Atec CSS500N10 User Manual

DATA SHEET > CSS 500N10 > 20130626
CSS 500N10
CURRENT SURGE GENERATOR, 8/20US UP TO 10KA
FOR TESTS ACCORDING TO ...
> EN 300386 V1.3.2 > EN 61000-4-5 > IEC 61000-4-5 > IEC 61326 > IEC 61850-3 > ITU-T K.12 > ITU-T K.20 > ITU-T K.21 > ITU-T K.45
CURRENT SURGE SIMULATOR FOR COMPONENT TESTING
Various current surge pulses are specified to determine the characteristics of a protection device such as a varistor. Typically current surge pulses such as 8/20us, 10/350us or 10/1,000us are applied to test such components.
Within the range of current surge generators EM TEST is offering solutions for small energy varistors with test currents up to 1,200A as well as generators ranging up to 10kA (8/20us surge current) or 4kA (10/350us surge current).
HIGHLIGHTS
> Surge current 8/20us up to 10kA
APPLICATION AREAS
INDUSTRY
RESIDENTIAL
> Built-in voltage/current monitors (depending on
model)
COMPONENTS
> Interlock > Warning lamp control > Test box with interlock (option)
MEDICAL
BROADCAST
> USB (optical link) and GPIB interface
TELECOM
www.emtest.com © EM TEST > PAGE 1/3
DATA SHEET > CSS 500N10 > 20130626
TECHNICAL DETAILS
CSS 500N10 SURGE CURRENT GENERATOR
WAVE SHAPE 8US/20US
Output voltage (open circuit)
Output current (short circuit)
Front time 8us +/-20% Time to half value 20us +/-20% Undershoot Max. 20%
TRIGGER
Trigger of events Automatic, manual, external External External pulse release Repetition rate Max. 10 pulses per minute,
Counter 1 to 30,000 or endless
250V to 6,000V +/-10%, Step width 50V
0.4kA to 10kA +/-10%
depending on the charging voltage
SAFETY
Safety circuit Control input (24Vdc) Warning lamp Floating output contact Safety interlock Security switch off (with test box)
GENERAL DATA
Dimensions, weight
Supply voltage 115/230V +10/-15% Fuses 2 x T1AT (230V) or 2 x T2AT (115V)
19"/6HU, approx. 30kg
OUTPUT
Direct Via high current connector
Optional: Test box
Polarity Positive, negative, alternating
MEASUREMENTS
CRO I-monitor 10Vp at 10kA CRO V-monitor 6Vp at 6kV Peak current 10kA in the LCD display Peak voltage 6kV in the LCD display
TEST ROUTINES
Quick Start Immediate start; easy-to-use and
fast
User Test routines Change polarityafter n pulses
Change charging voltage after n pulses
Customer specific test routines
Service Service, set-up, self test
INTERFACE
Optical interface Opto link, 3 m cable
USB A connector
Parallel interface IEEE 488, addresses 1 to 30
www.emtest.com © EM TEST > PAGE 2/3
Loading...
+ 1 hidden pages