Atec MS1000, MS1200, MS1300D, MS1400 User Manual

ACTERNA TEST & MEASUREMENT SOLUTIONS
Signal Level Meters
MS-1000, MS-1200D, MS-1300D, MS-1400
Key Features
System bandwidth expansion and digital service deployment have placed greater demands on CATV installers. Today’s installers require a Signal Level Meter (SLM) that combines advanced measurement capability with the ruggedness needed for everyday field use. The family of JDSU Signal Level Meters offers comprehensive,reliable measurement performance to meet the needs of installers deploying services at every phase of the network cycle.
• Easy-to-use, icon-based interface for all instruments and multilingual firmware options available
• Efficient and automated testing, plus convenient proof-of­performance compliance testing with results viewable immediately on-screen or tests scheduled over time for printing later
• Fast, easy location of forward and reverse ingress and interference with an advanced ingress spectrum scan
• Complete digital measurement solution for DTV and cable modem signals including digiCheck™ average power measurement with auto limit check
• Extended battery life of the MS-1400 – approximately five hours, and faster charging times improve productivity
WEBSITE: www.jdsu.com
JDSU Signal Level Meters are designed to help installers perform their work effectively, faster, and more easily, to improve productivity and reduce costs. The same easy-to-use, icon-based interface for all instruments in the family, minimizes training requirements and downtime. All instruments are light, portable, durable and water-resistant. They are designed to meet the tough requirements of field use and like all JDSU instruments, they are built to last and to deliver sustained value.
2
SIGNAL LEVEL METERS
The MS-1000 is ideal for installers responsible for activating broadcast CATV service. The six-channel scan and installation check provide the essential capability to ensure high­quality CATV installation.
The new digital SLMs, MS-1200D and MS-1300D, offer the advanced performance capability that digital installers need, at a cost that does not strain budgets. New standard features include digital average power measurement, with the patented digiCheck™ method and 5-890 MHz frequency range.
Additional standard features such as the reverse ingress scan of the MS-1300D, and customizable channel plans for the MS-1200D make JDSU Signal Level Meters the best priced performance field meters currently on the market.
The MS-1400 offers a complete set of analog and digital measurement capability, with the added benefits of forward ingress scan, an upgradeable platform, extended-life battery, and multilingual firmware options. The MS-1400 also can beupgraded to a JDSU CLI-1450 or CLI-1750 which adds more advanced capability including signal leakage detection.
Features MS-1000 MS-1200D MS-1300D MS-1400
Icon Driven User Interface • 6 Channel Scan • Installation Check • Configure by Channel or Frequency • Channel Video/Audio Level & Delta • FCC & CENELEC Limit Check • Tilt Mode ••• Cloning ––•• Copy Remote Channel Plan ••• Prints Current Data ••• All Channel Scan/Full Scan ••• Ingress Scan in Reverse Band ––•• Ingress Scan in Forward Band –––• Customized Channel Plans ••• Stores Measured Results/Screens ••• 24 Hour – Auto Test ••• Prints Stored Results ••• Downloads to StealthWare ––•• digiCheck™- Digital Measurement ••• Analog Limits ••• Digital Limits –––• Multilingual LCD Screen –––• Standard 45-550 MHz Frequency Range ––– Optional 45-890 MHz Frequency Range ––– Standard 5-890 MHz Frequency Range •••
Powerful features
Signal Level Meters are designed for the challenges of installing and main­taining the cable networks of today.
Features
Single channel display and
six-channel scan have PASS/FAIL indicators for quick performance
– Ingress Scan mode – allows users
to find forward and reverse ingress problems from the tap to the drop
– digiCheck™ digital signal measure-
ment measures DVB, digital TV, cable modem, Internet, and telephony on-cable services
Upgradeable
To MS-1000 MS-1200 MS-1300 MS-1200D MS-1300D MS-1400
MS-1200 N/A N/A N/A N/A N/A MS-1300 ––N/A N/A N/A N/A MS-1200D • MS-1300D • MS-1400 CLI-1450 CLI-1750
–––– – N/A –––– – –––– –
N/A N/A N/A N/A
N/A
3
SIGNAL LEVEL METERS
The results are displayed in a list indicating which parameters are out of tolerance.If all levels are within
will show in the far right column.If any
limits, a parameter is out of tolerance an X will be shown
Level measurement
All instruments provide a compre­hensive single-channel display and a multichannel display with pass/fail indicators. The multichannel display quickly and clearly indicates if all channels are being received at the subscriber’s drop at appropriate system design levels.
Pressing the cycle soft key provides more detail by bringing up a list of all channels. Passing channels
in the right hand column
have a
Installation check
Pressing key provides an installation status check, which allows technicians to verify that all levels are within user­defined limits. Up to four different limits can be configured: tap, ground block, subscriber drop, and custom. This feature can be used to determine if a subscriber connection meets cable network or government specifications.
Pressing the cycle soft key provides a detailed view of which specific error is on the specific channel
These results can be printed, (MS-1200D, MS-1300D, MS-1400) or downloaded to the PC for report generation using JSDSU StealthWare™ Data Analysis Software (MS-1300D, MS-1400).
The single channel display shows the video and audio carrier levels and the difference between levels. Compatible with dual sound and NICAM
The six-channel scan shows six different user-defined video carriers, with PASS/FAIL indicator for user­defined limit
The full scan display shows all user-defined video carriers.The unique limit check feature quickly checks the results against user-defined analog (MS-1200D, MS-1300D and MS-1400D) and digital limits (MS-1400)