Atec MS-50 User Manual

M
M
Automated High Speed Production Console Helium Leak Detector
Quickly and accurately detects leaks for a broad range of applications
Dual pump system – dedicated Dry Foreline and Dry Roughing Pumps
Built-in diagnostics for trouble­free maintenance
Simple one-button power up has system ready to test in less than 3-minutes
Fully automatic startup, tuning and calibration
High inlet pressure of 7.5 Torr provides fast time to test
Three flow modes provide flexibility and maximum productivity for application­specific leak testing
Resolution of 14 at mass 4 is twice the industry average
The only production leak detector with a full screen interactive flat panel LCD display
www.vicleakdetection.com
S
S
5
5
0
0
S
S
e
e
rii
r
e
e
s
The MS-50 is available in various
configurations designed to meet
your specific leak testing
requirements.
Vacuum Instrument Corporation
2099 Ninth Avenue • Ronkonkoma, NY 11779 • T 631 737 0900 • F 631 737 1541 • sales@vicleakdetection.com
VIC Leak Detection is a registered trademark and the VIC Symbol and the MS-(series) are trademarks of Vacuum Instrument Corporation. © 2008 Vacuum Instrument Corporation.
MS50 PERFORMANCE SPECIFICATIONS
Characteristics
Sensitivity, vacuum *
Sensitivity, sniffing
Leak Measurement Range
Leak Ranging
Start-up Time
Response Time *
Resolution *
Gross Test, Time (with UFT Option)
Fine Test, Time (with UFT Option)
Mass Spectrometer Tube
Auto-tuning
Auto-calibration
Auto-zeroing
Reject Set-point
Built-in Calibrated Leak
NIST Traceable
Temperature Compensated
Scan / Descan
Filaments
Max Operating Pressure
Display
Units
I/O
Printer Port
RS-232C
Software
Vacuum System
Vacuum Mode
Roughing Pump
Foreline Pump
High Vacuum Pump
Vacuum Gauging
Cold Trap
Physical
Dimensions (W x H x D)
Test Cup, UFT Option (∅ x D)
Test Port Connection
Weight
Electrical
Power
Units
atm cc/sec
-
minutes
seconds
-
seconds
seconds
-
-
-
-
-
-
-
-
-
-
Torr
inches (cm)
-
-
-
-
-
-
cfm
-
liters/second
-
-
inches (cm)
inches (cm)
inches
lbs. (kg)
V/Hz/A
MS-50 MS-50 Dry MS-50 Dry HS
-11
3.0 x 10
3.0 x 10
3.0 x 10
-08
1.0 x 10
-11
to 10 3.0 x 10
Auto/Manual
<3
<2 direct, <2.5 reverse <2
14 at mass 4
3 (100 mTorr)
-10
10 (25 mTorr, 10
atm-cc/sec)
180° deflection, dual magnetic sector
Yes
Internal: Yes / External: Manual
Yes
Yes
-08
Yes; 10
range Yes; 10
Yes
Yes
Yes
2 Tungsten
7.5 fine; 100 gross 0.200
15 (38.1) LCD flat panel display
cc/second, mbar*l/second, Pa*M3/second
0~5V chart, parallel printer
Yes
Yes
50 programmable test recipes
Direct, reverse or combination Direct
16 direct drive 10 scroll pump
7 direct drive 5 dual stage diaphragm/molecular drag
61 turbo
Pirani: Test Port and Foreline / Ion: High Vacuum
N/A N/A Optional
25.75 x 30.625 x 35.25 (65.40 x 77.79 x 89.54)
4.5 x 1.0 (11.4 x 2.5)
1.125
475 (215.45)
115/50-60/30; 230-240/50-60/15; 100/50-60/30
-12
-12
to 1.0 x 10-5
-09
range
Vacuum Instrument Corporation
2099 Ninth Avenue • Ronkonkoma NY 11779 • Tel 631 737 0900 • Fax 631 737 1541 www.vicleakdetection.com email sales@vicleakdetection.com
* Performance determined in accordance with American Vacuum Society Standards; Specifications subject to change without notice. ©2008 Vacuum Instrument Corporation; ®VIC Leak Detection is a registered trademark and the VIC symbol and the MS-(series) are trademarks of Vacuum Instrument Corporation.
REVF090211
Loading...