MPP2000
Megger Pinpointer
Megger Pinpointer
n
Universal pinpoint fault location system
n
Ergonomic, rugged, weather resistant
case
MPP2000
n
Electromagnetic, acoustic and time delay
fault location methods
n
Displays magnetic and acoustic signal
levels
n
Displays relative distance and direction
to the fault
n
Large backlit LCD
n
Background interference suppression
using selectable filters
DESCRIPTION
The Megger Pinpointer model MPP2000 is specifically
designed to accurately and quickly pinpoint faults in
underground cable networks. Easy-to-access menus provide
advanced users the flexibility and features they desire.
The MPP2000 is housed in a lightweight, ergonomically
designed, rugged case that is IP54 rated. The unit can
be easily carried “hands free” using the adjustable neck
strap. In addition, the instrument can be used with any
manufacturer’s surge generator (thumper).
The MPP2000 is used to detect the acoustic and
electromagnetic fields. Both fields are generated by the
flashover at the point of fault, which has been generated by
the HV impulse caused by a surge generator. Detection is
via a lightweight ground microphone, which has a physical
shield to reduce external wind noise.
For easy interpretation, the receiver’s display shows clear,
unambiguous readings. The user interface features standard
directional and select arrow keys for easy navigation.
For operator comfort, and for use when the operator is
wearing a safety helmet, the MPP2000 is supplied with
“behind-the-head” headphones. Active noise-cancelling
headphones are available as an optional accessory.
Additionally the unit has a built-in “auto mute,” eliminating
all ambient noise, which is activated when the ground
microphone is raised from the ground.
The unit has an integral loudspeaker, the volume of which
can be adjusted for user comfort via the touchpad controls.
A single pushbutton “mutes” the output both on the
headphones and loudspeaker simultaneously.
The MPP2000 provides:
n
Detection of the acoustic discharge (“thump”) and
measurement of acoustic signal strength.
n
Detection and indication of the electromagnetic signal
strength.
n
Measurement of time delay between acoustic and
electromagnetic signals.
n
Indication of the direction to fault.
n
Calculated relative distance to fault.
APPLICATIONS
The MPP2000 pinpoints faults in underground power
cables using acoustic, electromagnetic and time delay
methods, enabling quick and accurate pinpoint location of
underground cable faults.
The location of the buried cable is indicated by the
intensity of the electromagnetic field produced by the HV
pulses of a surge generator. The bargraph indicator of the
MPP2000 shows a maximum intensity of the magnetic field
directly above the cable, reducing as the operator moves
away from the route of the cable.
Accurate and fast fault locating is accomplished using the
coincidence measurement of the acoustic signal, in time
relation to the electromagnetic signal produced at the
“flashover” or point of fault.
The receiver’s display shows the acoustic signal strength
and the time delay between the electromagnetic surge and
acoustic event.
When directly over the fault, the time difference is at a
minimum and the acoustic level is at a maximum. This is
especially useful when the cable is in a duct or pipe where
the acoustic signal could mislead the operator.
Behind-the-head headphones fit
comfortably even when worn
with safety helmet.
FEATURES AND BENEFITS
n
Lightweight receiver with durable weather-resistant
enclosure.
n
Comfortable neck strap allowing two-handed operation
and “hands-free” carrying of the unit.
n
Easy-to-read graphical display of acoustic and
electromagnetic signal levels.
n
Measures distance to cable fault by calculating
electromagnetic surge/acoustic emission, providing fast,
accurate fault pinpointing.
n
Bargraph magnetic field strength indicator.
n
Backlit LCD visible in direct sunlight.
n
Behind-the-head headphones.
n
A sturdy yet flexible wind guard insulates the ground
microphone from ambient noises.
n
Durable carrying case holds all components.
n
Optional noise-cancelling headphones are available.
Megger Pinpointer
MPP2000
Noise Canceling Acoustic Filters
Digital: (3) HPF, (1) BPF, none
Acoustic Bands
120Hz to 1.8kHz
Amplification Acoustic Channel
> 0 to 100 dB
Magnetic Channel
> 0 to 100 dB
Display Range
00.0 ms to 99.9 msec
Overflow Display
”OVFL” for distance values > 100 ms
Frequency Range
120 Hz to 1.8 kHz (acoustic)
Display
Large, easy-to-read 3.5” color LCD with backlight
Power
8 standard alkaline or replaceable lithium AA cell batteries
Battery Life
Alkaline, 24hours continuous : Lithium, 30hours continuous :
>150hours intermittent (approx.)
Temperature Range
Operating: -4°F to 122°F (-20°C to 50°C)
Storage: -4°F to 149°F (-20°C to 65°C)
Environmental
Rated to IP54
Humidity
95% noncondensing
Dimensions
8 L x 6.5 W x 3.25 H in. (203 L x 165 W x 83 H mm)
Weight
2.15 lb (.98 kg)
SPECIFICATIONS
Operating Mode
Acoustic and electromagnetic pinpoint fault location — coincidence
or time delay — pinpoint fault location — relative distance to fault
— direction to fault indication
Range
0 to 99.9 ms
Resolution
0.1 ms
Outputs
Loudspeaker
1 x jack for headphones
Volume
Adjustable for both headphone and loudspeaker
Acoustic Gain
Manual
Electromagnetic Gain
Manual
UK
Archcliffe Road, Dover
CT17 9EN England
T +44 (0) 1 304 502101
F +44 (0) 1 304 207342
UKsales@megger.com
UNITED STATES
4271 Bronze Way
Dallas, TX 75237-1019 USA
T 1 800 723 2861 (USA only)
T +1 214 333 3201
F +1 214 331 7399
USsales@megger.com
ORDERING INFORMATION
Item (Qty) Cat. No.
MPP2000 Pinpointer
Included Accessories
Ground microphone 1001-809
Behind-the-head headphones 90003-250
Carry strap 6220-780
MPP2000 (complete) Carry Case 2002-119
“AA” battery (8 required) 23415
Instruction manual MPP2000 81395
Optional Accessory
Noise-cancelling headphones 36162
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, College Station USA,
Täby SWEDEN, Sydney AUSTRALIA,
Ontario CANADA, Trappes FRANCE,
Oberursel GERMANY, Mumbai INDIA,
Johannesburg SOUTH AFRICA, Aargau
SWITZERLAND, Chonburi THAILAND,
and Dubai UAE
ISO STATEMENT
Registered to ISO 9001:2000 Reg. No. Q 09250
Registered to ISO 14001 Reg. No. EMS 61597
MPP2000_DS_US_V01
www.megger.com
Megger is a registered trademark.
Specifications subject to change
without notice.