MPP2000
Megger Pinpointer
Megger Pinpointer
n
 Universal pinpoint fault location system
n
 Ergonomic, rugged, weather resistant 
case
MPP2000
n
 Electromagnetic, acoustic and time delay 
fault location methods
n
 Displays magnetic and acoustic signal 
levels
n
 Displays relative distance and direction 
to the fault
n
 Large backlit LCD
n
 Background interference suppression 
using selectable filters
DESCRIPTION
The Megger Pinpointer model MPP2000 is specifically 
designed to accurately and quickly pinpoint faults in 
underground cable networks. Easy-to-access menus provide 
advanced users the flexibility and features they desire. 
The MPP2000 is housed in a lightweight, ergonomically 
designed, rugged case that is IP54 rated. The unit can 
be easily carried “hands free” using the adjustable neck 
strap. In addition, the instrument can be used with any 
manufacturer’s surge generator (thumper).
The MPP2000 is used to detect the acoustic and 
electromagnetic fields. Both fields are generated by the 
flashover at the point of fault, which has been generated by 
the HV impulse caused by a surge generator. Detection is 
via a lightweight ground microphone, which has a physical 
shield to reduce external wind noise. 
For easy interpretation, the receiver’s display shows clear, 
unambiguous readings. The user interface features standard 
directional and select arrow keys for easy navigation. 
For operator comfort, and for use when the operator is 
wearing a safety helmet, the MPP2000 is supplied with  
“behind-the-head” headphones. Active noise-cancelling 
headphones are available as an optional accessory. 
Additionally the unit has a built-in “auto mute,” eliminating 
all ambient noise, which is activated when the ground 
microphone is raised from the ground. 
The unit has an integral loudspeaker, the volume of which 
can be adjusted for user comfort via the touchpad controls. 
A single pushbutton “mutes” the output both on the 
headphones and loudspeaker simultaneously. 
The MPP2000 provides:
n
 Detection of the acoustic discharge (“thump”) and 
measurement of acoustic signal strength.
n 
Detection and indication of the electromagnetic signal 
strength.
n 
Measurement of time delay between acoustic and 
electromagnetic signals.
n 
Indication of the direction to fault.
n 
Calculated relative distance to fault.
APPLICATIONS
The MPP2000 pinpoints faults in underground power 
cables using acoustic, electromagnetic and time delay 
methods, enabling quick and accurate pinpoint location of 
underground cable faults.
The location of the buried cable is indicated by the 
intensity of the electromagnetic field produced by the HV 
pulses of a surge generator. The bargraph indicator of the 
MPP2000 shows a maximum intensity of the magnetic field 
directly above the cable, reducing as the operator moves 
away from the route of the cable. 
Accurate and fast fault locating is accomplished using the 
coincidence measurement of the acoustic signal, in time 
relation to the electromagnetic signal produced at the 
“flashover” or point of fault. 
The receiver’s display shows the acoustic signal strength 
and the time delay between the electromagnetic surge and 
acoustic event. 
When directly over the fault, the time difference is at a 
minimum and the acoustic level is at a maximum. This is 
especially useful when the cable is in a duct or pipe where 
the acoustic signal could mislead the operator.

Behind-the-head headphones fit 
comfortably even when worn 
with safety helmet.
FEATURES AND BENEFITS
n 
Lightweight receiver with durable weather-resistant 
enclosure.
n 
Comfortable neck strap allowing two-handed operation 
and “hands-free” carrying of the unit.
n 
Easy-to-read graphical display of acoustic and 
electromagnetic signal levels.
n 
Measures distance to cable fault by calculating 
electromagnetic surge/acoustic emission, providing fast, 
accurate fault pinpointing.
n 
Bargraph magnetic field strength indicator.
n 
Backlit LCD visible in direct sunlight.
n 
Behind-the-head headphones.
n 
A sturdy yet flexible wind guard insulates the ground 
microphone from ambient noises.
n 
Durable carrying case holds all components.
n 
Optional noise-cancelling headphones are available.
Megger Pinpointer
MPP2000
Noise Canceling Acoustic Filters
Digital: (3) HPF, (1) BPF, none
Acoustic Bands
120Hz to 1.8kHz 
Amplification Acoustic Channel
> 0 to 100 dB 
Magnetic Channel
> 0 to 100 dB
Display Range
00.0 ms to 99.9 msec
Overflow Display 
”OVFL” for distance values > 100 ms
Frequency Range
120 Hz to 1.8 kHz (acoustic)
Display
Large, easy-to-read 3.5” color LCD with backlight
Power
8 standard alkaline or replaceable lithium AA cell batteries
Battery Life
Alkaline, 24hours continuous : Lithium, 30hours continuous : 
>150hours intermittent (approx.)
Temperature Range 
Operating:  -4°F to 122°F (-20°C to 50°C) 
Storage:  -4°F to 149°F (-20°C to 65°C)
Environmental
Rated to IP54
Humidity
95% noncondensing
Dimensions 
8 L x 6.5 W x 3.25 H in. (203 L x 165 W x 83 H mm)
Weight
2.15 lb (.98 kg)
SPECIFICATIONS
Operating Mode 
Acoustic and electromagnetic pinpoint fault location — coincidence 
or time delay — pinpoint fault location — relative distance to fault 
— direction to fault indication 
Range 
0 to 99.9 ms
Resolution 
0.1 ms
Outputs
Loudspeaker 
1 x jack for headphones
Volume 
Adjustable for both headphone and loudspeaker
Acoustic Gain 
Manual
Electromagnetic Gain
Manual
UK 
Archcliffe Road, Dover 
CT17 9EN England 
T +44 (0) 1 304 502101  
F +44 (0) 1 304 207342 
UKsales@megger.com
UNITED STATES 
4271 Bronze Way 
Dallas, TX 75237-1019 USA 
T 1 800 723 2861 (USA only) 
T +1 214 333 3201  
F +1 214 331 7399 
USsales@megger.com
ORDERING INFORMATION
Item (Qty)  Cat. No.
MPP2000 Pinpointer 
Included Accessories
Ground microphone  1001-809
Behind-the-head headphones  90003-250
Carry strap  6220-780
MPP2000 (complete) Carry Case  2002-119
“AA” battery (8 required)  23415
Instruction manual MPP2000  81395
Optional Accessory
Noise-cancelling headphones  36162
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, College Station USA, 
Täby SWEDEN, Sydney AUSTRALIA, 
Ontario CANADA, Trappes FRANCE, 
Oberursel GERMANY, Mumbai INDIA, 
Johannesburg SOUTH AFRICA, Aargau 
SWITZERLAND, Chonburi THAILAND, 
and Dubai UAE 
ISO STATEMENT
Registered to ISO 9001:2000 Reg. No. Q 09250 
Registered to ISO 14001 Reg. No. EMS 61597
MPP2000_DS_US_V01 
www.megger.com
Megger is a registered trademark. 
Specifications subject to change 