2 MHz to 4 GHz2 MHz to 6 GHzCable & Antenna Analyzer
9 kHz to 4 GHz9 kHz to 6 GHzSpectrum Analyzer
10 MHz to 4 GHz10 MHz to 6 GHzPower Meter
Introduction
Anritsu introduces its latest generation compact handheld Base Station Analyzer for installation and maintenance of wireless networks. Designed
as a lightweight base station analyzer meeting virtually all the testing needs of an RF technician, the Cell Master features Signal Analyzer options
for 2G, 3G, and 4G cellular networks including LTE, WiMAX, and for digital broadcast.
Cable and Antenna Analyzer HighlightsSpectrum and Interference Analyzer Highlights
• Interference Analyzer: Spectrogram, Signal Strength, RSSI,
Interference Mapping
• Dynamic Range: > 102 dB in 1 Hz RBW
• DANL: –162 dBm in 1 Hz RBW
• Phase Noise: –100 dBc/Hz max @ 10 kHz offset at 1 GHz
• Frequency Accuracy: ± 50 ppb with GPS On
• Built-in Bias Tee
• Internal Power Meter
• High Accuracy Power Meter
• USB Power Sensors, 4 GHz to
26 GHz
• Coverage Mapping
• E1, T1, T3 Backhaul Analyzer
• 3 hour battery operation time
• USB data transfer
• Master Software Tools™
• Line Sweep Tools™
• easyTest Tools™
Cell Master™ MT8212E/MT8213E Base Station Analyzer featuring 8.4 inch Daylight Viewable Touchscreen
Compact Size: 273 mm x 199 mm x 91 mm, (10.7 inch x 7.8 inch x 3.6 inch), Lightweight: 3.71 kg, (8.2 lbs)
SpecificationsCell Master™ MT8212E and MT8213E
Cable and Antenna Analyzer
Measurements
Measurements
Setup Parameters
Measurement Display
Frequency
Windowing
Amplitude
Sweep
Data Points
Markers
Tra ce s
Limit Line
Calibration
Save/Recall
Frequency
Frequency Range
Frequency Accuracy≤ ± 2.5 ppm @ 25 ºC
Frequency Resolution
Output Power
Interference Immunity
On-Channel
On-Frequency
Measurement Speed
Return Loss≤ 1.00 ms/data point, RF immunity low, typical
Distance-to-Fault≤ 1.25 ms/data point, RF immunity low, typical
Return Loss
Measurement Range
Resolution
VSWR
Measurement Range
Resolution
Cable Loss
Measurement Range
Resolution
Distance-to-Fault
Vertical Range Return Loss
Vert ic al Range VSW R
Fault Resolution (meters)
Horizontal Range (meters)
1-Port Phase
Measurement Range
Resolution
Smith Chart
Resolution
VSWR
Return Loss
Cable Loss
Distance-to-Fault (DTF) Return Loss
Distance-to-Fault (DTF) VSWR
1-Port Phase
Ω
Smith Chart (50/75
Single/Dual Measurement Display with independent markers
Start/Stop, Signal Standard, Start Cal
DTF
Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing
Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Top, Bottom Auto Scale, Full Scale
Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing,
Output Power (High/Low), RF Pwr When Hold (On/Off)
137, 275, 551, 1102, 2204
Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Peak/Valley Auto,
Marker Table (On/Off ), All Markers Off
Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay (On/Off)
On/Off, Single Limit, Multi-segment Edit, Limit Alarm (On/Off), Pass Fail Message (On/Off), Pass/Fail
(Unbounded/Bounded), Warning Limit Offset, Clear Limit
Start Cal, Cal Type (Standard/FlexCal), Disp Valid Cal Temp Range
Setups, Measurements, Screen Shots (.jpg) (save only)
2 MHz to 4 GHz (MT8212E), 2 MHz to 6 GHz (MT8213E)
+17 dBm @ > 1.0 MHz from carrier frequency
0 dBm within ± 10 kHz of the carrier frequency
0 dB to 60 dB
0.01 dB
1:1 to 65:1
0.01
0 dB to 30 dB
0.01 dB
0 dB to 60 dB
1:1 to 65:1
(1.5 x 108 x vp) / ΔF (vp = velocity propagation constant, ΔF is F2–F1 in Hz)
0 to (Data Points–1) x Fault Resolution, to a maximum of 1500 meters (4921 feet)
–180º to +180º
0.01º
0.01 50/75 Ohm Selectable
selectable)
2 of 32PN: 11410-00485 Rev. MMT8212E and MT8213E TDS
On/Off, Voltage, Current (Low/High)
+12 V to +32 V
250 mA/450 mA, 1 A surge for 100 ms
0.1 V
MT8212E and MT8213E TDSPN: 11410-00485 Rev. M3 of 32
SpecificationsCell Master™ MT8212E and MT8213E
Spectrum Analyzer
Measurements
Smart Measurements
Setup Parameters
Frequency
Amplitude
Bandwidth
Save/Recall
Save-on-Event
Delete
Directory Management
Application Options
Sweep Functions
Sweep
Detection
Triggers
Trace Functions
Tra ce s
Trace A Operations
Trace B OperationsA →
Trace C OperationsA →
Marker Functions
Markers
Marker Types
Marker Auto-Position
Marker Table
Limit Line Functions
Limit Lines
Limit Line Edit
Limit Line Move
Limit Line Envelope
Limit Line Advanced
Frequency
Frequency Range
Tuning Resolution
Frequency Reference
Frequency Span
Sweep Time
Sweep Time Accuracy
Bandwidth
Resolution Bandwidth (RBW)
Video Bandwidth (VBW)
RBW with Quasi-Peak Detection
VBW with Quasi-Peak Detection
Field Strength (uses antenna calibration tables to measure dBm/m2, dBmV/m, dBV/m, dBμV/m, Volt/m,
2
Watt/m
, dBW/m2, A/m, dBA/m and Watt/cm2)
Occupied Bandwidth (measures 99 % to 1 % power channel of a signal)
Channel Power (measures the total power in a specified bandwidth)
ACPR (adjacent channel power ratio)
AM/FM/SSB Demodulation (wide/narrow FM, USB and LSB), (audio out only)
C/I (carrier-to-interference ratio)
Emission Mask
Coverage Mapping (requires Option 0431)
Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations
Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)
B, B ↔ C, Max Hold, Min Hold
C, B ↔ C, Max Hold, Min Hold, A – B → C, B – A → C, Relative Reference (dB), Scale
Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers, Marker
Table (On/Off), All Markers Off
Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker
Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel, Marker Frequency to
Center, Delta Marker to Span, Marker to Reference Level
1-6 markers frequency and amplitude plus delta markers frequency amplitude and offset
Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit
Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right
To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1
Create Envelope, Update Amplitude, Points (41 max), Offset, Shape Square/Slope
Type (Absolute/Relative), Mirror, Save/Recall
9 kHz to 4 GHz (MT8212E), 9 kHz to 6 GHz (MT8213E)
1 Hz
Aging: ± 1.0 ppm/year
Accuracy: ± 1.5 ppm (25 °C ± 25 °C) + aging, < ± 50 ppb with GPS On
10 Hz to 4 GHz including zero span (MT8212E), 10 Hz to 6 GHz including zero span (MT8213E)
Minimum 100 ms, 10 µs to 600 s in zero span
± 2 % in zero span
1 Hz to 3 MHz in 1–3 sequence ± 10% (1 MHz max in zero-span) (–3 dB bandwidth)
1 Hz to 3 MHz in 1–3 sequence (–3 dB bandwidth)
200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth)
Auto VBW is On, RBW/VBW = 1
4 of 32PN: 11410-00485 Rev. MMT8212E and MT8213E TDS
Cell Master™ MT8212E and MT8213ESpecifications
Spectrum Analyzer (Continued)
Spectral Purity
SSB Phase Noise @ 1 GHz
Amplitude Ranges
Dynamic Range
Measurement Range
Display Range
Reference Level Range
Maximum Continuous Input Power
Attenuator Range
Amplitude Units
Amplitude Accuracy
9 kHz to 100 kHz
100 kHz to 4.0 GHz
> 4.0 GHz to 6 GHz
Displayed Average Noise Level (DANL)
(RBW = 1 Hz, 0 dB attenuation)MaximumTypicalMaximumTypical
10 MHz to 2.4 GHz–141 dBm–146 dBm–157 dBm–162 dBm
> 2.4 GHz to 4 GHz–137 dBm–141 dBm–154 dBm–159 dBm
> 102 dB (2.4 GHz), 2/3 (TOI-DANL) in 1 Hz RBW
DANL to +26 dBm
1 dB to 15 dB/div in 1 dB steps, ten divisions displayed
–120 dBm to +30 dBm
+30 dBm
0 dB to 55 dB in 5 dB steps
Log Scale Modes: dBm, dBV, dBmV, dBμV, dBW, dBmW, dBμW, dBA, dBmA, dBμA
Linear Scale Modes: nV,
± 2.00 dB typical
± 1.25 dB, ± 0.5 dB typical
± 1.50 dB, ± 0.5 dB typical
(Reference Level –20 dBm)
μ
V, m V, V, kV, n W, μW, m W, W, k W, n A , μA, mA, A
Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
BW
R B W, A u t o R B W, V B W, A u t o V B W, R BW / VB W, Sp a n/ V BW
ACPR, RSSI
Repeat Type Time Distance
Save KML, JPEG, Tab Delimited
Recall Map, Recall KML Points only, Recall KML Points with Map, Recall Default Grid
Interference Analyzer (Option 0025)
Measurements
Application Options
Spectrum
Field Strength
Occupied Bandwidth
Channel Power
Adjacent Channel Power Ratio (ACPR)
AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only)
Carrier-to-Interference ratio (C/I)
Spectrogram (Collect data up to one week)
Signal Strength (Gives visual and aural indication of signal strength)
Received Signal Strength Indicator (RSSI) (collect data up to one week)
Gives visual and aural indication of signal strength
Signal ID (up to 12 signals)
Center Frequency
Bandwidth
Signal Type (FM, GSM, W-CDMA, CDMA, Wi-Fi)
Closest Channel Number
Number of Carriers
Signal-to-Noise Ratio (SNR) > 10 dB
Interference Mapping
Triangulate location of interference with on-display maps
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
GPS Receiver Option (Option 0031) (Antenna sold separately)
Setup
GPS Time/Location Indicator
High Frequency Accuracy
Connector
On/Off, Antenna Voltage 3.3/5.0 V, GPS Info
Time, Latitude, Longitude and Altitude on display
Time, Latitude, Longitude and Altitude with trace storage
Spectrum Analyzer, Interference Analyzer, CW Signal Analyzers
< ± 50 ppb with GPS On, GPS antenna connected, 3 minutes after satellite lock in selected mode
SMA, Female
6 of 32PN: 11410-00485 Rev. MMT8212E and MT8213E TDS
Cell Master™ MT8212E and MT8213ESpecifications
Channel Scanner (Option 0027)
Number of Channels
Measurements
Scanner
Amplitude
Custom Scan
Frequency Range
Frequency Accuracy
Measurement Range
Application Options
1 to 20 Channels
Graph/Table, Max Hold (On/5 s/Off ), Freq/Channel, Current/Max, Single/Dual Color
Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™
Reference Level, Scale
Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan
100 kHz to 4 GHz (MT8212E), 100 kHz to 6 GHz (MT8213E)
± 10 Hz + Time base error
–110 dBm to +26 dBm
Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)
CW Signal Generator (Option 0028) (Requires CW Signal Generator Kit, P/N 69793)
Setup Parameters
Frequency
Amplitude
Frequency Range
Frequency Reference
Output Power
Frequency, Signal Standard, Channel Number, Display Setup Help
Power Level (Low/High), Offset (dB)
2 MHz to 2 GHz
Accuracy: ± 1.5 ppm (25 °C ± 25 °C) + aging, < ± 50 ppb with GPS On
High 0 dBm typical, Low –30 dBm typical
Attenuator (included in kit 69793): 0 to 90 dB in 1 dB steps
Gated Sweep (Option 0090)
Mode
Trigger
Setup
Spectrum Analyzer, Sweep
External TTL
Gated Sweep (On/Off)
Gate Polarity (Rising, Falling)
Gate Delay (0 ms to 65 ms typical)
Gate Length (1
Zero Span Time
μ
s to 65 ms typical)
MT8212E and MT8213E TDSPN: 11410-00485 Rev. M7 of 32
SpecificationsCell Master™ MT8212E and MT8213E
Power Meter
Frequency
Amplitude
Average
Limits
Frequency Range
Display Range
Measurement Range
Offset Range
VSWR
Maximum Continuous Input Power
Accuracy
Application Options
Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #, Full Band
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Acquisition Fast/Med/Slow, # of Running Averages
Limit On/Off, Limit Upper/Lower
10 MHz to 4 GHz (MT8212E), 10 MHz to 6 GHz (MT8213E)
Span
1 kHz to 100 MHz
–140 dBm to +30 dBm, ≤ 40 dB span
–120 dBm to +26 dBm
0 dB to +100 dB (External Gain or Loss)
2:1 typical
+30 dBm
Same as Spectrum Analyzer
Impedance (50 Ω, 75 Ω, Other)
High Accuracy Power Meter (Option 0019) (Requires external USB Power Sensor(s))
Amplitude
Average
Zero/Cal
Limits
Power Sensor ModelPSN50MA24104A/05AMA24106AMA24108A/18A/26A
Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
# of Running Averages, Max Hold
Zero On/Off, Cal Factor (Center Frequency, Signal Standard)
Limit On/Off, Limit Upper/Lower
1. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
2. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results
referenced to the input side of the sensor.
3. Expanded uncertainty with K = 2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
Datasheet
RF Power
(0.001 mW to 100 mW)
Sensor
Ω
1
11410-0041411410-00483
Inline Bi-Directional
Power Sensor
High
(MA24104A)
350 MHz to 4 GHz
(MA24105A)
Type N(m), 50
(MA24104A)
Type N(f), 50
(MA24105A)
+3 dBm to +51.76 dBm
(2 mW to 150 W)
± 0.17 dB
(MA24104A)
11410-00621
(MA24105A)
Ω
Ω
2
High Accuracy
RF Power
50 MHz to 6 GHz10 MHz to 8 GHz
Type N(m), 50
–40 dBm to +23 dBm
(0.1 µW to 200 mW)
Sensor
Ω
± 0.16 dB
11410-0042411410-00504
1
Microwave USB
Sensor
Power
(MA24108A)
10 MHz to 18 GHz
(MA24118A)
10 MHz to 26 GHz
(MA24126A)
Type N(m), 50
(MA24108A/18A)
Type K(m), 50
(MA24126A)
–40 dBm to +20 dBm
(0.1 µW to 100 mW)
Burst Average Power
± 0.18 dB
Ω
Ω
3
8 of 32PN: 11410-00485 Rev. MMT8212E and MT8213E TDS
Six strongest signals if present
Auto Save — Sync Signal Power and Modulation Results with GPS information
Scanner — three strongest signals if present
RS Power — strongest signal
Map On-screen S-SS Power, RSRP, RSRQ, or SINR of Cell ID with strongest signal
Scanner — three strongest signals if present
Save and Export Scanner data: *.kml, *.mtd (tab delimited)
MT8212E and MT8213E TDSPN: 11410-00485 Rev. M9 of 32
SpecificationsCell Master™ MT8212E and MT8213E
GSM/EDGE Signal Analyzers (Options 0040, 0041)
Measurements
RF
(Option 0040)
Channel Spectrum
Channel Power
Occupied Bandwidth
Burst Power
Average Burst Power
Frequency Error
Modulation Type
BSIC (NCC, BCC)
Multi-channel Spectrum
Power vs. Time (Frame/Slot)
RF Measurements (Option 0040) (Temperature range 15 ºC to 35 ºC)
Frequency Error
Occupied Bandwidth
Burst Power Error
Demodulation (Option 0041) (Temperature range 15 ºC to 35 ºC)
GSMK Modulation Quality (RMS Phase)
8 PSK Modulation Quality (EVM)
Measurement Accuracy
Residual Error (GSMK)
Measurement Accuracy
Residual Error (8 PSK)
Demodulation
(Option 0041)Over-the-Air (OTA)
There are no additional OTA
Measurements.
RF and Demodulation
measurements can be made OTA
Auto, GSM, EDGE
Center, Signal Standard, Channel #, Closest Channel, Decrement/Increment Channel
Power Offset, Auto Range, Adjust Range
Single/Continuous, Trigger Sweep
Setup, Measurement, Screen Shot (save only), to Internal/External Memory
Overall Measurements
± 10 Hz + time base error, 99 % confidence level
Bandwidth within which 99 % of the power transmitted on a single channel lies
± 1.5 dB, ± 1 dB typical, (–50 dBm to +20 dBm)
± 1 deg
1 deg
± 1.5 %
2.5 %
Channel Power
Occupied Bandwidth
Burst Power
Average Burst Power
Frequency Error
Phase Error
EVM
Origin Offset
C/I
Magnitude Error
Pass/Fail
(User Editable)
10 of 32PN: 11410-00485 Rev. MMT8212E and MT8213E TDS
Loading...