Atec MFT1500 User Manual

MFT1500 Series
Combined Insulation, Loop & RCD Tester
MFT1500 Series
Combined Insulation, Loop & RCD Tester
Combined 16th Edition testing
Guaranteed non-tripping loop test range
Backlit display and selector ranges
Automatic RCD testing (MFT1552 &
MFT1553 only)
Bluetooth downloading (MFT1553 only)
Illuminated switch probe
Selectable touch voltage
Touch (fault) voltage and display
DESCRIPTION
The MFT1500 series multifunction tester has been revised to include some additional new features:
Called the MFT1500 series, they retain all the essential features necessary for testing domestic, commercial and industrial fixed wiring, and now include the following:
Selectable Fault (Touch) voltage 25 V or 50 V
Fault (Touch) voltage display
New Megger lead set included with all instruments
DC test functions for RCDs
All instruments test in accordance with International Standards and National Wiring Regulations including BS7671 (16th Edition wiring regulations) and European Standard EN61557.
In addition, the MFT1500 series also meets or exceeds the requirements of EN61010-1 Category III 480 V (max) phase­phase.
The MFT1500 is available in 4 options, the standard MFT1501/2 the MFT1502/2 which includes useful additional facilities such as backlit display and range switches, plus the unique Megger illuminated switched probe, the MFT1552 which has an automatic RCD test feature, and the MFT1553 which has Bluetooth downloading capability
The unique modern styling of the instruments allows it to be operated whilst stood on the floor, a ledge, hung around the neck with the supplied neck strap, or held in the hand.
Calibrated earth loop test lead
Calibration certificate
FEATURES
The MFT1500 series uses the patented Megger digital/ analogue arc display. The analogue arc provides an indication of fluctuating readings, while the digital readout providing the ability to record accurate results.
All test functions are selectable from the main panel, with no hidden ranges or functions to forget.
Special functions include:
VOLTAGE MEASUREMENT
AC/DC Volt meter provides a means of measuring the
supply voltage independently of any other test functions, eliminating the need to carry a separate multimeter. Automatic selection of AC or DC measurement up to 500 V a.c./d.c.
CONTINUITY TESTING
200 mA continuity from 0.01 Ω to 99.9 kΩ exceeds all
current requirements for testing final ring circuit conductors, and bonding of services.
Automatic continuity testing commences the moment
the test probes touch the circuit to be tested, allowing fast testing with both hands free.
Fast continuity buzzer is a fast buzzer tone, with no
delay on each test for the buzzer to sound, saving valuable operator time. This test includes a fast safety check for the presence of a voltage as the test probes are connected to the circuit.
MFT1500 Series
Combined Insulation, Loop & RCD Tester
Variable buzzer threshold controls the limit at which
the continuity buzzer stops sounding. Selected from 2 Ω to 100 Ω in 6 steps.
Lead null stores the test lead resistance and deducts this
value from the continuity result, even if the instrument is switched off. Thus reducing the chance of possible measurement errors.
Insulation testing:
Insulation test at 250 V, 500 V and 1000 V for testing
low voltage applications. A 1000 V warning is issued prior to performing the 1000 V insulation test.
Live circuit warning when performing insulation or
continuity measurements a live circuit warning is displayed and an audible warning sounded if connected to a circuit with a voltage greater than 25 V (15 V for continuity testing).
Safety lockout at voltages greater than 55 V during
continuity and insulation testing, the instrument automatically warns the operator and inhibits any testing, preventing accidental damage to the instrument and full protection to the operator.
The ‘Auto discharge’ facility safely discharges all
circuits after an insulation test, preventing accidental shock from a stored charge on a long cable during or after disconnection.
LOOP TESTING
Low current loop test is a 3 wire non-tripping
0.01 Ω loop test designed to prevent RCD tripping by using a sophisticated 15 mA loop test pioneered by Megger Limited. This NO-TRIP test ensures the RCD will not trip whilst performing a loop impedance test.
High current loop test at 25 A provides a fast loop test
where no RCD is fitted, or for Ze measurement on the incoming side of an RCD.
Supply voltage and polarity indication upon
connection to the mains supply the polarity and voltage are displayed to show correct wiring of the socket under test or test lead connections. This function also provides a warning of live voltages while continuity or insulation testing.
Phase-Phase Phase-Neutral and Phase-Earth Loop Tests
are possible. No danger of damage from accidental 3­phase connection.
Wide supply voltage; allows loop measurements from
55 V to 480 V. No damage if accidentally connected across phases.
Prospective short-circuit current (PSC) A dedicated
PSC range, using either the 25 A high current loop test or no-trip test, is provided for rapid measurement of Loop currents, both at the socket outlet and distribution board. The PSC ranges from 1 A to 19.9 kA with a resolution of 1 A, 10 A and 100 A depending on range. All the loop and PSC tests are auto-ranging.
RCD TESTING:
10 mA to 1000 mA RCD ranges. All standard RCDs
from 10 mA to 1000 mA are fully supported. All standard RCD test functions are available with both 0° and 180° phase angle at
RCD ramp test measures the RCD trip current. The
1/2I, I and 5I up to 300 mA.
ramp test displays the actual trip current on all RCD ranges instead of trip time. Ideal for identifying nuisance tripping RCDs. The current is stepped up from
1/2I to I in
200 ms steps.
Fault (Touch) voltage can now be set for either 25 V or
50 V depending on application.
Fault/touch voltage can also be displayed up to 100 V on
a selectable bargraph.
DC sensitive, RCD test option enables testing at 1/2I,
I and 5I.
GENERAL FEATURES:
Quick to pick up and use by using colour coded
ranges and no hidden functions the MFT1500 series takes minutes to learn how to use. Function buttons are colour matched to the test mode to ensure easy operation.
Visible and audible Safety warning features are
paramount with live circuit warning and protection circuitry. If live voltages exist on a circuit during insulation or continuity testing the voltage is displayed on the screen. If this voltage exceeds a safe level, the MFT1500 series inhibits further testing and a warning beeper sounds for extra safety.
Large easy-to-read LCD using the patented Megger
digital/analogue arc technology - combining high speed analogue clarity with digital stability. Making it easy to read even in low light level.
Economical with batteries by incorporates an auto
shut off facility that operates after 5 minutes of inactivity, reducing wasted battery consumption.
Innovative test lead connection has been developed
for the MFT1500 series. The unique shutter system allows only those combinations of test leads permitted for safe testing to be connected. Unsafe or unnecessary options cannot be connected.
Rubber over-moulded case. The ergonomic rubber
moulding provides a secure comfortable hold, whilst providing maximum protection with IP54 weather proof rating.
Calibration certificate
3 year warranty
MFT1502/2 Additional features
Illuminated switched probe shines a new light on testing.
A fully featured test probe allows for single-handed operation and test status indication. Probe features include:
Remote test button for single-handed testing in difficult
locations, the test button duplicates the instrument test
Loading...