Atec MSO4000 User Manual

Mixed Signal Oscilloscopes
MSO4000 Series, DPO4000 Series Data Sheet
Connectivity
USB 2.0 Host P for Quick and Easy Data Storage, Printing, and Connecting a USB Keyboard
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Print
Integrated 10/100 Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector
Optional Serial Triggering and Analysis
Automated Serial Triggering, Decode, and Search Options for I2C, SPI, USB, CAN, LIN, FlexRay, RS-232/422/485/UART, and I
ort on the Front Panel and Two on the Rear Panel
ingtoaPictBridge
®
-compatible Printer
2
S/LJ/RJ/TDM
Features & Benets
Key Performance Specications
1 GHz, 500 MHz, 350 MHz Bandwidth Models
4 Analog Channel Models
16 Digital Channels (MSO Series)
Up to 5 GS/s Sample Rate on All Channels
>50,000 wfm/s M aximum Waveform Capture Rate
Suite of Advanced Triggers
Ease of Use Features
Wave Inspector®Controls provide Easy Navigation and Automated Search of Waveform Data
29 Automated Measurements, Waveform Histograms, and FFT Analysis for Simplied Waveform Analysis
TekVPI®Probe Interface supports Active, Differential, and Current Probes for Automatic Scaling and Units
10.4 in. (264 mm) XGA Color Display
Small Footprint and Lightweight – Only 5.4 in. (137 mm) deep and 11 lb. (5 kg)
Mixed Signal Design and Analysis (MSO Series)
Automated Triggering, Decode, and Search on Parallel Buses
Per-channel Threshold Settings
Multichannel Setup and Hold Triggering
MagniVu™ High-speed Acquisition Provides 60.6 ps Fine Timing Resolution on Digital Channels
Optional Application Support
Power A na
HDTV and Custom Video Ana lysis
lysis
Feature-rich Tools for Debugging Mixed Signal Designs
With the M analyze up to 20 analog and digital signals with a single instrument to quickly nd and diagnose problems in complex designs. Bandwidths up to 1 GHz and a minimum of 5x oversampling on all channels ensure you have the performance you need to see fast-changing signal details. To capture long windows of signal activity while maintaining ne timing resolution, the MSO/DPO channels.
With Wav serial and parallel bus analysis, and automated power analysis – the MSO/DPO4000 Oscilloscope Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design.
SO/DPO4000 Mixed Signal Oscilloscope Series, you can
4000 offers a deep record len gth of 10M po ints standard on all
e Inspector
®
controls for rapid waveform navigation, automated
Data Sheet
Discover – of capturi
Fast waveform capture rate - over 50,000 wfm/s - maximizes the probability
ng elusive glitches and other infrequent events.
Comprehensive Features Speed Every Stage of Debug
The MSO/DPO4000 Series offers a robust set of features to speed every stage of debugging your design – from quickly discovering an anomaly and capturing it, to se arching your waveform record for the event and analyzing its characteristics and your device’s behavior.
Discover
To debug a design problem, rst you must know it exists. E very design engineer spends time looking for problems in their design, a time-consuming and frustrating task without the right debug tools.
The MSO/DPO4000 Series o ffers the industry’s most complete visualization of signals, providing fast insight into the real operation of yo ur device. A fast waveform capture rate - greater than 50,000 waveforms per second ­enables you to see glitches and other infrequent transients within seconds,
ing the true nature of device faults. A digital phosphor disp lay with
reveal intensity grading shows the history of a signal’s activity by intensifying areas of the signal that occur more frequently, providing a visual display of just how often anomalies occur.
Capture – T complete s quickly ca
riggering on a specic transmit data packet going across an RS-232 bus. A
et of triggers, including triggers for specic serial packet content, ensures you
pture your event of interest.
Capture
Discovering a device fault is only the rst step. Next, you must capture the event of interest to identify root cause.
The MSO/DPO4000 Series provides a complete set of triggers - including runt, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel data - to help quickly nd your event. With up to a 10M point record length, you can capture many events of interest, even thousands of serial packets, in a single acquisition for further analysis while maintaining high resolution to zoom in
on ne signal details.
From triggering on specic packet content to automatic decode in multiple
mats, the MSO/DPO4000 Series provides integrated support for
data for the industry’s broadest range of serial buses – I FlexRay, RS-232/422/485/UART, and I
2
2
C, SPI, USB, CAN, LIN,
S/LJ/RJ/TDM. The ability to decode up to four serial and/or parallel buses simultaneously means you gain insight into system-level problems quickly.
To f urther help troubleshoot system-level interactions in complex embedded systems, the MSO4000 Series offers 16 digital channels in addition to its analog channels. Since the digital c hannels are fully integrated into the
scope, you can trigger across all input channels, automatically time
oscillo correlating all analog, digital, and serial signals. The MagniVu™ high-speed acquisition enables you to acquire ne signal detail (up to 60.6 ps resolution) around the trigger point for precision measurements. MagniVu is essential for making accurate timing measurements for setup and hold measurements, clock delay, signal skew, and glitch characterization.
2 www.tektronix.com
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
Search–I2C decode showing results from a Wave Inspector search for Address value
50. Wave Inspector controls provide unprecedented efciency in viewing and navigating waveform data.
Search
Finding your event of interest in a long waveform record can be time consuming without the right search tools. With today’s record lengths pushing beyond a million data points, locating your event can mean scrolling through thousands of screens of signal activity.
The MSO/DPO4000 Series offers the industry’s m o st comprehensive search and waveform navigation with its innovative Wave Inspector
®
controls. These controls speed panning and zooming through your record. With a unique force-feedback system, you can move from one end of your
o the other in just seconds. User marks allow you to mark any
record t location that you may want to reference later for further investigation. Or, automatically search your record for criteria you dene. Wave Inspector will instantly search your entire record, including analog, digital, and serial bus data. Along the way it will automatically mark every occurrence of your dened event so you can quickly move between events.
Analyze – W (jitter) o data. A com performan
aveform histogram of a falling edge showing the distribution of edge position
ver time. Included are numeric measurements made on the waveform histogram
prehensive set of integrated analysis tools speeds verication of your design’s
ce.
Analyze
Verifying that your prototype’s performance m atches simulations and meets the project’s design goals requires analyzing its behavior. Tasks can range from simple checks of rise times and pulse widt hs to sophisticated power loss analysis and investigation of noise sources.
The MSO/DPO4000 Series offers a compre hensive set of integrated analysis tools including waveform- and screen-based cursors, 29 automated measurements, advanced waveform math including arbitrary
n editing, waveform histograms, FFT analysis, and trend plots for
equatio visually determining how a measurement is changing over time. Specialized application support for serial bus analysis, power supply design, and video design and development is also available.
For extended analysis, National Instrument’s LabVIEW SignalExpress™ Tektronix Edition provides over 200 built-in functions including time and frequency domain analysis, limit testing, data logging, and customizable reports.
www.tektronix.com 3
Data Sheet
Wave Inspector controls provide unprecedented efciency in viewing, navigating, and analyzing waveform data. Zip through your 10M point record by turning the outer pan control (1). Get from the beginning to end in seconds. See something of interest and want to see more details? Just turn the inner zoom control (2).
Wave Inspector®Navigation and Search
A 10M point record length represents thousands of screens of information. The MSO/DPO4000 Series enables you to nd your event in seconds with Wave Inspector, the industry’s best tool for navigation and search.
Wave Inspector offers the following innovative controls:
Zoom/Pan
A dedicated, two-tier front-panel control provides intuitive c ontrol of both zooming and panning. The inner control adjusts the zoom factor (or zoo m scale); turning it clockwise activates zoom and goes to progressively higher zoom factors, while turning it counterclockwise results in lowe r zoom factors and eventually turning zoo m off. No longer do you need to navigate through
le menus to adjust your zoom view. The outer control pans the zoom
multip box across the waveform to quickly get to the portion of waveform you are interested in. The outer control also utilizes force feedback to determine how fast to pan on the waveform. The farther you turn the oute r control, the faster the zoom box moves. Pan direction is changed by simply turning the control the other way.
Play/Pause
A dedicated Play/Pause front-panel button scrolls the waveform across the display automatically while you look for anomalies or an event of int erest. Playback speed and direction are controlled using the intuitive pan control. Once again, turning the control further makes the waveform scroll faster and
ing direction is as simple as turning the control the other way.
chang
Search ste
Search step 2: Wave Inspector automatically searches through the record and marks each event with a hollow white triangle. You can then use the Previous and Next buttons to jump from one event to the next.
p 1: You dene what you would like to nd.
User Marks
Press the Set Mark front-panel button to place one or more marks on the waveform. Navigating between marks is as simple as pressing the Previous ()andNext () buttons on the front panel.
Search Marks
The Search button allows you to automatically search through your lon g acquisition looking for user-dened events. All occurrences of the event are highlighted with search marks and are easily navigated to, using the front-panel Previous () and Next () buttons. Search types include
, pulse width/glitch, runt, logic, setup and hold, rise/fall time parallel
edge bus, and I
2
I
2
C, SPI, USB, CAN, LIN, FlexRay, RS-232/422/485/UART, and
S/LJ/RJ/TDM packet content.
4 www.tektronix.com
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
osphor technology enables greater than 50,000 wfm/s waveform capture rate
Digital ph
ime intensity grading on the MSO/DPO4000 Series.
and real-t
Digital Phosphor Technology
The MSO/DPO4000 Series’ digital phosphor technology provides you with fast insight into the real operation of your device. Its fast waveform capture rate - greater than 50,000 wfm/s - gives you a high probability of quickly seeing the infrequent problems commo n in digital systems: runt pulses, glitches, timing issues, and more.
Waveforms are superimposed with one another and waveform points that occur more frequently are intensied . This quickly highlights the events
r time occur more often or, in the case of infrequent anomalies,
that ove occur less often.
With the
MSO/DPO4000 Series, you can choose innite persistence or variable persistence, determining how long the previous waveform acquisitions stay on-screen. This allows you to determine how often an anomaly is occurring.
Mixed Signal Design and Analysis (MSO Series)
The MSO4000 Series Mixed Signal Oscilloscopes provide 16 digital channels. These channels are tightly integrated into the oscilloscope’s user
ace, simplifying operation and making it possible to solve mixed-signal
interf issues easily.
The MSO Ser time-corr
With the color-coded digital waveform display, groups are created by simply placing digital channels t ogether on the screen, allowing the digital channels to be moved as a group. You can set threshold values for each channel, enabling support for up to 16 different logic families.
Colo
ies provides 16 integrated digital channels enabling you to view and analyze
elated analog and digital signals.
r-coded Digital Waveform Display
The MSO4000 Series has redened the way you view digital waveforms.
ommon problem shared by both logic analyzers and mixed signal
One c oscilloscopes is determining if data is a one or a zero when zo omed in far enough that the digital trace stays at all the way across the display. The MSO4000 Series has color-coded digital tra ces, displaying ones in green and zeros in blue.
www.tektronix.com 5
Data Sheet
White edges indicate additional information is available by zooming in. As shown here, zooming in on the white edge reveals a hidden glitch.
The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to make critical timing measurements on your digital waveforms.
The multiple transition detection hardware of the MSO4000 Series will show you a white edge on the display when the system detects multiple transitions. White edges indicate that more information is available by zooming in or acquiring at faster sampling rates. In most cases zooming in
veal the pulse that was not viewable with the previous settings. If the
will re white edge is still present after zooming in as far as possible, this indicates that increasing the sample rate on the next acquisition will reveal higher frequency information than the previous settings could acquire.
The P6516 M device.
SO probe offers two eight-channel pods to simplify connecting to your
The MSO4000 Series simplies chan nel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard. By simply placing digital waveforms next to each other, they form a group. Once a group is formed, you can position all the channels contained in that group col
lectively. This greatly reduces the normal setup time associated
with positioning channels individually.
MagniVu™ High-speed Acquisition
Themaind
igital acquisition mode on the MSO4000 Series will capture up to 10M points at 500 MS/s (2 ns resolution). In addition to the main record, the MSO4000 provides an ultra high-resolution record called MagniVu which acquires 10,000 points at up to 16.5 GS/s (60.6 ps resolution). Both main and MagniVu waveforms are acquired on every trigger and can be switched between in the display at any time, running or stopped. MagniVu provides
antly ner timing resolution than comparable MSOs on the market,
signific instilling condence when making critical timing measurements on digital waveforms.
P6516 MSO Probe
This unique probe d esign offers two eight-channel pods. Each channel ends with a probe tip featuring a recessed ground for simplied connection to the device under test. The coax on the rst channel of each pod is colored blue making it easy to identify. The common ground uses an automotive-style connector making it easy to create custom grounds for c onnecting to
ice under test. When connecting to square pins, the P6516 has
the dev an adapter that attaches to the probe head extending the probe ground ush with the probe tip so you can attach to a header. The P6516 offers outstanding electrical characteristics, applying only 3 pF of loading.
6 www.tektronix.com
gonaspecific OUT Token packet on a USB full-speed serial bus. The yellow
Triggerin waveform i packet con Stop.
s the D+ and the blue waveform is the D–. A bus waveform provides decoded
tent including Start, Sync, PID, Address, End Point, CRC, Data values, and
Serial Triggering and Analysis (Optional)
On a serial bus, a single signal often includes address, control, data, and clock information. This can make isolating events of interest difcult. The MSO/DPO4000 Series offers a robust set of tools for debugging serial buses with automatic trigger, decode, and search for I LIN, FlexRay, RS-232/422/485/UART, and I
2
S/LJ/RJ/TDM.
Serial Triggering
Trigger on packet content such as start of packet, specic addresses, specic data content, unique identiers, etc. on popular serial interfaces
2
such as I
2
I
C, SPI, USB, CAN, LIN, FlexRay, RS-232/422/485/UART, and
S/LJ/RJ/TDM.
Bus Display
s a higher-level, combined view of the individual signals (clock, data,
Provide chip enable, etc.) that make up your bus, making it easy to identify where packets begin and end and identifying subpacket components such as address, data, identier, CRC, etc.
Bus Decoding
Tired of having to visually inspect the waveform to count clocks, determine if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
2
C, SPI, USB, CAN,
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
Event table showing decoded Identier, DLC, DATA, and CRC for every CAN packet in alongacquisition.
value? Let the oscilloscope do it for you! Once you’ve set up a bus, the MSO/DPO4000 Series will decode each packet on the bus, and display the value in hex, binary, d ecimal (USB, LIN, and FlexRay only), signed decimal
2
(I
S/LJ/RJ/TDM only), o r ASCII (USB and RS-232/422/485/UART only) in
the bus waveform.
Event Table
In addition to seeing decoded packet data on the bus waveform itself, you can view all captured packets in a tabular view much like you would see in a software listing. Packets are time stamped and listed consecutively with columns for each component (Address, Data, etc.).
Search
Serial triggering is very useful for isolating the event of interest, but once you’ve captured it and need to analyze the surrounding data, what do you do? In the past, users had to manually scroll through the waveform counting and converting bits and looking for what caused the event. With the MSO/DPO4000 Series, you can have the oscilloscope automatically
through the acquired data for user-dened criteria including serial
search packet content. Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Previous ()and Next () buttons on the front panel.
www.tektronix.com 7
Data Sheet
Safe opera accurate a
ting area measurement. Automated power measurements enable quick and
nalysis of common power parameters.
Power Analysis (Optional)
Ever increasing consumer demand for longer battery-life devices and for green solutions that consume less power require power-supply designers to characterize and minimize switching losses to improve efciency. In addition, the supply’s power levels, output purity, and harmonic feedback into the power line must be characterized to comply with national and
l power quality standards. Historically, making these and many
regiona other power measurements on an oscilloscope has been a long, manual, and tedious process. The MSO/DPO4000 Series optional power analysis tools greatly simplify these tasks, enabling quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (di/dt, dv/dt). Completely integrated into
lloscope, the power analysis tools provide automated, repeatable
the osci power measurements with a touch of a button; no external PC or complex software setup is required.
Viewing an ability to
NTSC video signal. Notice the intensity-graded view provided by the DPO’s
represent time, amplitude, and distribution of amplitude over time.
Video Design and Development
Many video engineers have remained loyal to analog oscilloscopes, believing the intensity gradations on an analog display are the only way to see certain video waveform details. The MSO/DPO4 000 Series fast waveform capture rate, coupled with its intensity-graded view of the signal, provides the same information-rich display as an analog oscilloscope, but with much
Standard features such as IRE and mV graticules, holdoff by elds, video polarity MSO/DPO4000 Series the easiest to use oscilloscope on the market for video applications. And with up to a 1 GHz bandwidth and four analog inputs, the MSO/DPO4000 Series provides ample performance for analog and digital video use.
The MSO/DPO4000 Series video functionality is further extended with the optional DPO4VID video application module. DPO4VID provides the industry’s most complete suite of HDTV and custom (nonstandard) video trigger
more detail and all the benets of digital scopes.
, and an Autoset s mart enough to detect video signals, make the
s.
8 www.tektronix.com
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
The MSO/DP display sh A USB host p settings,
O4000 is designed to make your work easier. The large, high-resolution
ows intricate signal details. Dedicated front-panel controls simplify operation.
ort on the front panel allows you to easily transfer screenshots, instrument
and waveform data to a USB thumb drive.
Designed to Ma ke Your Work Easier
Large, High-resolution Display
The MSO/DPO4000 Series features a 10.4 inch (264 mm) XGA color display for seeing intricate signal details.
Dedicated Front-panel Controls
Per-channel vertical controls provide simple and intuitive operation. No longer do you need to share one set of vertical controls across all four channels.
Connectivity
A USB host port on the front panel enables easy transfer of screenshots, instrument settings, and waveform data to a USB thumb drive. The rear panel contains two additional USB host ports and a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB
rd. The USB device port can also be used to print directly to a
keyboa PictBridge easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector.
Compact Form Factor
A compact, portable form factor allows the MSO/DPO4000 Series to be easily moved between labs and, with a depth of just 5.4 inches (137 mm), it saves you valuable space on your test bench.
®
-compatible printer. An integrated 10/100 Ethernet port enables
The MSO/DPO4000 Series’ compact form factor frees up valuable space on your bench or desktop.
TekVPI probe interface simplies connecting your probes to the oscilloscope.
TekVPI®Probe Interface
The TekVPI probe interface sets the standard for ease of use in probing. TekVPI probes feature status indicators and controls, as well as a probe menu button right on th e comp box itself. This button brings up a probe menu on
the oscilloscope display with all relevant settings and controls for the probe. The TekVPI interface enables direct attachment of current prob es without requiring a separate power supply. TekVPI probes can be controlled remotely through USB, GPI B, or Ethernet, enabling more versatile solutions in ATE environments.
www.tektronix.com 9
Data Sheet
W SignalExpress™ Tektronix Edition is a fully interactive measurement
NI LabVIE
ion and analysis software developed jointly with National Instruments and
acquisit
d for the MSO/DPO Series.
optimize
Extended Analysis
Acquiring data and measurements from the MSO/DPO4000 Series is as simple as connecting a USB cable from the o s cilloscope to your PC. Key software applications - NI LabVIEW SignalExpress™ Tektronix Edition LE, OpenChoice included standard with each oscilloscope to enable fast and easy direct communi
®
Desktop, and Microsoft Excel and Word toolbars - are
cation with your Windows PC.
OpenChoice®Desktop software enables seamless connection between the oscilloscope and your PC.
NI LabVIEW SignalExpress Tektronix Edition LE enables you to insta ntly
generate, analyze, compare, import, and save measurement data
acquire, and signals using an intuitive drag-and-drop user interface that does not require any programming. The optional Professional Version offers over 200 built-in functions that provide additional signal processing, advanced analysis, sweeping, limit testing, and user-dened step capabilities.
For simple tasks, the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB or LAN for transferring settings, waveforms, and screen images.
10 www.tektronix.com
Characteristics
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
Vertical Syst
Characteristic DPO4034
Input Channels Analog Bandwidth (–3 dB) 5 mV/div -
em Analog Channels
MSO4034
DPO4054 MSO4054
DPO4104 MSO4104
444
350 MHz 500 MHz
1GHz
1V/div Calculated Rise Time 5 mV/div (typical)
1 ns 700 ps 350 ps Hardware Bandwidth Limits 20 MHz or 250 MHz Input Coupling AC, DC, GND Input Impedance
1MΩ ±1%, 50 Ω ±1% Input Sensitivity, 1 M 1mV/divto10V/div Input Sensitivity, 50 1mV/divto1V/div Vertical Resolution Max Input Voltage, 1 M Max Input Voltage, 50
8 bits (11 bits with Hi Res)
250 V
with peaks ±400 V
RMS
5V
with peaks < ±20 V
RMS
DC Gain Accuracy ±1.5% with offset set to 0 V Channel-to-Channel Isolation 100:1 at 100 MHz and 30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings
Offset Range
Range
to 50 mV/div
1mV/div
div to
50.5 mV/
div
99.5 mV/ 100 mV/div to 500 mV/div
505 mV/div to 995 mV/div 1V/divto5V/div
5.05 V/div to 10 V/div
1M 50 Ω,75
±1 V ±1 V
±0.5 V ±0.5 V
±10V ±10V
±5 V ±5 V
±100 V ±5 V
±50 V NA
Horizontal System Analog Channels
Characteristic DPO4034
Maximum Sample
MSO4034
2.5 GS/s 2.5 GS/s 5 GS/s
DPO4054 MSO4054
Rate (All channels) Maximum
10M points Record Length (All channels)
Maximum Duration
4ms 4ms 2ms at Highest Sample Rate (All channels)
DPO4104 MSO4104
Time Base Range 1 ns to 1,000 s 400 ps to 1,000 s
Vertical System Digital Channels
Characteristic All MSO4000 Models
Input Channels 16 Digital (D15 - D0) Thresholds Per-channel Thresholds Threshold Selections TTL, CMOS, ECL, PECL, User Dened User-dened Threshold
+5 to –2 V
Time Base Delay Time Range
Channel-to-Channel Deskew Range
Time Base Accuracy
–10 divisions to 5000 s
0ns
±10
±5 ppm over any 1 ms interval
Range Maximum Input Voltage ±15 V Threshold Accuracy Input Dynamic Range 6 V Minimum Voltage Swing Input Impedance
±(100 mV + 3% of threshold setting)
p-p
500 mV 20 k
Probe Loading 3 pF Vertical Resolution 1 bit
centered around the threshold
Horizontal System Digital Channels
Characteristic All MSO4000 Models
Maximum Sample Rate
500 MS/s (2 ns resolution)
(Main) Maximum Record Length
10M points
(Main) Maximum Sample Rate
16.5 GS/s (60.6 ps resolution)
(MagniVu) Maximum Record Length
10k points centered around the trigger
(MagniVu) Minimum Detectable
1.5 ns
Pulse Width Channel-to-Channel
500 ps typical
Skew
www.tektronix.com 11
Data Sheet
Trigger System
Characteristi
Main Trigger Modes
c
Description
Auto, Normal, and Single
Trigger Coupling DC, AC, HF reject (attenuates >50 kHz), LF
reject (attenuates <50 kHz), noise reject (reduces sensitivity)
Trigger Holdoff
20nsto8s
Range
Trigger Sensitivity
Characteristi
c
Description
Internal DC Coupled 0.4 div from DC to 50 MHz, increasing to 1 div at
rated bandwidth
External (Auxiliary Input)
200 mV from DC to 50 MHz increasing to 500 mV at 250 MHz
Trigger Level Range
Characteristic Description
Any Channel ±8 divisions from center of screen
External
±8 V
(Auxiliary Input)
Trigger Modes
Mode Description
Edge
Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject Sequence (B-trigger) Trigger Delay by Time – 4 ns to 8 s. Or Trigger Delay by Events – 1 to 9,999,999 events Pulse Width Runt Logic
Trigger on width of positive or negative pulses that are >, <, =, or aspecified period of time
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the rst again
Trigger when any logical pattern of channels goes false or stays true for specied period of time. Any input can be used as a clock to look for the
pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specied for all analog and digital input channels dened as High, Low, or Don’t Care Setup and Rise/Fa
Hold
ll Time Video Extended Video
(Optional)
n violations of both setup time and hold time between clock and data present on any of the input channels
Trigger o
on pulse edge rates that are faster or slower than specied. Slope may be positive, negative, or either
Trigger
on all lines, odd, even, or all elds on NTSC, PAL, and SECAM video signals
Trigger
on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50,
Trigger
0, and custom bi-level and tri-level sync video standards
1080p/6 I2C (Optional) Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s SPI (Optional) Trigger on SS, MOSI, MISO, or MOSI and MISO on SPI buses up to 10.0 Mb/s USB (Optional) Low Speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger – Any token type, SOF, OUT, IN, SETUP; A ddress can be specied for Any Token, OUT, IN, and SETUP token types. Address can be further specied to trigger on ,<,=,>,≥, ≠ a particular value, or inside or outside of a range. Frame number can be specied for SOF token using binary, hex, unsigned decimal and don’t care digits. Data packet trigger – Any data type, DATA0, DATA1; Data can be further specied to trigger on ,<,=,>,≥, ≠ a particular data value, or inside or outside of a range. Handshake packet trigger – Any handshake type, ACK, NAK, STALL. Special packet trigger – Any special type, Reserved.
Error trigger – PID Check, CRC5 or CRC16, Bit Stufng. Full Speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error.
Token packet trigger – Any token type, SOF, OUT, IN, SETUP; A ddress can be specied for Any Token, OUT, IN, and SETUP token types. Address
can be further specied to trigger on ,<,=,>,≥, ≠ a particular value, or inside or outside of a range. Frame number can be specied for
SOF token using binary, hex, unsigned decimal and don’t care digits.
Data packet trigger – Any data type, DATA0, DATA1; Data can be further specied to trigger on ,<,=,>,≥, ≠ a particular data value, or inside
or outside of a range.
Handshake packet trigger – Any handshake type, ACK, NAK, STALL.
Special packet trigger – Any special type, PRE, Reserved.
Error trigger – PID Check, CRC5 or CRC16, Bit Stufng. High Speed: Trigger on edge. High Speed support only available on MSO4104 and DPO4104 models.
N (Optional)
CA
igger on Start of Frame, Frame Type (data, remote, error, overload), Identier (standard or extended), Data, Identier and Data, End of Frame,
Tr
ssing ACK, or Bit Stufng Error on CAN signals up to 1 Mb/s. Data can be further specied to trigger on ,<,=,>,,oraspecific data value.
Mi
ser-adjustable sample point is set to 50% by default
U
LIN (Optional) Trigger on Sync, Identier, Data, Identier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors up to 1 Mb/s (by
LIN denition, 20 kb/s)
FlexRay (Optional) Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identier, Cycle Count, Complete Header Field, Data, Identier and
Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors
RS-232/422/485/UART
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up to 10 Mb/s
(Optional) I2S/LJ/RJ/TDM
(Optional)
Trigger on Word Select, Frame Sync, or Data. Data can be further specied to trigger on ,<,=,>,≥, ≠ aspecific data value, or inside or outside of a range Maximum data rate for I
2
S/LJ/RJ is 12.5 Mb/s
Maximum data rate for TDM is 25 Mb/s
Parallel (Available on
Trigger on a parallel bus data value. Parallel bus can be from 1 to 16 bits in size. Binary and Hex radices are supported
MSO models only)
12 www.tektronix.com
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
Acquisition Modes
Mode Description
Sample
Peak Detect
Acquire sampl
Captures glitches as narrow as 2 ns at all sweep
ed values
speeds
Averaging
Envelope
From 2 to 512 waveforms included in average
Min-max envelope reecting Peak Detect data over multiple acquisitions
Hi Res Real-time
and increa
Roll
Scrolls waveforms right to left across the screen at
boxcar averaging reduces random noise
ses vertical resolution
sweep speeds slower than or equal to 40 ms/div
Waveform Measurements
Measurement Description
Cursors Waveform and Screen
Automatic Measurements
29, of which up to four can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak-to-Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area
Measurement
Mean, Min, Max, Standard Deviation
Statistics
Reference Levels User-denable reference levels for automatic
measurements can be specied in either percent or units
Gating Isolate the specic occurrence within an acquisition
to take measurements on, using either the screen, or waveform cursors
Waveform Histogram A waveform histogram provides an array of data
values representing the total number of hits inside of a user-denedregionofthedisplay. A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be measured. Sources – Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math Types – Vertical, Horizontal
Waveform Histogram Measurements
Waveform Count, Hits in Box, Pea k Hits, Median, Max, Min, Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3
Power Measurements (Optional)
Measurement Description
Power Quality Measurements
Measurements
Harmonics
V
RMS,VCrest Factor
Power, Appare Factor, P hase
Power Loss: T
Energy Loss: T
,Frequency,I nt Power, Reactive Power, Power
RMS,ICrest Factor
Angle
, Conduction, TotalSwitching Loss
on,Toff
, Conduction, Total
on,Toff
THD-F, THD-R, RMS measurements
Graphical
and table displays of harmonics
,True
Test to IEC61000-3-2 Class A and MIL-STD-1399
Ripple Measurements
Modulation Analysis
V
and I
ripple
ripple
Graphical display of +Pulse Width, –Pulse Width, Period, Frequency, +Duty Cycle, and –Duty Cycle modulation types
Safe Operating Area Graphical display and mask testing of switching
device safe operatingareameasurements
dV/dt and dI/dt
Cursor measurements of slew rate
Measurements
Waveform Math
Characteristic Description
Arithmetic
Math Functions
FFT
Add, subtract, multiply, and divide waveforms
Integrate, Differentiate, FFT
Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris
Advanced Math
Dene extensive algebraic expressions including waveforms, reference waveforms, math functions (FFT, Intg, Diff, Log, Exp, Sqrt, Sine, Cosine, Tangent), scalars, up to two user-adjustable variables and results of parametric measurements (Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOverShoot, NegOverShoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area, CycleArea, and trend plots), e.g.,(Intg(Ch1 – Mean(Ch1)) × 1.414 × VAR1)
www.tektronix.com 13
Data Sheet
Software
Software
NI LabVIEW SignalExpress Tektronix Edition LE
Description
A fully interactive measurement software environment optimized for the MSO/DPO4000 Series, enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard MSO/DPO4000 Series support for acquiring, controlling, viewing, and exporting your live signal data is permanently available through the software. The full version (SIGEXPTE) adds additional signal processing, advanced analysis, mixed signal, sweeping, limit testing, and user-dened step capabilities and is available for a 30-day trial period standard with each instrument.
OpenChoice
®
Desktop Enables fast and easy communication between a
Windows PC and the MSO/DPO4000 Series, using USB or LAN. Transfer and save settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis.
IVI Driver Provides a standard instrument programming
interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET and MATLAB.
eScope Enables control of the MSO/DPO4000 Series over a
network connection through a standard web browser. Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser.
Display Charact eristics
Characteristic
Display Type Display Resolution
Description
10.4 in. (264 mm) liquid-crystal TFT color display 1,024 horizontal × 768 vertical pixels (XGA)
Waveform Styles Vectors, Dots, Variable Persistence, Innite
Persistence
Graticules Full, Grid, Cross Hair, Frame, IRE, and mV Format
YT and simultaneous XY/YT
Waveform Capture Rate >50,000 wfm/s
Input/Output Ports
Port Description
CompactFlash Drive Front-panel access (Type 1) USB 2.0 Full-speed Host
Port
Supports USB mass storage devices, printers and keyboard. Two ports available on rear panel and one on front panel
USB 2.0 High-speed Device Port
Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB with a TEK-USB-488, and direct printing to all PictBridge-compatible printers
LAN Port
RJ-45 connector, supports 10/100Base-T
XGA Video Port DB-15 female connector, connect to show the
oscilloscope display on an external monitor or projector
Auxiliary Input
Probe Compensator Output
Front-panel BNC connector. Input Impedance 1 MΩ. Max input 250 V
with peaks ±400 V
RMS
Front-panel pins Amplitude: 2.5 V Frequency: 1 kHz
Trigger Out Rear-panel BNC connector, provides a positive polarity
pulse when the oscilloscope triggers
Kensington Lock Rear-panel security slot connects to standard
Kensington lock
Power Source
Characteristic
Description
Power Source Voltage 100 to 240 V ±10% Power Source Frequency 47 to 66 Hz (90 to 264 V)
360 to 440 Hz (100 to 132 V)
Power Consumption
250 W maximum
Physical Characteristics
Dimensions
mm
in.
Height 229 9.0 Width 439 17.3 Depth 137 5.4
Weight kg lb.
Net Shipping Rackmount Conguration
5
9.5 22 5U
11
Cooling Clearance 2 in. (51 mm) required on left side and rear
of instrument
Environmental
Characteristic
Description
Temperature
ng
Operati Nonoperating
0ºCto+5 –20 ºC t
0ºC
o+60ºC
Humidity
ing
Operat
Nonoperating
0 ºC to 50 ºC, 10% to 60% Relative Humidity
High: 4
C to 40 ºC, 10% to 90% Relative Humidity
Low: 0 º High: 40 ºC to 60 ºC, 5% to 60% Relative Humidity
Low: 0 ºC to 40 ºC, 5% to 90% Relative Humidity
Altitude
ating
Oper Nonoperating
0 meters (9,843 feet)
3,00
000 meters (39,370 feet)
12,
Random Vibration
rating
Ope
Nonoperating
1G
0.3 3ax
2.46 G 3 axes, 30 minutes total
from 5 to 500 Hz, 10 minutes each axis,
RMS
es, 30 minutes total
from 5 to 500 Hz, 10 minutes each axis,
RMS
Regulatory
Electromagnetic
89/336/EEC
Compatibility Safety UL61010-1, Second Edition; CSA61010-1 Second
Edition, EN61010-1:2001; IEC 61010-1:2001
14 www.tektronix.com
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
Ordering Information
MSO/DPO4000 Family
Model Description
DPO4000 Models
DPO4034 350 MHz, 2.5 GS/s, 10M record length,
DPO4054 500 MHz, 2.5 GS/s, 10M record length,
DPO4104 1 GHz, 5 GS/s, 10M record length,
MSO4000 Models
MSO4034 350 MHz, 2.5 GS/s, 10M record length,
MSO4054 500 MHz, 2.5 GS/s, 10M record length,
MSO4104 1 GHz, 5 GS/s, 10M record length,
All Models Include: One P6139A 500 MHz, 10x Passive Probe per Analog Channel, Front Cover (200-4908-xx), User Manual (071-2121-xx), Documentation CD (063-4022-xx), OpenChoice Tektronix Edition LE Software, Calibration certicates document measurement traceability to National Metrology Institute(s) – the Quality System this product is manufactured in is ISO9001 registered, power cord, accessory bag (016-1967-xx) and a three-year warranty. Please specify power plug and manual version when ordering.
MSO Models also Include: One P6516 16-channel logic probe and a logic probe accessory kit (020-2662-xx).
4-channel digital phosphor oscilloscope
4-channel digital phosphor oscilloscope
4-channel digital phosphor oscilloscope
4+16 channel mixed signal oscilloscope
4+16 channel mixed signal oscilloscope
4+16 channel mixed signal oscilloscope
®
Desktop Software, NI LabVIEW SignalExpress™
Application Modules
Module Description
DPO4AUDIO Audio Serial Triggering and Analysis Module. Enables
triggering on packet level information on I
2
S, LJ, RJ, and TDM audio buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information. Probing – I
2
S, LJ, RJ, TDM: Single ended.
DPO4AUTO Automotive Serial Triggering and Analysis Module.
Enables triggering on packet level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information. Probing – LIN: Single ended; CAN: S ingle ended or differential.
DPO4AUTOMAX Extended Automotive Serial Triggering and Analysis
Module. Enables triggering on packet level information on CAN, LIN, and FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time stamp information, and eye diagram analysis software. Probing – LIN: Single ended; CAN, FlexRay: Single ended or differential.
DPO4COMP Computer Serial Triggering and Analysis M odule.
Enables triggering on packet level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information. Probing – RS-232/422/485/UART: Single ended.
DPO4EMBD Embedded Serial Triggering and Analysis Module.
Enables triggering on packet level information on I
2
and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information. Probing – I
2
C, SPI: Single ended.
DPO4USB USB Serial Triggering and Analysis Module. Enables
triggering on packet level content for Low-speed and Full-speed USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time stamp information for Low-speed, Full-speed, and High-speed USB serial buses. Probing – Low Speed, Full Speed: Single ended or differential; High Speed: Differential. USB High Speed supported only on MSO4104 and DPO4104 models.
DPO4PWR
Power Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt).
DPO4VID HDTV and Custom (nonstandard) Video Triggering
Module.
C
www.tektronix.com 15
Data Sheet
Instrument Options
Power Plug Options
Option
Opt. A0 Opt. A1 Opt. A2 Opt. A3 Opt. A5 Switzerland Opt. A6 Opt. A10 China Opt. A11 Opt. A99 No power cord or AC adapter
Language Options*
Option
Opt. L0 Opt. L1 Opt. L2 Opt. L3 German manual Opt. L4 Spanish manual Opt. L5 Opt. L6 Opt. L7 Simplied Chinese manual Opt. L8 Traditional Chinese manual Opt. L9 Opt. L10 Opt. L99
*1Language options include a translated front-panel overlay for the selected language(s).
Service
Option
Options*
Opt. C3 Calibration Service 3 years Opt. C5 Calibration Service 5 years Opt. CA1 Provides a single calibration event, or coverage for the
Opt. D1 Calibration Data Report Opt. D3 Calibration Data Report 3 years (with Opt. C3) Opt. D5 Calibratio n Data Report 5 Years (with Opt. C5) Opt. R5 Repair Service 5 years (including warranty)
*2Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the
datasheet of each probe and accessory model for its unique warranty and calibration terms.
Description
North America Universal Euro United Kingdom Australia
Japan
India
1
Description
English manual French manual Italian manual
Japanese manual Portuguese manual
Korean manual Russian manual No manual
2
Description
designated calibration interval, whichever comes rst.
Recommended Probes*
Probe Description
TAP 1500 TAP1500X2
4
®
1.5 GHz TekVPI
active voltage probe
Bundle of two 1.5 GHz Active Probes, single ended with TekVPI Interface; Certicate of traceable calibration standard
TDP0500 TDP1000
500 MHz TekVPI 42 V differential probe 1 GHz TekVPI 42 V differential probe
TCP0030 120 MHz TekVPI 30 Ampere AC/DC current probe TCP0150 20 MHz TekVPI 150 Ampere AC/DC current probe TCPA300/400* P5200 P5205* P5210*
3
Current measurement systems amplier
1.3 kV, 25 MHz high-voltage differential probe
3
3
1.3 kV, 100 MHz high-voltage differential probe
5.6 kV, 50 MHz high-voltage differential probe
P5100 2.5 kV, 100x high-voltage passive probe ADA400A*
3
100x, 10x, 1x, 0.1x high-gain differential amplier
NEX-HD2HEADER Mictor connector breakout to 0.1 in. header pins DPO4PWRBND Power
Solution Bundle
Includes P5205 and TDP0500 differential voltage probes, TCP0030 current probe, TPA-BNC adapter, deskew pulse generator (TEK-DPG), deskew xture, and power analysis module (DPO4PWR) in a hard-sided carrying case. Bundle discount reected in price
*3Requires TekVPI®-to-TekProbe BNC adapter (TPA-BNC).
4
For a full selection of probes please visit the interactive probe selector tool at www.tek.com/probes.
*
Recommended Acces sories
Accessory Description
071-1844-xx
Service Manual (English only)
SIGEXPTE NI LabVIEW SignalExpress™ Tektronix Edition
Software (Full Version)
FPGAView-xx MSO Support for Altera and Xilinx FPGAs TPA-BNC TekVPI-to-TekProbe BNC Adapter TEK-USB-488 GPIB-to-USB Adapter TLAHRA with (2)
196-3476-xx 119-6827-xx
4000
ACD
EK4321
HCT
High-impedance Adapter and Leadsets for P6516 MSO Probe
pactFlash-to-USB Memory Card Reader
Com
t Transit Case
Sof
d Transit Case (Requires ACD4000)
Har
RM4000 Rackmount Kit TEK
-DPG
kew Pulse Generator
Des
067-1686-xx Deskew Fixture
Warranty
Three-year warranty covering all parts and labor, excluding probes.
16 www.tektronix.com
Product(s) are manufactured in ISO registered facilities.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
www.tektronix.com 17
Data Sheet
18 www.tektronix.com
Mixed Signal Oscilloscopes — MSO4000 Series, DPO4000 Series
www.tektronix.com 19
Data Sheet
Contact Tektronix:
ASEAN / Australa
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Central East Eu
Mexico, Central/South America & Caribbean 52 (55) 54247900
rope, Ukraine, and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Luxembourg +44 (0) 1344 392400
Middle East,
For other areas contact Tektronix, Inc at: 1 (503) 627-7111
Asia, and North Africa +41 52 675 3777
The Netherlands 090 02 021797
People’s Rep
United Kingdom & Ireland +44 (0) 1344 392400
ublic of China 86 (10) 6235 1230
Republic of
sia (65) 6356 3900
Austria +41 52 675 3777
Belgium 07 81 601
Brazil +55 (11) 3759-7627
Canada 1 (800) 661-5625
Denmark +4580881401
Finland +41526
France +33(0)169868181
Germany +49 (221) 94 77 400
Hong Kong (852
India (91) 80-42922600
Italy +39 (02) 25086 1
Japan 81 (3) 67
Poland +41 52 675 3777
Portugal 80 08 12370
Korea 82 (2) 6917-5000
Russia & CIS +7 (495) 7484900
South Africa +27 11 206 8360
Spain (+34)
Sweden 020 08 80371
Switzerland +41 52 675 3777
Tai wan 886 (
USA 1 (800) 426-2200
75 3777
) 2585-6688
14-3010
Norway 800 16098
901 988 054
2) 2722-9622
Updated 5 August 2009
66
www.tektronix.com
For Further Information. Tektronix ma intains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com
t © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
Copyrigh
d pending. Information in this publication supersedes that in all previously published material.
issued an
tion and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Specica
x, Inc. All o ther trade names referenced are the service marks, trademarks, or registered trademarks
Tek tr on i
espective companies.
of their r
28 Oct 2009 3GW-20156-7
Loading...