2 Mbps systems.
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 13 of 14
Anritsu Corporation
5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan
Phone: +81-46-223-1111
Fax: +81-46-296-1264
U.S.A.
Anritsu Company
1155 East Collins Blvd., Richardson, TX 75081, U.S.A.
Toll Free: 1-800-ANRITSU (267-4878)
Phone: +1-972-644-1777
Fax: +1-972-671-1877
Canada
Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata,
Ontario K2V 1C3, Canada
Phone: +1-613-591-2003
Fax: +1-613-591-1006
Brazil
Anritsu Electrônica Ltda.
Praca Amadeu Amaral, 27 - 1 Andar
01327-010-Paraiso-São Paulo-Brazil
Phone: +55-11-3283-2511
Fax: +55-11-3288-6940
U.K.
Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K.
Phone: +44-1582-433280
Fax: +44-1582-731303
France
Anritsu S.A.
9, Avenue du Québec Z.A. de Courtabœuf
91951 Les Ulis Cedex, France
Phone: +33-1-60-92-15-50
Fax: +33-1-64-46-10-65
Italy
Anritsu S.p.A.
Via Elio Vittorini, 129, 00144 Roma, Italy
Phone: +39-6-509-9711
Fax: +39-6-502-2425
Sweden
Anritsu AB
Borgafjordsgatan 13, 164 40 KISTA, Sweden
Phone: +46-853470700
Fax: +46-853470730
Finland
Anritsu AB
Teknobulevardi 3-5, FI-01530 Vantaa, Finland
Phone: +358-20-741-8100
Fax: +358-20-741-8111
Denmark
Anritsu A/S
Kirkebjerg Allé 90 DK-2605 Brøndby, Denmark
Phone: +45-72112200
Fax: +45-72112210
United Arab Emirates
Anritsu EMEA Ltd.
Dubai Liaison Office
P O Box 500413 - Dubai Internet City
Al Thuraya Building, Tower 1, Suit 701, 7th Floor
Dubai, United Arab Emirates
Phone: +971-4-3670352
Fax: +971-4-3688460
Singapore
Anritsu Pte Ltd.
10, Hoe Chiang Road, #07-01/02, Keppel Towers,
Singapore 089315
Phone: +65-6282-2400
Fax: +65-6282-2533
Germany
Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1
81829 München, Germany
Phone: +49 89 442308-0
Fax: +49 89 442308-55
P.R. China (Hong Kong)
Anritsu Company Ltd.
Suite 923, 9/F., Chinachem Golden Plaza, 77 Mody Road,
Tsimshatsui East, Kowloon, Hong Kong, P.R. China
Phone: +852-2301-4980
Fax: +852-2301-3545
P.R. China (Beijing)
Anritsu Company Ltd.
Beijing Representative Office
Room 1515, Beijing Fortune Building,
No. 5, Dong-San-Huan Bei Road,
Chao-Yang District, Beijing 10004, P.R. China
Phone: +86-10-6590-9230
Fax: +86-10-6590-9235
Korea
Anritsu Corporation, Ltd.
8F Hyunjuk Building, 832-41, Yeoksam dong,
Kangnam-ku, Seoul, 135-080, Korea
Phone: +82-2-553-6603
Fax: +82-2-553-6604
Australia
Anritsu Pty Ltd.
Unit 21 / 270 Ferntree Gully Road,
Notting Hill, Victoria 3168 Australia
Phone: +61-3-9558-8177
Fax: +61-3-9558-8255
Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816
Fax: +886-2-8751-1817
India
Anritsu Corporation
India Liaison Office
Unit No. S-3, Second Floor, Esteem Red Cross Bhavan,
No. 26, Race Course Road, Bangalore 560 001, India
Phone: +91-80-32944707
Fax: +91-80-22356648
ISO 9000:2001 certified. IMT9083A-SPEC01-0609-A4 ©2006 Anritsu. All Rights Reserved. Page 14 of 14
Loading...