Atec MT8212E, MT8213E User Manual

Technical Data Sheet
Cell Master
Compact Handheld Base Station Analyzer
MT8212E MT8213E
2 MHz to 4 GHz 2 MHz to 6 GHz Cable & Antenna Analyzer 9 kHz to 4 GHz 9 kHz to 6 GHz Spectrum Analyzer 10 MHz to 4 GHz 10 MHz to 6 GHz Power Meter
Introduction
Anritsu introduces its latest generation compact handheld Base Station Analyzer for installation and maintenance of wireless networks. Designed as a lightweight base station analyzer meeting virtually all the testing needs of an RF technician, the Cell Master features Signal Analyzer options for 2G, 3G, and 4G cellular networks including LTE, WiMAX, and for digital broadcast.
Cable and Antenna Analyzer Highlights Spectrum and Interference Analyzer Highlights
Measurements: RL, VSWR, Cable Loss, DTF, Phase
2-port Transmission Measurement: High/Low Power
Sweep Speed: 1 ms/data point, typical
Display: Single or Dual Measurement Touchscreen
Calibration: OSL, InstaCal™, and FlexCal™
Bias Tee: 32 V internal
Capabilities and Functional Highlights
LTE , TD-LTE (20 MHz B/W)
GSM/EDGE
W-CDMA/HSPA+
TD-SCDMA/HSPA+
CDMA, EV-DO
Fixed, Mobile WiMAX
ISDB-T, ISDB-T SFN
DVB-T/H, DVB-T/H SFN
PIM Analyzer
Interference Analyzer
GPS information on stored
traces
Measurements: Occupied Bandwidth, Channel Power, ACPR, C/I
Interference Analyzer: Spectrogram, Signal Strength, RSSI,
Interference Mapping
Dynamic Range: > 102 dB in 1 Hz RBW
DANL: –162 dBm in 1 Hz RBW
Phase Noise: –100 dBc/Hz max @ 10 kHz offset at 1 GHz
Frequency Accuracy: ± 50 ppb with GPS On
Built-in Bias Tee
Internal Power Meter
High Accuracy Power Meter
USB Power Sensors, 4 GHz to
26 GHz
Coverage Mapping
E1, T1, T3 Backhaul Analyzer
3 hour battery operation time
USB data transfer
Master Software Tools™
Line Sweep Tools™
easyTest Tools™
Cell Master™ MT8212E/MT8213E Base Station Analyzer featuring 8.4 inch Daylight Viewable Touchscreen
Compact Size: 273 mm x 199 mm x 91 mm, (10.7 inch x 7.8 inch x 3.6 inch), Lightweight: 3.71 kg, (8.2 lbs)
Specifications Cell Master™ MT8212E and MT8213E
Cable and Antenna Analyzer
Measurements
Measurements
Setup Parameters
Measurement Display
Frequency
Windowing
Amplitude
Sweep
Data Points
Markers
Tra ce s
Limit Line
Calibration
Save/Recall
Frequency
Frequency Range
Frequency Accuracy≤ ± 2.5 ppm @ 25 ºC
Frequency Resolution
Output Power
Interference Immunity
On-Channel
On-Frequency
Measurement Speed
Return Loss≤ 1.00 ms/data point, RF immunity low, typical
Distance-to-Fault≤ 1.25 ms/data point, RF immunity low, typical
Return Loss
Measurement Range
Resolution
VSWR
Measurement Range
Resolution
Cable Loss
Measurement Range
Resolution
Distance-to-Fault
Vertical Range Return Loss
Vert ic al Range VSW R
Fault Resolution (meters)
Horizontal Range (meters)
1-Port Phase
Measurement Range
Resolution
Smith Chart
Resolution
VSWR Return Loss Cable Loss Distance-to-Fault (DTF) Return Loss Distance-to-Fault (DTF) VSWR 1-Port Phase
Ω
Smith Chart (50/75
Single/Dual Measurement Display with independent markers Start/Stop, Signal Standard, Start Cal
DTF
Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe Top, Bottom Auto Scale, Full Scale Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing,
Output Power (High/Low), RF Pwr When Hold (On/Off) 137, 275, 551, 1102, 2204 Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Peak/Valley Auto,
Marker Table (On/Off ), All Markers Off Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay (On/Off) On/Off, Single Limit, Multi-segment Edit, Limit Alarm (On/Off), Pass Fail Message (On/Off), Pass/Fail
(Unbounded/Bounded), Warning Limit Offset, Clear Limit Start Cal, Cal Type (Standard/FlexCal), Disp Valid Cal Temp Range Setups, Measurements, Screen Shots (.jpg) (save only)
2 MHz to 4 GHz (MT8212E), 2 MHz to 6 GHz (MT8213E)
1 kHz (RF immunity low), 100 kHz (RF immunity high)
High
0 dBm, typical
Low
–30 dBm, typical
+17 dBm @ > 1.0 MHz from carrier frequency 0 dBm within ± 10 kHz of the carrier frequency
0 dB to 60 dB
0.01 dB
1:1 to 65:1
0.01
0 dB to 30 dB
0.01 dB
0 dB to 60 dB 1:1 to 65:1 (1.5 x 108 x vp) / ΔF (vp = velocity propagation constant, ΔF is F2–F1 in Hz) 0 to (Data Points–1) x Fault Resolution, to a maximum of 1500 meters (4921 feet)
–180º to +180º
0.01º
0.01 50/75 Ohm Selectable
selectable)
2 of 32 PN: 11410-00485 Rev. M MT8212E and MT8213E TDS
Cell Master™ MT8212E and MT8213E Specifications
10
1
0.1
-40 -30 -20 Return Loss (dB)
Uncertainity (dB)
-10 0
Reecon Magnitude Uncertainty
< 4 GHz
4 to 6 GHz
100
10
1
-40 -30 -20 Return Loss (dB)
Uncertainity (degrees)
-10 0
Reecon Phase Uncertainty
< 4 GHz
4 to 6 GHz
Cable and Antenna Analyzer (Continued)
Measurement Accuracy
Corrected Directivity
> 42 dB, OSL Calibration > 38 dB, InstaCal™ Calibration
Measurement Uncertainty
PIM Analyzer (Requires PIM Master™)
See Product Brochure 11410-00546
2-Port Transmission Measurement (Option 0021)
Frequency
Frequency Range
Frequency Resolution
2 MHz to 4 GHz (MT8212E), 2 MHz to 6 GHz (MT8213E) 10 Hz
Output Power
High
0 dBm, typical
Low
–30 dBm, typical
High Dynamic Range (On)
2 MHz to 4 GHz 4 GHz to 6 GHz
Application Options
80 dB, 95 dB, typical 70 dB, 85 dB, typical Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Bias-Tee (Option 0010)
Setup
Voltage Range
Current (Low/High)
Resolution
On/Off, Voltage, Current (Low/High) +12 V to +32 V 250 mA/450 mA, 1 A surge for 100 ms
0.1 V
MT8212E and MT8213E TDS PN: 11410-00485 Rev. M 3 of 32
Specifications Cell Master™ MT8212E and MT8213E
Spectrum Analyzer
Measurements
Smart Measurements
Setup Parameters
Frequency
Amplitude
Bandwidth
Save/Recall
Save-on-Event
Delete
Directory Management
Application Options
Sweep Functions
Sweep
Detection
Triggers
Trace Functions
Tra ce s Trace A Operations Trace B OperationsA → Trace C OperationsA →
Marker Functions
Markers
Marker Types
Marker Auto-Position
Marker Table
Limit Line Functions
Limit Lines
Limit Line Edit
Limit Line Move
Limit Line Envelope
Limit Line Advanced
Frequency
Frequency Range
Tuning Resolution
Frequency Reference
Frequency Span
Sweep Time
Sweep Time Accuracy
Bandwidth
Resolution Bandwidth (RBW)
Video Bandwidth (VBW) RBW with Quasi-Peak Detection VBW with Quasi-Peak Detection
Field Strength (uses antenna calibration tables to measure dBm/m2, dBmV/m, dBV/m, dBμV/m, Volt/m,
2
Watt/m
, dBW/m2, A/m, dBA/m and Watt/cm2) Occupied Bandwidth (measures 99 % to 1 % power channel of a signal) Channel Power (measures the total power in a specified bandwidth) ACPR (adjacent channel power ratio) AM/FM/SSB Demodulation (wide/narrow FM, USB and LSB), (audio out only) C/I (carrier-to-interference ratio) Emission Mask Coverage Mapping (requires Option 0431)
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Channel Increment Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span
Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span R B W, A u t o R B W, V B W, A u t o V B W, R BW / VB W, Sp a n/ R BW
File
Save, Recall, Delete, Directory Management Setups, Measurements, Limit Lines, Screen Shots (.jpg) (save only), Save-on-Event Crossing Limit Line, Sweep Complete, Save-then-Stop, Clear All Selected File, All Measurements, All Mode Files, All Content Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy, Format USB Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
Single/Continuous, Sweep Mode (Fast, Performance, No FFT), Reset, Detection, Minimum Sweep Time, Trigger Type, Gated Sweep (see Option 0090)
Peak, RMS, Negative, Sample, Quasi-peak Free Run, External, Video, Change Position, Manual
Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)
B, B ↔ C, Max Hold, Min Hold
C, B ↔ C, Max Hold, Min Hold, A – B → C, B – A → C, Relative Reference (dB), Scale
Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers, Marker Table (On/Off), All Markers Off
Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel, Marker Frequency to
Center, Delta Marker to Span, Marker to Reference Level 1-6 markers frequency and amplitude plus delta markers frequency amplitude and offset
Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1 Create Envelope, Update Amplitude, Points (41 max), Offset, Shape Square/Slope Type (Absolute/Relative), Mirror, Save/Recall
9 kHz to 4 GHz (MT8212E), 9 kHz to 6 GHz (MT8213E) 1 Hz Aging: ± 1.0 ppm/year
Accuracy: ± 1.5 ppm (25 °C ± 25 °C) + aging, < ± 50 ppb with GPS On 10 Hz to 4 GHz including zero span (MT8212E), 10 Hz to 6 GHz including zero span (MT8213E) Minimum 100 ms, 10 µs to 600 s in zero span ± 2 % in zero span
1 Hz to 3 MHz in 1–3 sequence ± 10% (1 MHz max in zero-span) (–3 dB bandwidth) 1 Hz to 3 MHz in 1–3 sequence (–3 dB bandwidth) 200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth) Auto VBW is On, RBW/VBW = 1
4 of 32 PN: 11410-00485 Rev. M MT8212E and MT8213E TDS
Cell Master™ MT8212E and MT8213E Specifications
Spectrum Analyzer (Continued)
Spectral Purity
SSB Phase Noise @ 1 GHz
Amplitude Ranges
Dynamic Range
Measurement Range
Display Range
Reference Level Range
Maximum Continuous Input Power
Attenuator Range
Amplitude Units
Amplitude Accuracy
9 kHz to 100 kHz 100 kHz to 4.0 GHz > 4.0 GHz to 6 GHz
Displayed Average Noise Level (DANL)
(RBW = 1 Hz, 0 dB attenuation) Maximum Typical Maximum Typical
10 MHz to 2.4 GHz –141 dBm –146 dBm –157 dBm –162 dBm
> 2.4 GHz to 4 GHz –137 dBm –141 dBm –154 dBm –159 dBm
> 4 GHz to 5 GHz –134 dBm –138 dBm –150 dBm –155 dBm
> 5 GHz to 6 GHz –126 dBm –131 dBm –143 dBm –150 dBm
–100 dBc/Hz, –110 dBc/Hz typical @ 10 kHz offset –105 dBc/Hz, –112 dBc/Hz typical @ 100 kHz offset –115 dBc/Hz, –121 dBc/Hz typical @ 1 MHz offset
> 102 dB (2.4 GHz), 2/3 (TOI-DANL) in 1 Hz RBW DANL to +26 dBm 1 dB to 15 dB/div in 1 dB steps, ten divisions displayed –120 dBm to +30 dBm +30 dBm 0 dB to 55 dB in 5 dB steps Log Scale Modes: dBm, dBV, dBmV, dBμV, dBW, dBmW, dBμW, dBA, dBmA, dBμA
Linear Scale Modes: nV,
± 2.00 dB typical ± 1.25 dB, ± 0.5 dB typical ± 1.50 dB, ± 0.5 dB typical
(Reference Level –20 dBm)
μ
V, m V, V, kV, n W, μW, m W, W, k W, n A , μA, mA, A
Preamp Off
Preamp On
(Reference Level –50 dBm)
Spurs
Residual Spurious
Input-Related Spurious
Exceptions, typical
Third-Order Intercept (TOI)
800 MHz
2400 MHz
200 MHz to 2200 MHz
> 2.2 GHz to 5.0 GHz > 5.0 GHz to 6.0 GHz
Second Harmonic Distortion
50 MHz
> 50 MHz to 200 MHz
> 200 MHz to 3000 MHz
VSWR
< –90 dBm (RF input terminated, 0 dB input attenuation, > 10 MHz) < –75 dBc (0 dB attenuation, –30 dBm input, span < 1.7 GHz, carrier offset > 4.5 MHz) < –70 dBc @ < 2.5 GHz, with 2072.5 MHz Input
< –68 dBc @ F1 – 280 MHz with F1 Input < –70 dBc @ F1 + 190.5 MHz with F1 Input < –52 dBc @ 7349 – (2F2) MHz, with F2 Input, where F2 < 2424.5 MHz < –55 dBc @ 190.5 ± (F1/2) MHz, where F1 < 1 GHz
Preamp Off (–20 dBm tones 100 kHz apart, 10 dB attenuation) +16 dBm +20 dBm +25 dBm, typical +28 dBm, typical +33 dBm, typical
Preamp Off, 0 dB input attenuation, –30 dBm input –56 dBc –60 dBc, typical –70 dBc, typical
2:1, typical
MT8212E and MT8213E TDS PN: 11410-00485 Rev. M 5 of 32
Specifications Cell Master™ MT8212E and MT8213E
Coverage Mapping (Options 0431)
Measurements
Indoor Mapping Outdoor Mapping
RSSI ACPR
RSSI
ACPR
Setup Parameters
Frequency
Amplitude
Measurement Setup
Point Distance / Time Setup
Save Points Map
Recall Points Map
Center/Start/Stop, Span, Freq Step, Signal Standard, Channel #, Channel Increment Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span
Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
BW
R B W, A u t o R B W, V B W, A u t o V B W, R BW / VB W, Sp a n/ V BW ACPR, RSSI Repeat Type Time Distance Save KML, JPEG, Tab Delimited Recall Map, Recall KML Points only, Recall KML Points with Map, Recall Default Grid
Interference Analyzer (Option 0025)
Measurements
Application Options
Spectrum
Field Strength Occupied Bandwidth Channel Power Adjacent Channel Power Ratio (ACPR) AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only)
Carrier-to-Interference ratio (C/I) Spectrogram (Collect data up to one week) Signal Strength (Gives visual and aural indication of signal strength) Received Signal Strength Indicator (RSSI) (collect data up to one week)
Gives visual and aural indication of signal strength Signal ID (up to 12 signals)
Center Frequency
Bandwidth
Signal Type (FM, GSM, W-CDMA, CDMA, Wi-Fi)
Closest Channel Number
Number of Carriers
Signal-to-Noise Ratio (SNR) > 10 dB Interference Mapping
Triangulate location of interference with on-display maps Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
GPS Receiver Option (Option 0031) (Antenna sold separately)
Setup
GPS Time/Location Indicator
High Frequency Accuracy
Connector
On/Off, Antenna Voltage 3.3/5.0 V, GPS Info Time, Latitude, Longitude and Altitude on display
Time, Latitude, Longitude and Altitude with trace storage Spectrum Analyzer, Interference Analyzer, CW Signal Analyzers
< ± 50 ppb with GPS On, GPS antenna connected, 3 minutes after satellite lock in selected mode
SMA, Female
6 of 32 PN: 11410-00485 Rev. M MT8212E and MT8213E TDS
Cell Master™ MT8212E and MT8213E Specifications
Channel Scanner (Option 0027)
Number of Channels
Measurements
Scanner
Amplitude
Custom Scan
Frequency Range
Frequency Accuracy
Measurement Range
Application Options
1 to 20 Channels Graph/Table, Max Hold (On/5 s/Off ), Freq/Channel, Current/Max, Single/Dual Color Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™ Reference Level, Scale Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan 100 kHz to 4 GHz (MT8212E), 100 kHz to 6 GHz (MT8213E) ± 10 Hz + Time base error –110 dBm to +26 dBm Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
CW Signal Generator (Option 0028) (Requires CW Signal Generator Kit, P/N 69793)
Setup Parameters
Frequency
Amplitude
Frequency Range
Frequency Reference
Output Power
Frequency, Signal Standard, Channel Number, Display Setup Help Power Level (Low/High), Offset (dB) 2 MHz to 2 GHz Accuracy: ± 1.5 ppm (25 °C ± 25 °C) + aging, < ± 50 ppb with GPS On High 0 dBm typical, Low –30 dBm typical Attenuator (included in kit 69793): 0 to 90 dB in 1 dB steps
Gated Sweep (Option 0090)
Mode
Trigger
Setup
Spectrum Analyzer, Sweep External TTL Gated Sweep (On/Off) Gate Polarity (Rising, Falling) Gate Delay (0 ms to 65 ms typical)
Gate Length (1 Zero Span Time
μ
s to 65 ms typical)
MT8212E and MT8213E TDS PN: 11410-00485 Rev. M 7 of 32
Specifications Cell Master™ MT8212E and MT8213E
Power Meter
Frequency
Amplitude
Average
Limits
Frequency Range
Display Range
Measurement Range
Offset Range
VSWR
Maximum Continuous Input Power
Accuracy
Application Options
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Full Band Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale Acquisition Fast/Med/Slow, # of Running Averages Limit On/Off, Limit Upper/Lower 10 MHz to 4 GHz (MT8212E), 10 MHz to 6 GHz (MT8213E)
Span
1 kHz to 100 MHz –140 dBm to +30 dBm, ≤ 40 dB span –120 dBm to +26 dBm 0 dB to +100 dB (External Gain or Loss) 2:1 typical +30 dBm Same as Spectrum Analyzer Impedance (50 Ω, 75 Ω, Other)
High Accuracy Power Meter (Option 0019) (Requires external USB Power Sensor(s))
Amplitude
Average
Zero/Cal
Limits
Power Sensor Model PSN50 MA24104A/05A MA24106A MA24108A/18A/26A
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale # of Running Averages, Max Hold Zero On/Off, Cal Factor (Center Frequency, Signal Standard) Limit On/Off, Limit Upper/Lower
Description High Accuracy
Frequency Range 50 MHz to 6 GHz 600 MHz to 4 GHz
Connector Type N(m), 50
Dynamic Range –30 dBm to +20 dBm
VBW 100 Hz 100 Hz 100 Hz 50 kHz
Measurand True-RMS True-RMS True-RMS True-RMS, Slot Power,
Measurement Uncertainty ± 0.16 dB
(for complete specifications)
Notes:
1. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
2. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results referenced to the input side of the sensor.
3. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
Datasheet
RF Power
(0.001 mW to 100 mW)
Sensor
Ω
1
11410-00414 11410-00483
Inline Bi-Directional
Power Sensor
High
(MA24104A)
350 MHz to 4 GHz
(MA24105A)
Type N(m), 50
(MA24104A)
Type N(f), 50
(MA24105A)
+3 dBm to +51.76 dBm
(2 mW to 150 W)
± 0.17 dB
(MA24104A)
11410-00621
(MA24105A)
Ω
Ω
2
High Accuracy
RF Power
50 MHz to 6 GHz 10 MHz to 8 GHz
Type N(m), 50
–40 dBm to +23 dBm
(0.1 µW to 200 mW)
Sensor
Ω
± 0.16 dB
11410-00424 11410-00504
1
Microwave USB
Sensor
Power
(MA24108A)
10 MHz to 18 GHz
(MA24118A)
10 MHz to 26 GHz
(MA24126A)
Type N(m), 50
(MA24108A/18A)
Type K(m), 50
(MA24126A)
–40 dBm to +20 dBm
(0.1 µW to 100 mW)
Burst Average Power
± 0.18 dB
Ω
Ω
3
8 of 32 PN: 11410-00485 Rev. M MT8212E and MT8213E TDS
Cell Master™ MT8212E and MT8213E Specifications
LTE Signal Analyzers (Options 0541, 0542, 0546, 055 1, 0552, 0556)
Measurements
(Option 0541 FDD) (Option 0551 TDD)
Channel Spectrum
Channel Power Occupied Bandwidth
Power vs. Time (TDD only)
Frame View Sub-Frame View Total Frame Power DwPTS Power Transmit Off Power Cell ID
Timing Error ACPR Spectral Emission Mask
Category A or B (Opt 1) RF Summary
RF
Power vs. Resource Block (RB)
Constellation
Control Channel Power
Tx Time Alignment (FDD only) Modulation Summary
Antenna Icons
Demodulation (Option 0542 FDD) (Option 0552 TDD)
RB Power (PDSCH) Active RBs, Utilization %, Channel Power, Cell ID OSTP, Frame EVM by modulation
(FDD only)
QPSK, 16 QAM, 64 QAM Modulation Results
Ref Signal Power (RS) Sync Signal Power (SS) EVM – rms, peak, max hold Frequency Error – Hz, ppm Carrier Frequency Cell ID
Bar Graph or Table View RS, P-SS, S-SS PBCH, PCFICH PHICH, PDCCH (FDD only) Total Power (Table View) EVM (FDD only) Modulation Results
Includes EVM by modulation (FDD only)
Detects active antennas (1/2)
Over-the-Air (OTA)
(Option 0546 FDD)
(Option 0556 TDD)
Scanner
Cell ID (Group, Sector) S-SS Power, RSRP, RSRQ, SINR Dominance Modulation Results – On/Off
Tx Test
Scanner RS Power of MIMO antennas
Cell ID, Average Power Delta Power (Max-Min) Graph of Antenna Power Modulation Results – On/Off
Mapping
On-screen
S-SS Power, RSRP, RSRQ, or SINR
Scanner
Modulation Results – Off
Pass/Fail
(User Editable)
View Pass/Fail Limits
All, RF, Modulation
Available Measurements
Channel Power Occupied Bandwidth ACLR Frequency Error Carrier Frequency Dominance EVM peak, rms RS Power RS EVM (FDD only) SS, P-SS, S-SS Power SS, P-SS, S-SS EVM (FDD only) PBCH Power PBCH EVM (FDD only) PCFICH Power PCFICH EVM (FDD only) PHICH Power, EVM (FDD only) PDCCH Power, EVM (FDD only) Cell, Group, Sector ID OSTP (FDD only) Tx Time Alignment (FDD only) Frame Power (TDD only) DwPTS Power (TDD only) Transmit Off Power (TDD only) Timing Error (TDD only)
Setup Parameters
Frequency
Bandwidth
Amplitude
Sweep
EVM Mode
Save/Recall
Measurement Summary Screens
E-UTRA FDD bands 1 – 5, 7 – 14, 17 – 21, 23 – 25 (tunable 10 MHz to 4.0 GHz) E-UTRA TDD bands 33 – 43 (tunable 10 MHz to 4.0 GHz) Center, Signal Standard, Channel #, Closest Channel, Decrement/Increment Channel
1.4, 3, 5, 10, 15, 20 MHz
Span
Auto, 1.4, 3, 5, 10, 15, 20, 30 MHz Scale/Division, Power Offset, Auto Range, Adjust Range Single/Continuous, Trigger Sweep Auto, PBCH only Setup, Measurement, Screen Shot (save only), to Internal/External Memory Overall Measurements, RF Measurements, Modulation Measurements
RF Measurements (Options 0541, 0551)
RF Channel Power Accuracy
± 1.5 dB, ± 1.0 dB typical, (RF input –50 dBm to +10 dBm) (Option 0541) ± 1.5 dB, ± 1.0 dB typical, (RF input –30 dBm to +10 dBm) (Option 0551)
Demodulation Measurements (Options 0542, 0552)
Frequency Error
Residual EVM (rms) (FDD only)
Residual EVM (rms) (TDD only)
± 10 Hz + time base error, 99 % confidence level
2.0% typical (E-UTRA Test Model 3.1, RF Input –50 dBm to +10 dBm) for BW ≤ 10 MHz
2.5% typical (E-UTRA Test Model 3.1, RF Input –50 dBm to +10 dBm) for BW > 10 MHz
2.0% typical (E-UTRA Test Model 3.1, RF Input –30 dBm to +10 dBm) for BW ≤ 10 MHz
2.5% typical (E-UTRA Test Model 3.1, RF Input –30 dBm to +10 dBm) for BW > 10 MHz
Over-the-Air (OTA) Measurements (Options 0546, 0556)
Scanner
Auto Save
Mapping
Six strongest signals if present Auto Save — Sync Signal Power and Modulation Results with GPS information
Scanner — three strongest signals if present RS Power — strongest signal
Map On-screen S-SS Power, RSRP, RSRQ, or SINR of Cell ID with strongest signal Scanner — three strongest signals if present Save and Export Scanner data: *.kml, *.mtd (tab delimited)
MT8212E and MT8213E TDS PN: 11410-00485 Rev. M 9 of 32
Specifications Cell Master™ MT8212E and MT8213E
GSM/EDGE Signal Analyzers (Options 0040, 0041)
Measurements
RF
(Option 0040)
Channel Spectrum
Channel Power Occupied Bandwidth Burst Power Average Burst Power Frequency Error Modulation Type
BSIC (NCC, BCC) Multi-channel Spectrum Power vs. Time (Frame/Slot)
Channel Power
Occupied Bandwidth
Burst Power
Average Burst Power
Frequency Error
Modulation Type
BSIC (NCC, BCC)
Phase Error EVM Origin Offset C/I Modulation Type Magnitude Error BSIC (NCC, BCC)
Setup Parameters
GSM/EDGE Select
Frequency
Amplitude
Sweep
Save/Recall
Measurement Summary Screens
RF Measurements (Option 0040) (Temperature range 15 ºC to 35 ºC)
Frequency Error
Occupied Bandwidth
Burst Power Error
Demodulation (Option 0041) (Temperature range 15 ºC to 35 ºC)
GSMK Modulation Quality (RMS Phase)
8 PSK Modulation Quality (EVM)
Measurement Accuracy
Residual Error (GSMK)
Measurement Accuracy
Residual Error (8 PSK)
Demodulation (Option 0041) Over-the-Air (OTA)
There are no additional OTA Measurements.
RF and Demodulation measurements can be made OTA
Auto, GSM, EDGE Center, Signal Standard, Channel #, Closest Channel, Decrement/Increment Channel Power Offset, Auto Range, Adjust Range Single/Continuous, Trigger Sweep Setup, Measurement, Screen Shot (save only), to Internal/External Memory Overall Measurements
± 10 Hz + time base error, 99 % confidence level Bandwidth within which 99 % of the power transmitted on a single channel lies ± 1.5 dB, ± 1 dB typical, (–50 dBm to +20 dBm)
± 1 deg 1 deg
± 1.5 %
2.5 %
Channel Power Occupied Bandwidth Burst Power Average Burst Power Frequency Error Phase Error EVM Origin Offset C/I Magnitude Error
Pass/Fail
(User Editable)
10 of 32 PN: 11410-00485 Rev. M MT8212E and MT8213E TDS
Loading...
+ 22 hidden pages