M4100
Technical Specifications
The M4100 unit is the foundation of the M4000 Diagnostic Test System for Condition
Assessment of Power Apparatus
Note: A personal computer is required to operate the M4100
Power Specifications:
Output Voltage: 0 to 12 kV AC
Output Current:
200 mA > 30 minutes at 10 kV
300 mA > 4 minutes at 10 kV
Operating time period based on 50°C operating temperature. Longer durations at high
currents will be realized at lower operating
temperatures
Output Power:
Sinusoidal output signal internal generated
independent of input supply, No loss in performance when used with portable generator
A.C. Input
16 A max at 110 V,
10 A max at 220 V
100 mA continuous at 10 kV
3 kVA
*
: 95-264 V AC 47 to 63 Hz
Measurement, Accuracy and
Range Test Frequency:
Test Frequency:
Range: 45 to 70 Hz independent
of input signa
Resolution: 0.1 Hz
Accuracy:
Test Voltage:
Range: 25 V to 12 kV
Resolution:
Accuracy:
±1% of reading
1 V
±1% of reading, ±1 V
l
Capacitance:
Range: 0 to 100 µF
Resolution:
Accuracy:
0.01 rF
± 0.5% of reading, ± 1 rF
Inductance:
Range: 6 H to 10 MH
Resolution:
Accuracy:
Watts:
Range: 0 to 2 kW, actual
Resolution:
Accuracy:
± 0.03% of VA, ±0.5 mW
0.01 H
± 0.5% of reading
0.5 mW
± 2% of reading at 10 kV,
Dissipation Factor:
Range:
%PF
0 to ±100.00%
PF
0 to ±1.0000
% Tan d
0 to ±999.99%
Tan d
0 to ±9.9999
mW/Var
Resolution:
Accuracy:
0 to ±9999.9
0.01% / 0.0001
± 0.5% of reading, typical
±0.04% PF/Tan d
±0.0004 PF/Tan d
Test Current:
Range: 0 to 5.0 A
Resolution:
Accuracy:
*
0.1 µA
±1% of reading, ±1 µA
There are power restrictions for input
voltages below 190 V AC.
Temperature Measurement:
Range: -20 °C to +50 °C
Resolution:
Accuracy:
Requires optional temperature probe
0.1 °C
±4 °C
STANDARDS
EMC Emissions
FCC 47 CFR Part 15 Class A Emissions requirements (USA)
EN 55011:1998/A1:1999/A2:2002 Group 1 Class A ISM Emissions requirements (EUROPE)
AS/NZS CISPR 11:2004 Class A ISM Emissions requirements (Australia)
ENVIRONMENTAL
Temperature:
Operating: -20 °C to +50 °C
Storage:
-40 °C to +70 °C
Humidity:
90% non-condensing
DIMENSIONS
Instrument: 10-1/4 in. H x 20 in. W x
25-1/4 in. D 26 cm H x
50.8 cm W x 64.1 cm D
High Voltage Cable:
Weights
Instrument: 95 lbs/45.5 kg
60 ft./18 mt (other lengths
available as options)
MAXIMUM INTERFERENCE
CONDITIONS AT LINE
EMC Immunity
EN 61326:1997/A1:1998/A2:2001/A3:2003
IEC 61000-4-2/3/4/5/6/11
IEC 801-2(1984) Electrostatic Discharge
ANSI/IEEE C37.90.1 Surge Withstand Capability
SAFETY
EN 61010-1 :2001 (2nd Edition)
ENVIROMENTAL
IEC 60068-2-2 Dry Heat
IEC 60068-2-1 Cold
IEC 60068-2-30 Damp Heat
MECHANICAL
IEC 60068-2-27 Shock
IEC 60068-2-6 Vibration
IEC 60068-2-6 Drop test
ASTM D999.75 Transport Shock Test
Specifications are subject to change without notice.
Frequency
Electrostatic: 15 mA rms of interference
current into any lead or
cable with no loss of
measurement accuracy.
Applicable to a maximum
ratio of interference
current to specimen
current of 20:1.
Electromagnetic:
For more information, contact
M4000@doble.com
Doble Engineering Company
85 Walnut Street
Watertown, MA 02472 USA
tel +1 617 926 4900
fax +1 617 926 0528
TOGETHER WE POWER THE WORLD
500 µT, at 50 Hz in any
direction
The M4100 unit is the foundation of the M4000 Diagnostic
Test System for Condition Assessment of Power Apparatus
Doble is certified ISO 9001:2000
MKT-SL-M4100TS-12/08