Simplex Merlin Load Banks are the new standard for advanced design in Portable Load Banks spanning the capacity range of 100–400KW. The Merlin is a dual voltage (240/480v), fi ne load step resolution, fully instrumented Portable Load Bank intended for small-medium capacity shop or fi eld use by engine generator dealers and service shops for maintenance, testing and performance proving of engine generator sets, UPS and other power systems in the 50–400KW range. The Merlin is available in discrete model sizes of 100KW, 150KW, 200KW, 250KW, 300KW, 350KW and 400KW.
The Merlin control panel includes test instrumentation, load application switches, operation indicator lights and fan/control power switch. The Load Bank includes rugged “Powr-Web” load elements, load control contactors, branch circuit fuse protection of the load elements, high temperature power wiring, cooling fan with circuit breaker, control power fuses. The Load Bank is protected against fan failure, high intake air temperature, high exhaust air temperature, and overvoltage. The unit includes a 12’ connection cable set.
MERLIN
100KW - 400KW Load Bank
Merlin Load Banks are built on a formed and welded steel chassis that is both rugged and lightweight. For fl exible portability, the Merlin includes casters, lifting eyes and forklift channels. Airfl ow through the unit is horizontal with cooling provided by a cast aluminum airfoil type shrouded propeller fan.
Features
• Exceptionally rugged, all welded, formed steel chassis
• Hinge-open control section door
• Lifting eyes, forklift channels and casters
• Moving handle
• “PowrWeb” Load Elements
• Branch circuit fuse protection
Insight
Onsite
®
MERLIN
100KW - 400KW Load Bank • Page 2
Powr-Web Resistive Load Element
Description
Simplex Load Banks utilize the “Powr­Web” Load Element (a UL Recognized Component). The “Powr-Web” is an advanced design, air-cooled power resistor specifi cally designed for application to load bank systems. The “Powr-Web” is conservatively operated at half the maximum temperature rating of the alloy and features a short-circuit­safe design based on continuous mechanical support of the resistor by high temperature, ceramic clad stainless steel rods.
Construction
®
• Precision calibrated to specifi c ohmic value
• All load elements are continuously supported by vibration resistant, ceramic clad, stainless steel through­rods.
Specifi cations
• Alloy: FeCrAl
• Maximum continuous temperature rating: 1920°F
• Maximum operating temperature as applied in Load Bank: 1080° F
• Cool down time from operating to ambient temperature is 10 seconds.
Branch Circuit Fuse Protection
The load of a resistive load bank consists of a dense array of open, uninsulated power resistors mounted within a cooling air stream. Since the elements are electrically live, it is possible for a foreign object to penetrate the element array and create a short circuit of adjacent elements or a short to ground. Since the elements are densely packed, it is possible for a short circuit, once started, to rapidly propagate through the entire element array. As a load bank represents a relatively
large amount of power concentrated within a relatively small volume, a self­propagating, cascading short circuit would have catastrophic results.
Simplex virtually eliminates the dangers of short circuit through the
use of branch circuit fuse protection of the load elements. Per NEC 110-10, protective devices shall clear a fault without “extensive damage” to the circuit components. A Simplex Load Bank is divided into branch circuits of not more than 50 KW each.
Simplex, Inc. 5300 Rising Moon Road Springfi eld, IL 62711-6228
217-483-1600 Fax 217-483-1616 www.simplexdirect.com
© 2012 Simplex, Inc. All Rights Reserved. Printed in the USA • 1103-03.01 Design subject to change without notice.
Insight
Onsite
MERLIN
100KW - 400KW Load Bank • Page 3
KW , 1.0 P.F. COOLING FAN LOAD STEPS
240/480V,
Model
Merlin 100 100 75 63 67 0.75 120V/240V, 1-ph. 6000 5, 10, 10, 25, 50
Merlin 150 150 112 94 100 .75 120V/240V, 1-ph. 6000 5, 10, 10, 25, 50, 50
Merlin 200 200 150 125 134 1.5 120V/240V, 1-ph. 6700 5, 10, 10, 25, 50, 100
Merlin 250 250 188 157 167 1.5 120V/240V, 1-ph. 6700 5, 10, 10, 25, 50, 50, 100
Merlin 300 300 225 188 200 1.5 120V/240V, 1-ph. 6700 5, 10, 10, 25, 50, 100, 100
Merlin 350 350 262 219 233 3.0 240/480V, 3-ph. 8000 5, 10, 10, 25, 50, 50, 100, 100
Merlin 400 400 300 250 267 3.0 240/480V, 3-ph. 8000 5, 10, 10, 25, 50, 100, 100, 100
3-phase
Fan/Control Power
User selectable, internal/external
Internal Power
Merlin 100, Merlin 150: 120V, 1-ph, 2-wire, 60Hz 240V, 1-ph, 3-wire, 60Hz 208-240V, 3-ph, 4-wire, 60Hz Optional: 416-480V, 3-ph, 3-wire, 60Hz Optional: 50Hz Voltages
Merlin 200 through Merlin 300: 120V, 1-ph, 2-wire, 60Hz 240V, 1-ph, 3-wire, 60Hz 208-240V, 3-ph, 4-wire, 60Hz 416-480V, 3-ph, 3-wire, 60Hz Optional: 50Hz Voltages
Merlin 350 through Merlin 400: 190-205V, 3-ph, 3-wire, 50Hz 208V-240V, 3-ph, 3-wire, 60Hz 380-416V, 3-ph, 3-wire, 50Hz 416-480V, 3-ph, 3-wire, 60Hz
208/416V,
3-phase
190/380V,
3-phase
240V,
1-phase HP Voltage CFM KW @ 240/480V, 3-phase
External Power
Merlin 100, Merlin 150: 115V, 1-ph, 60Hz, 15A
Merlin 200 through 300: 115V, 1-ph, 60Hz, 20A
Merlin 350, Merlin 400: 230/460V, 3-ph, 50/60Hz, 20A
Voltage
High/Low Mode, operator selectable High: 250-480VAC, 3-ph. Low: to 240VAC, 3-ph. Optional: 1-ph.
Frequency
60Hz; Optional: 50, 400Hz
Duty Cycle
Continuous
Temperature Rating
125° F max intake air temp
Nominal 110° F rise
Power Connection
Merlin 100 through Merlin 300: 4-wire plus ground
Merlin 350, Merlin 400: 3-wire plus ground
© 2012 Simplex, Inc. All Rights Reserved.
Printed in the USA • 1103-03.01
Design subject to change without notice.
217-483-1600
Fax 217-483-1616
www.simplexdirect.com
Simplex, Inc.
5300 Rising Moon Road
Springfi eld, IL 62711-6228
MERLIN
100KW - 400KW Load Bank • Page 4
®
Dimensions and Key Features
1
H
Model W D H
Merlin 100KW, 150KW 31” 47” 43”
Merlin 200KW, 250KW, 300KW 31” 56” 50”
Merlin 350KW, 400KW 31” 69” 50”
WD
53
9
6
EXHAUST
AIR
4
8
10
11
INTAKE
AIR
2
7
RIGHT VIEW REAR VIEW LEFT VIEW
1. 12' Cable Set
2. Forklift Channels
3. Lockable Latch
4. Screened Intake and Exhaust
5. Hinged Access Door to Control Panel
6. Removeable Panel to Access Elements
7. Casters
8. External Control Power Cable
9. Hinged Access Door to Fuses and Contactors
10. Hand Grip for Moving and Cable Storage
11. Removeable Panel to Access Fan
Merlin 300 with optional Cam-Lok connectors
Simplex, Inc. 5300 Rising Moon Road Springfi eld, IL 62711-6228
217-483-1600 Fax 217-483-1616 www.simplexdirect.com
© 2012 Simplex, Inc. All Rights Reserved. Printed in the USA • 1103-03.01 Design subject to change without notice.
Loading...