INNOVATIVE TEST SYSTEMS... GLOBAL TEST SOLUTIONS
MCL488
MULTI-CHANNEL LOADS
Plug & Play
FEATURES
• Front Panel, Analog IEEE 488, or
RS232 Control
• 60 Amp, 350 Watt Modules
30 Amp, 175 Watt Modules
• Channels in 50V, 100V, 400V, or
600V Configurations
• Paralleling Channels for
Simultaneous control
• Operation to a Fraction of a Volt
• Current, Resistance, Voltage and
Power Loading
• Pulse Operation, Including
Three Step Staircase
• Channels May be Easily Added
in the Field
PRODUCT OVERVIEW
The MCL488 series of multi-channel electronic loads are ideal for ATE system and bench-top applications that require
a multiple channel load with maximum flexibility. Each system consists of a sub-rack housing and modules. The load
modules are rated at 50V, 100V, 400V or 600V and are rated for 175 watt and 350 watt operation. Up to 10 modules
fit into a 19"W x 10.5"H x 23"D sub-rack. The MCL488 is easily upgraded in the field by adding modules.
Once in the sub-rack, the modules are user configurable. The load modules can be paralleled using the paralleling
straps provided, configured either from the front panel or computer bus, and controlled as a single channel. 350 watt
and 175 watt modules may be used in any configuration, providing maximum flexibility. All functions that are
available for a single module are available in the multi-channel configuration.
Complete operation including Constant Current, Constant Resistance, Constant Power and Constant Voltage is available
when operating a single module or when the modules are paralleled. All functions, including linking modules in
parallel through software, are programmed via the user-friendly front panel, IEEE-488 bus or the optional RS232
interface. The front panel simultaneously displays voltage, current, wattage and mode for each installed module.

UP TO 10 CHANNELS CONTROLLED FROM A SINGLE IEEE-488 ADDRESS
175 Watt Module
350 Watt
Module
MCL488
The user enabled password protection locks out the front panel for ATE applications. Front panel control can be
restored by entering a user selectable four-digit pass code.
CP*
HI
CHANNEL
FAULT
0
1
2
3
4
5
6
7
8
9
6
5.04V
115.1A
580W
CI* WF
CHANNEL
MODES
CI
CP
EXT
PROG
SLAVE
CHANNEL
10.54V
+
CV
CR
LOW
CR
HIGH
SHORT
7
12.8A
135W
CP*
CI: 60.00 A
TYPE: 400V/60A
1
4
7
•
CHANNEL8CHANNEL
9
5.04V
115.1A
580W
CI* WF
2
5
8
0
3
6
9
ENTER
CLEAR
<-LINK
MAN
ADJ
V
A
W
CHANNEL
0
10.54V
12.8A
135W
CP*
CHANNEL
1
5.04V
115.1A
580W
CI* WF
CHANNEL
2
10.54V
12.8A
135W
CP*
CHANNEL3CHANNEL
4
5.04V
115.1A
580W
CI* WF
<-LINK
V
A
W
DC LOAD
ON/
OFF
REMOTE
LOCAL
AC
POWER
RUN
FREQ
DUTY
CYCLE
MEM
PULSE
CHANNEL
5
10.54V
12.8A
135W
PEAK
t
LO
t
MENU
www.tdipower.com
Transister Devices, Inc. • 36 Newburgh Road, Hackettstown, NJ 07840 • Phone: 908.850.5088 • Fax: 908.850.5731 2

INNOVATIVE TEST SYSTEMS... GLOBAL TEST SOLUTIONS
ANALOG MODE
Ext. Prog: 0 to 10 Volts input yields 0 to full scale loading in
all operating modes.
Input Impedance: 330K Ohms
Prog. Response: Limited by internal adjustable slew rate limiter
Pulse Mode: Two level or three level pulsing
available in any mode.
Min Pulse
Duration(Any level): 10mSec
Max Pulse
Duration(Any level): 16 Sec or 71 Min. with
reduced resolution and minimum duration
Resolution: 1mSec
Adjustable Slew Rate:
Max: 0 to full scale in 10µS
Min: 0 to full scale in 10mS
OUTPUT SIGNALS
Current Sample Output:
Scaling: 10 Volts = full scale Current
Accuracy: ±0.5% of full scale
PROTECTION
Current Limit: 105% of full scale current
Power Limit: Approximately 370 Watts
Overvoltage: Load disconnect at approximately 105% of full
scale voltage
Thermal: Load disconnect at internal temperature of 105°C
Undervoltage: Load inhibited at less than1 Volt, when enabled
METERS
Voltmeter Accuracy:±0.25%, ±1 Digit
Ammeter Accuracy: ±0.25%, ±1 Digit
Wattmeter Accuracy: ±0.5%, ±2 Digits
IEEE-488 READBACKS
Current:
Resolution: 1/4000 of Full Scale
Accuracy: ±0.5% ±1 Digit
Voltage:
Resolution: 1/4000 of Selected Full Scale
Accuracy: ±0.5% ±1Digit
Power:
Resolution: 87.5 mW
Accuracy: ±0.5% ±1Digit
MECHANICAL
Module Size: 1.58”W x 10.5”H x 24”D
40mm W x 267mm H x 610mm D
Module Weight: 12 lbs. / 5.44kg
Chassis Size: 19”W x 10.5”H x 24”D
483mm W x 267mm H x 610mm D
Rack Mountable
Full Chassis Weight: 125 lbs. / 56.70kg
MISCELLANEOUS
AC Input: User Selectable
110VAC/220VAC,±10%, 48 - 62Hz @ 350W
Ambient Temp: 0°C to 40°C
SERIES SPECIFICATIONS
CHASSIS OUTLINE

4
MCL488 50-100-350 MCL488 100-60-350
OPERATING MODES
Constant Current: 0 to 100A
Prog. Accuracy: ±0.50%
Regulation: 100mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 200 A/V
Low Res. Mode: Infinite - 0.005Ω
Low A/V Mode: 0 - 20 A/V
High Res. Mode: Infinite - 0.05Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 50V
Prog. Accuracy: ±0.50%
Regulation: ±0.075V
Constant Power: 0 to 350 Watts
Prog. Accuracy: 10 Watts
Regulation: 10 Watts
Short Circuit: 0.004Ω Max.
INPUT CHARACTERISTICS:
OPERATING MODES
Constant Current: 0 to 60A
Prog. Accuracy: ±0.25%
Regulation: 60mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 60 A/V
Low Res. Mode: Infinite - 0.0167Ω
Low A/V Mode: 0 - 6 A/V
High Res. Mode: Infinite - 0.167Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy: ±0.5%
Regulation: ±0.15V
Constant Power: 0 to 350 Watts
Prog. Accuracy: 10 Watts
Regulation: 10 Watts
Short Circuit: 0.016Ω Max.
INPUT CHARACTERISTICS:
MODULE SPECIFICATIONS
0.1
1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
0.1 1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
MCL488 100-15-350
OPERATING MODES
Constant Current: 0 to 15A
Prog. Accuracy: ±0.25%
Regulation: 2mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 15 A/V
Low Res. Mode: Infinite - 0.666Ω
Low A/V Mode: 0 - 1.5 A/V
High Res. Mode: Infinite - 6.66Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy: ±0.5%
Regulation: ±0.15V
Constant Power: 0 to 350 Watts
Prog. Accuracy: 10 Watts
Regulation: 10 Watts
Short Circuit: 0.016Ω Max.
INPUT CHARACTERISTICS:
0.1
1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
Transistor Devices, Inc. • 36 Newburgh Road, Hackettstown, NJ 07840 • Phone: 908.850.5088 • Fax: 908.850.5731

INNOVATIVE TEST SYSTEMS... GLOBAL TEST SOLUTIONS
MCL488 100-30-175
OPERATING MODES
Constant Current: 0 to 30A
Prog. Accuracy: ±0.25%
Regulation: 30mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 30 A/V
Low Res. Mode: Infinite - 0.0333Ω
Low A/V Mode: 0 - 3 A/V
High Res. Mode: Infinite - 0.333Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy: ±0.50%
Regulation: ±0.15V
Constant Power: 0 to 175 Watts
Prog. Accuracy: 5 Watts
Regulation: 5 Watts
Short Circuit: 0.06Ω Max.
INPUT CHARACTERISTICS:
MODULE SPECIFICATIONS
0.1 1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
0.1 1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
MCL488 600-20-350
OPERATING MODES
Constant Current: 0 to 20A
Prog. Accuracy: ±0.25%
Regulation: 20mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 3 A/V
Low Res. Mode: Infinite - 0.333Ω
Low A/V Mode: 0 - 0.333 A/V
High Res. Mode: Infinite - 3Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 600V
Prog. Accuracy: ±0.5%
Regulation: ±0.9V
Constant Power: 0 to 350 Watts
Prog. Accuracy: 10 Watts
Regulation: 10 Watts
Short Circuit: 0.33Ω Max.
INPUT CHARACTERISTICS:
MCL488 400-60-350
OPERATING MODES
Constant Current: 0 to 60A
Prog. Accuracy: ±0.25%
Regulation: 60mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 15 A/V
Low Res. Mode: Infinite - 0.0667Ω
Low A/V Mode: 0 - 1.5 A/V
High Res. Mode: Infinite - 0.667Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 400V
Prog. Accuracy: ±0.25%
Regulation: ±0.6V
Constant Power: 0 to 350 Watts
Prog. Accuracy: 10 Watts
Regulation: 10 Watts
Short Circuit: 0.08Ω Max.
INPUT CHARACTERISTICS:
0.1 1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS

6
MCL488 400-30-175
OPERATING MODES
Constant Current: 0 to 30A
Prog. Accuracy: ±0.25%
Regulation: 30mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 7.5 A/V
Low Res. Mode: Infinite - 0.1333Ω
Low A/V Mode: 0 - .75 A/V
High Res. Mode: Infinite - 1.333Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 400V
Prog. Accuracy: ±0.25%
Regulation: ±0.6V
Constant Power: 0 to 175 Watts
Prog. Accuracy: 5 Watts
Regulation: 5 Watts
Short Circuit: 0.16Ω Max.
INPUT CHARACTERISTICS:
MCL488 600-10-175 MCL488 100-5-175
OPERATING MODES
Constant Current: 0 to 10A
Prog. Accuracy: ±0.25%
Regulation: 10mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 1.5 A/V
Low Res. Mode: Infinite - 0.666Ω
Low A/V Mode: 0 - 1.5 A/V
High Res. Mode: Infinite - 6.66Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 600V
Prog. Accuracy: .5%
Regulation: ±1.8V
Constant Power: 0 to 175 Watts
Prog. Accuracy: ±5 Watts
Regulation: ±5 Watts
Short Circuit: 0.66Ω Max.
INPUT CHARACTERISTICS:
OPERATING MODES
Constant Current: 0 to 5A
Prog. Accuracy: ±0.25%
Regulation: 5mA
Constant Resistance: Amps/Volt or Ohms
High A/V Mode: 0 - 5 A/V
Low Res. Mode: Infinite - 0.2Ω
Low A/V Mode: 0 - .5 A/V
High Res. Mode: Infinite - 2.0Ω
Prog. Accuracy: ±3% of Full Scale
Regulation: ±3% of Full Scale
Constant Voltage: 0 - 100V
Prog. Accuracy: ±0.5%
Regulation: ±0.15V
Constant Power: 0 to 175 Watts
Prog. Accuracy: ±5 Watts
Regulation: ±5 Watts
Short Circuit: 0.06Ω Max.
INPUT CHARACTERISTICS:
MODULE SPECIFICATIONS
0.1
1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
0.1
1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
0.1 1 10010 1000
0.1
1
10
100
1000
AMPERES
VOLTS
Transister Devices, Inc • 36 Newburgh Road, Hackettstown, NJ 07840 • Phone: 908.850.5088 • Fax: 908.850.5731