General technical specifications ................................................................................................................................... 8
Power meter ...................................................................................................................................................................................... 11
Possible configurations with two RF paths .......................................................................................................................................... 14
Configuration with two H570 (RF TRX) and two H590A (RF frontend (BASIC)) ............................................................................... 14
Configuration with two H570 (RF TRX) and one H590D (RF frontend (ADV.)) ................................................................................ 14
Possible configurations with four RF paths .......................................................................................................................................... 15
Configuration with two H570 (RF TRX), two H571B (RF TX) and two H590D (RF frontend (ADV.)) ............................................... 15
Configuration with four H570 (RF TRX) and two H590D (RF frontend (ADV.)) ................................................................................ 16
Reference frequency inputs/outputs .................................................................................................................................................. 17
Connectors AF 1 IN / AF 2 IN ............................................................................................................................................................ 18
AF voltmeter ...................................................................................................................................................................................... 18
THD+N and THD meter ..................................................................................................................................................................... 18
Connectors AF 1 OUT / AF 2 OUT .................................................................................................................................................... 18
AF sine generator .............................................................................................................................................................................. 18
Digital interface unbalanced .................................................................................................................................................................. 19
GSM specifications – mobile station test .................................................................................................................. 20
Power versus time measurement ...................................................................................................................................................... 22
Spectrum due to modulation measurement ...................................................................................................................................... 22
Spectrum due to switching measurement ......................................................................................................................................... 22
CMW-KS210 option and R&S®CMW-KS211) ............................................................................................. 22
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
WCDMA specifications – mobile station (UE) test .................................................................................................... 23
Power meter ...................................................................................................................................................................................... 25
LTE specifications – mobile station test .................................................................................................................... 27
Power measurement ......................................................................................................................................................................... 29
Power measurement ......................................................................................................................................................................... 31
DL signal ........................................................................................................................................................................................... 32
Power measurement ......................................................................................................................................................................... 33
Power measurement ......................................................................................................................................................................... 35
FM STEREO RADIO specifications .............................................................................................................................. 40
FM STEREO RADIO generator (prerequisite: R&S®CMW-B110A/R&S®CMW-B110D option) ............................................................ 40
FM STEREO RADIO waveforms (R&S®CMW-KV645 option) .......................................................................................................... 40
FM STEREO RADIO analyzer (R&S®CMW-KM645 option) ................................................................................................................. 41
WLAN N switched MIMO RF analyzer (R&S®CMW-KM653 option) ..................................................................................................... 46
Features ............................................................................................................................................................................................ 50
4 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
WiMAX™ specifications – mobile station and base station test .............................................................................. 51
Power measurement ......................................................................................................................................................................... 52
Features ............................................................................................................................................................................................ 55
WiMAX™ IP application enabler (prerequisite: R&S®CMW-KA700, R&S®CMW-B660, R&S®CMW-B661 options)............................. 55
TD-SCDMA specifications – mobile station (UE) test ............................................................................................... 56
Power meter ...................................................................................................................................................................................... 58
Power meter ...................................................................................................................................................................................... 61
Power meter ...................................................................................................................................................................................... 65
Data application unit (R&S®CMW-B450A/R&S®CMW-B450B option) ..................................................................... 66
Data application .................................................................................................................................................................................... 66
IP multimedia subsystem server (R&S®CMW-KAA20 option) .............................................................................................................. 66
Data application measurements (R&S®CMW-KM050 option)............................................................................................................... 66
IP analysis (R&S®CMW-KM051 option) ................................................................................................................................................ 66
LAN DAU interface ................................................................................................................................................................................ 66
Digital I/Q 1 to 4 (R&S®CMW-B510F option) and digital I/Q 5 to 8 (R&S®CMW-B520F option) .............................. 67
Digital I/Q interface ............................................................................................................................................................................... 67
AUX interface ........................................................................................................................................................................................ 67
Included extras ...................................................................................................................................................................................... 67
General data .................................................................................................................................................................. 68
Ordering information .................................................................................................................................................... 70
Recommended extras for manual operation ......................................................................................................................................... 70
Service options ..................................................................................................................................................................................... 71
6 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Specifications apply under the following conditions:
Data valid for the R&S
®
CMW500, the R&S®CMW280 and the R&S®CMW270 unless otherwise stated.
Data without tolerance limits is not binding. Based on a 24-month calibration interval unless otherwise stated. At least 15 minutes
warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal automatic
adjustments performed. Typical values are designated with the abbreviation “typ.”. These values are verified during the final test but
are not assured by Rohde & Schwarz. Nominal values are design parameters that are not assured by Rohde & Schwarz. These values
are verified during product development but are not specifically tested during production.
In line with the 3GPP/3GPP2 standard, chip rates are specified in Mcps (million chips per second), whereas bit rates and symbol rates
are specified in Mbps (million bits per second), kbps (thousand bits per second) or ksps (thousand symbols per second), and sample
rates are specified in Msample/s (million samples per second). Mcps, kbps, ksps and Msample/s are not SI units.
During the production process, each instrument is calibrated in line with defined procedures. All measurement results, including
measurement uncertainties of the calibration system, have to be within the published specification limits to release the individual
instrument. The expanded measurement uncertainties of the calibration system used in the production process are determined with a
coverage factor of k = 2 (normally approx. 95 % probability).
Parameters written in italics can be set directly on the tester.
CDMA2000
®
is a registered trademark of the Telecommunications Industry Association (TIA - USA).
“WiMAX Forum” is a registered trademark of the WiMAX Forum. “WiMAX”, the WiMAX Forum logo, “WiMAX Forum Certified” and the
WiMAX Forum Certified logo are trademarks of the WiMAX Forum.
The Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by
Rohde & Schwarz is under license.
Data without tolerance limits is not binding.
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 7
Version 11.00, May 2013
General technical specifications
RF generator
Frequency range 70 MHz to 3300 MHz,
Frequency resolution 0.1 Hz
Frequency uncertainty same as timebase + frequency resolution
Output level range
RF1 COM, RF2 COM 70 MHz to 100 MHz
continuous wave (CW) –130 dBm to –15 dBm
peak envelope power (PEP) up to –15 dBm
overranging (PEP) up to –10 dBm
100 MHz to 3300 MHz
continuous wave (CW) –130 dBm to –5 dBm
peak envelope power (PEP) up to –5 dBm
overranging (PEP) up to 0 dBm
3300 MHz to 6000 MHz
continuous wave (CW) –120 dBm to –15 dBm
peak envelope power (PEP) up to –15 dBm
overranging (PEP) up to –10 dBm
maximum input DC level 0 V DC
RF1 OUT 70 MHz to 100 MHz
continuous wave (CW) –120 dBm to –7 dBm
peak envelope power (PEP) up to –7 dBm
overranging (PEP) up to +3 dBm
100 MHz to 3300 MHz
continuous wave (CW) –120 dBm to +3 dBm
peak envelope power (PEP) up to +3 dBm
overranging (PEP) up to +13 dBm
3300 MHz to 6000 MHz
continuous wave (CW) –110 dBm to –7 dBm
peak envelope power (PEP) up to –7 dBm
overranging (PEP) up to +3 dBm
maximum input DC level 0 V DC
Output level uncertainty in temperature range +20 °C to +35 °C,
no overranging
RF1 COM, RF2 COM output level > –120 dBm
70 MHz to 100 MHz < 1.2 dB 1
100 MHz to 3300 MHz < 0.6 dB 1
3300 MHz to 6000 MHz < 1.2 dB 1
RF1 OUT output level > –112 dBm
70 MHz to 100 MHz < 1.6 dB 1
100 MHz to 3300 MHz < 0.8 dB 1
3300 MHz to 6000 MHz < 1.6 dB 1
Output level uncertainty in temperature range +5 °C to +45 °C,
no overranging
RF1 COM, RF2 COM output level > –120 dBm
70 MHz to 100 MHz < 2.0 dB 1
100 MHz to 3300 MHz < 1.0 dB 1
3300 MHz to 6000 MHz < 2.0 dB 1
RF1 OUT output level > –112 dBm
70 MHz to 100 MHz < 2.0 dB 1
100 MHz to 3300 MHz < 1.0 dB 1
3300 MHz to 6000 MHz < 2.0 dB 1
up to 6000 MHz with the
®
R&S
CMW-KB036 option
1
Valid for a 12-month calibration interval.
®
8 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Output level linearity with fixed RF
output attenuator setting
in temperature range +20 °C to +35 °C,
GPRF generator list mode,
level range 0 dB to –30 dB
RF1 COM, RF2 COM no overranging < 0.2 dB, typ. < 0.1 dB
Output level resolution 0.01 dB
Output level repeatability typical values after 1 h warm-up time,
always returning to same level and
frequency, no temperature change,
insignificant time change
output level ≥ –80 dBm < 0.01 dB
output level < –80 dBm < 0.05 dB
VSWR
RF1 COM, RF2 COM 70 MHz to 3300 MHz < 1.2
3300 MHz to 5000 MHz < 1.5
5000 MHz to 6000 MHz < 1.6
RF1 OUT 70 MHz to 3300 MHz < 1.5
3300 MHz to 5000 MHz < 1.5
5000 MHz to 6000 MHz < 1.6
Attenuation of 2nd harmonic
RF1 COM, RF2 COM 70 MHz to 6000 MHz, P < –10 dBm > 30 dB
RF1 OUT 70 MHz to 6000 MHz, P < 0 dBm > 30 dB
Attenuation of 3rd harmonic
RF1 COM, RF2 COM 70 MHz to 6000 MHz, P < –10 dBm > 40 dB
RF1 OUT 70 MHz to 6000 MHz, P < 0 dBm > 40 dB
Attenuation of nonharmonics > 5 kHz offset from carrier,
for output level > –40 dBm,
for full scale CW signal
400 MHz to 3300 MHz,
except f
except f
except f
= 3900 MHz – f
nonharmonic
= 3900 MHz,
nonharmonic
= (899 to 901) MHz +
carrier
carrier
,
> 60 dB
n × 800 MHz with n = 1, 2, 3
3300 MHz to 3600 MHz > 25 dB
3600 MHz to 6000 MHz,
except f
nonharmonic
= 2 × f
– 6400 MHz
carrier
> 40 dB
Phase noise single sideband, 70 MHz to 3300 MHz
Carrier offset ≥ 1 MHz < –120 dBc, 1 Hz
Phase noise single sideband, 3300 MHz to 6000 MHz
Carrier offset ≥ 1 MHz < –117 dBc, 1 Hz
Signal-to-noise ratio 70 MHz to 3300 MHz
RF1 COM, RF2 COM 5 MHz offset from carrier,
Frequency resolution 0.1 Hz
Resolution bandwidths Gaussian, 1 kHz to 10 MHz, in 1/3/5 steps,
Expected nominal power setting range for ADC full scale
RF1 COM, RF2 COM 70 MHz to 100 MHz –37 dBm to +42 dBm 2
100 MHz to 3300 MHz –47 dBm to +42 dBm 2
3300 MHz to 6000 MHz –37 dBm to +42 dBm 2
Level range
RF1 COM, RF2 COM 70 MHz to 100 MHz
continuous power (CW) –74 dBm 3 to +34 dBm
peak envelope power (PEP) up to +42 dBm 2
100 MHz to 3300 MHz
continuous power (CW) –84 dBm 3 to +34 dBm
peak envelope power (PEP) up to +42 dBm 2
3300 MHz to 6000 MHz
continuous power (CW) –74 dBm 3 to +34 dBm
peak envelope power (PEP) up to +42 dBm 2
maximum input DC level 0 V DC
Level uncertainty in temperature range +20 °C to +35 °C
RF1 COM, RF2 COM 70 MHz to 100 MHz < 1.0 dB 4
100 MHz to 3300 MHz < 0.5 dB 4
3300 MHz to 6000 MHz < 1.0 dB 4
Level uncertainty in temperature range +5 °C to +45 °C
RF1 COM, RF2 COM 70 MHz to 100 MHz < 1.2 dB 4
100 MHz to 3300 MHz < 0.7 dB 4
3300 MHz to 6000 MHz < 1.2 dB 4
Level linearity with fixed expected
in temperature range +20 °C to +35 °C
nominal power setting
RF1 COM, RF2 COM level range 0 dB to –40 dB < 0.15 dB, typ. < 0.1 dB
Level resolution 0.01 dB
Level repeatability typical values after 1 h warm-up time,
always returning to same level and
frequency, no temperature change,
insignificant time change
input level ≥ –40 dBm < 0.01 dB
input level < –40 dBm < 0.03 dB
up to 6000 MHz with the
®
R&S
CMW-KB036 option
bandpass, 1 kHz to 30 MHz, in 1/3/5
steps, RRC, α = 0.1,
3.84 MHz, RRC, α = 0.22, WCDMA filter,
1.2288 MHz, CDMA filter
2
The maximum permissible continuous power is +34 dBm due to thermal limits.
3
RBW → 1 kHz.
4
Valid for a 12-month calibration interval.
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 11
Version 11.00, May 2013
Dynamic range 70 MHz to 3300 MHz, RBW → 1 kHz,
> 100 dB
with fixed expected nominal power setting
Expected nominal power setting for full dynamic range
RF1 COM, RF2 COM –8 dBm to +42 dBm 5
Dynamic range 3300 MHz to 6000 MHz, RBW → 1 kHz,
> 97 dB
with fixed expected nominal power setting
Expected nominal power setting for full dynamic range
RF1 COM, RF2 COM +2 dBm to +42 dBm 5
Spectrum measurements
FFT spectrum analyzer
Frequency range 70 MHz to 3300 MHz,
Frequency span 1.25 MHz, 2.5 MHz, 5 MHz, 10 MHz,
FFT length 1k, 2k, 4k, 8k, 16k
Detector peak, RMS
Dynamic range 70 MHz to 3300 MHz,
for FFT length → 16k and span → 5 MHz
(equivalent to RBW → 781 Hz)
Expected nominal power setting for full dynamic range
RF1 COM, RF2 COM –8 dBm to +42 dBm 5
Dynamic range 3300 MHz to 6000 MHz,
for FFT length → 16k and span → 5 MHz
(equivalent to RBW → 781 Hz)
Expected nominal power setting for full dynamic range
RF1 COM, RF2 COM +2 dBm to +42 dBm 5
RF spectrum analyzer
®
(R&S
CMW-KM010 option)
Frequency range 70 MHz to 3300 MHz,
Frequency span 0 Hz (zero span), 500 Hz to 3230 MHz,
Resolution bandwidth (RBW) 100 Hz to 10 MHz (additional 40 MHz in
Video bandwidth (VBW) 10 Hz to 10 MHz
Sweep time frequency sweep, depending on RBW,
VBW and span
zero span, depending on RBW and VBW 80 µs to 2000 s
Detector average, RMS, sample, min. peak, max.
Trigger frequency sweep free run
zero span video,
Dynamic range
70 MHz to 3300 MHz, RBW→ 1 kHz,
detector → RMS
Expected nominal power setting for full dynamic range
RF1 COM, RF2 COM –8 dBm to +42 dBm 5
Dynamic range 3300 MHz to 6000 MHz, RBW → 1 kHz,
detector → RMS
Expected nominal power setting for full dynamic range
RF1 COM, RF2 COM +2 dBm to +42 dBm 5
up to 6000 MHz with the
®
R&S
CMW-KB036 option
20 MHz, 40 MHz
> 100 dB
> 97 dB
up to 6000 MHz with the
®
R&S
CMW-KB036 option
up to 5930 MHz with the
®
R&S
CMW-KB036 option
zero span)
500 µs to 2000 s
peak, auto peak
BASE: external TRIG A, B
®
all R&S
CMW internal trigger sources
> 100 dB
> 97 dB
5
The maximum permissible continuous power is +34 dBm due to thermal limits.
®
12 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Level range see general technical specifications
Level uncertainty for center frequency and detector → peak see general technical specifications
Inherent spurious response see general technical specifications
Spurious response see general technical specifications
Harmonic response see general technical specifications
Configuration with two H570 (RF TRX) and two H590A (RF frontend (BASIC))
The R&S®CMW-B570 and R&S®CMW-B590A options make the second RF path (RF path 2) available on the front of the instrument
with three additional RF connectors, i.e. RF3 COM, RF4 COM and RF3 OUT.
RF3 COM equivalent to RF1 COM see general technical specifications
RF4 COM equivalent to RF2 COM see general technical specifications
RF3 OUT equivalent to RF1 OUT see general technical specifications
Configuration with two H570 (RF TRX) and one H590D (RF frontend (ADV.))
The R&S®CMW-B570 option and R&S®CMW-S590D selection make the second RF path (RF path 2) available on the front of the
instrument at connectors RF1 COM, RF2 COM and RF1 OUT.
RF path 1 and RF path 2 routed to separate connectors
RF generator 1 and RF generator 2 switchable to RF1 COM, RF2 COM,
RF analyzer 1 and RF analyzer 2 switchable to RF1 COM, RF2 COM see general technical specifications
Expected nominal power setting for full
dynamic range
Level range see general technical specifications,
RF path 1 and RF path 2 routed to common connector
RF generator 1 and RF generator 2 switchable to RF1 COM, RF2 COM,
Output level range peak envelope power (PEP) the specified value is valid for the total
Output level uncertainty for each carrier see general technical specifications,
Signal-to-noise ratio for the carrier with the highest output level
RF analyzer 1 and RF analyzer 2 switchable to RF1 COM, RF2 COM see general technical specifications
Level uncertainty 70 MHz to 3300 MHz see general technical specifications,
Expected nominal power setting for full
dynamic range
Level range see general technical specifications,
®
CMW-S590A RF frontend (BASIC) or R&S®CMW-S590D RF frontend (ADV.) and R&S®CMW-S570 RF TRX.
®
CMW-B590A RF frontend (BASIC) or R&S®CMW-B590D RF frontend (ADV.) and R&S®CMW-B570 RF TRX.
see general technical specifications
RF1 OUT
see general technical specifications,
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
RF1 OUT
(at least 3 dB higher than the other carrier)
3300 MHz to 6000 MHz see general technical specifications
see general technical specifications,
see general technical specifications
power of the two RF generators, see
general technical specifications
Configuration with two H570 (RF TRX), two H571B (RF TX) and two H590D (RF frontend (ADV.))
The R&S®CMW-B570 option, two R&S®CMW-B571 options and R&S®CMW-B590D option make the four RF paths (RF path 1 RX and
TX, RF path 2 RX and TX, RF path 3 TX only, RF path 4 TX only) available on the front of the instrument at connectors RF1 COM,
RF2 COM, RF1 OUT and RF3 COM, RF4 COM, RF3 OUT.
RF path 1, 2, 3 and 4 routed to separate connectors
RF generator 1 and RF generator 3 switchable to RF1 COM, RF2 COM,
RF generator 2 and RF generator 4 switchable to RF3 COM, RF4 COM,
RF analyzer 1 switchable to RF1 COM, RF2 COM see general technical specifications
Expected nominal power setting for full
dynamic range
Level range see general technical specifications,
RF analyzer 2 switchable to RF3 COM, RF4 COM see general technical specifications
Expected nominal power setting for full
dynamic range
Level range see general technical specifications,
RF path 1, RF path 3 routed to common connector and RF path 2, RF path 4 routed to common connector
RF generator 1 and RF generator 3 switchable to RF1 COM, RF2 COM,
Output level range peak envelope power (PEP) the specified value is valid for the total
Output level uncertainty for each carrier see general technical specifications,
Signal-to-noise ratio for the carrier with the highest output level
RF generator 2 and RF generator 4 switchable to RF3 COM, RF4 COM,
Output level range peak envelope power (PEP) the specified value is valid for the total
Output level uncertainty for each carrier see general technical specifications,
Signal-to-noise ratio for the carrier with the highest output level
RF analyzer 1 switchable to RF1 COM, RF2 COM see general technical specifications
Level uncertainty 70 MHz to 3300 MHz see general technical specifications,
Expected nominal power setting for full
dynamic range
Level range see general technical specifications,
®
CMW-S590D RF frontend (ADV.) and R&S®CMW-S570 RF TRX.
®
CMW-B590D RF frontend (ADV.) and:
- one R&S
- or three R&S
®
CMW-B570 RF TRX and two R&S®CMW-B571B RF TX
®
CMW-B570 RF TRX.
RF1 OUT
RF3 OUT
see general technical specifications,
see general technical specifications,
RF1 OUT
(at least 3 dB higher than the other carrier)
RF3 OUT
(at least 3 dB higher than the other carrier)
3300 MHz to 6000 MHz see general technical specifications,
see general technical specifications,
see general technical specifications
see general technical specifications
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
see general technical specifications
power of the two RF generators, see
general technical specifications
+ 0.2 dB
see general technical specifications
see general technical specifications
power of the two RF generators, see
general technical specifications
+ 0.2 dB
see general technical specifications
+ 0.2 dB
+ 0.3 dB
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
7
R&S®CMW500 only.
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 15
Version 11.00, May 2013
Configuration with four H570 (RF TRX) and two H590D (RF frontend (ADV.))
The three R&S®CMW-B570 options and R&S®CMW-B590D option make the four RF paths (RF path 1 RX and TX, RF path 2 RX and
TX, RF path 3 RX and TX, RF path 4 RX and TX) available on the front of the instrument at connectors RF1 COM, RF2 COM, RF1
OUT and RF3 COM, RF4 COM, RF3 OUT.
RF path 1, 2, 3 and 4 routed to separate connectors
RF generator 1 and RF generator 3 switchable to RF1 COM, RF2 COM,
RF1 OUT
RF generator 2 and RF generator 4 switchable to RF3 COM, RF4 COM,
RF3 OUT
RF analyzer 1 and RF analyzer 3 switchable to RF1 COM, RF2 COM see general technical specifications
Expected nominal power setting for full
see general technical specifications,
dynamic range
Level range see general technical specifications,
RF analyzer 2 and RF analyzer 4 switchable to RF3 COM, RF4 COM see general technical specifications
Expected nominal power setting for full
see general technical specifications,
dynamic range
Level range see general technical specifications,
RF path 1, RF path 3 routed to common connector and RF path 2, RF path 4 routed to common connector
RF generator 1 and RF generator 3 switchable to RF1 COM, RF2 COM,
RF1 OUT
Output level range peak envelope power (PEP) the specified value is valid for the total
Output level uncertainty for each carrier see general technical specifications,
Signal-to-noise ratio for the carrier with the highest output level
(at least 3 dB higher than the other carrier)
RF generator 2 and RF generator 4 switchable to RF3 COM, RF4 COM,
RF3 OUT
Output level range peak envelope power (PEP) the specified value is valid for the total
Output level uncertainty for each carrier see general technical specifications,
Signal-to-noise ratio for the carrier with the highest output level
(at least 3 dB higher than the other carrier)
RF analyzer 1 and RF analyzer 3 switchable to RF1 COM, RF2 COM see general technical specifications
Level uncertainty 70 MHz to 3300 MHz see general technical specifications,
3300 MHz to 6000 MHz see general technical specifications,
Expected nominal power setting for full
see general technical specifications,
dynamic range
Level range see general technical specifications,
RF analyzer 2 and RF analyzer 4 switchable to RF3 COM, RF4 COM see general technical specifications
Level uncertainty 70 MHz to 3300 MHz see general technical specifications,
3300 MHz to 6000 MHz see general technical specifications,
Expected nominal power setting for full
see general technical specifications,
dynamic range
Level range see general technical specifications,
see general technical specifications
see general technical specifications
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
see general technical specifications
power of the two RF generators, see
general technical specifications
+ 0.2 dB
see general technical specifications
see general technical specifications
power of the two RF generators, see
general technical specifications
+ 0.2 dB
see general technical specifications
+ 0.2 dB
+ 0.3 dB
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
+ 0.2 dB
+ 0.3 dB
+ 3 dB for lower level limit value
+ 3 dB (typ. + 2 dB) for lower level limit
value
16 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Timebase
–
–
–
–
–
–
–
–
–
–
Version 11.00, May 2013
Timebase TCXO
Max. frequency drift in temperature range +5 °C to +45 °C ±1 × 10
Max. aging at +25 °C,
±1 × 10
after 14 days of continuous operation
Timebase basic OCXO (R&S®CMW-B690A option)
Max. frequency drift in temperature range +5 °C to +45 °C ±5 × 10
Retrace at +25 °C,
±2 × 10
after 24 hours power on /
2 hours power off / 1 hour power on
Max. aging at +25 °C,
after 10 days of continuous operation
Warm-up time at +25 °C,
the frequency is in the range that is
10 times the frequency drift (±5 × 10
Measurement bandwidth 21 kHz
Frequency range 100 Hz to 10.5 kHz
Level range 10 mV to 30 V
Resolution 0.01 %
Inherent distortion THD+N at 100 mV ≤ level ≤ 20 V < 0.05 %
Inherent distortion THD at 100 mV ≤ level ≤ 20 V < 0.025 %
Uncertainty at 100 mV ≤ level ≤ 2 V < 1 % + inherent distortion
at 2 V ≤ level ≤ 20 V < 2 % + inherent distortion
Audio generator
Connectors AF 1 OUT / AF 2 OUT
Output impedance < 4 Ω
Maximum output current 20 mA
AF sine generator
Frequency range 20 Hz to 21 kHz
Frequency uncertainty same as time base ,
see base unit specifications
Frequency resolution 1 Hz
Level range 10 µV to 5 V
Level resolution at level < 10 mV 10 µV
at level ≥ 10 mV 0.1 %
Level uncertainty at level ≥ 1 mV and
frequency ≤ 10 kHz
THD+N at level ≥ 100 mV,
into load ≥ 600 Ω,
measurement bandwidth: 21.9 kHz
THD at level ≥ 100 mV,
into load ≥ 600 Ω,
measurement bandwidth: 21.9 kHz
≤ 1.5 % + resolution
≤ 0.05 %
≤ 0.025 %
®
18 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Digital interface unbalanced
BNC rear panel connectors
Connector SPDIF IN
Input impedance 75 Ω
Connector SPDIF OUT
Output impedance 75 Ω
Max. sample rate 48 kHz
Max. resolution 24 bits PCM
Output level 0.5 V, peak-to-peak
Max. output 0.6 V, peak-to-peak
Max. current 8 mA
Min input 0.2 V, peak-to-peak
Modulation biphase mark code
Usage audio analysis, digital audio tape (DAT)
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 19
Version 11.00, May 2013
GSM specifications – mobile station test 8
GSM RF generator
®
(prerequisite: R&S
Frequency range GSM450 band 460 MHz to 468 MHz
GSM GEN (R&S®CMW-KG200 option)
Output level range depending on PAR see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
Signal quality
Phase error GMSK < 1°, RMS
Error vector magnitude (EVM) 8PSK < 2 %, RMS
GSM WinIQSIM2™ (R&S®CMW-KW200 option), GSM EDGE EVO WinIQSIM2™
®
(R&S
CMW-KW201 option)
Arbitrary waveform files GMSK, B × T = 0.3, with the
Arbitrary waveform files 16QAM, with the R&S®CMW-KW200 and
Output level range depending on PAR see general technical specifications
Output level uncertainty with the R&S®CMW-KW200 option,
Output level resolution see general technical specifications
CMW-B110A/R&S®CMW-B110D option)
GSM480 band 488 MHz to 496 MHz
GSM750 band 747 MHz to 762 MHz
GSM850 band 869 MHz to 894 MHz
GSM900 band 921 MHz to 960 MHz
GSM1800 band 1805 MHz to 1880 MHz
GSM1900 band 1930 MHz to 1990 MHz
< 4°, peak
®
R&S
CMW-KW200 option
8PSK, with the R&S®CMW-KW200 option GSM_EDGE.WV (PAR = 3.23 dB),
®
R&S
CMW-KW201 options
32QAM, with the R&S®CMW-KW200 and
®
R&S
CMW-KW201 options
waveform files used:
GMSKDIGMOD.WV or
EDGEDIGMOD.WV
with the R&S®CMW-KW200 and
Level uncertainty bandpass, 900 kHz, RRC filter, α = 0.16 see general technical specifications
CMW-KM201 option)
GSM480 band 478 MHz to 486 MHz
GSM750 band 777 MHz to 792 MHz
GSM850 band 824 MHz to 849 MHz
GSM900 band 876 MHz to 915 MHz
GSM1800 band 1710 MHz to 1785 MHz
GSM1900 band 1850 MHz to 1910 MHz
8PSK, 16QAM (level A) windowed raised-cosine filter in line with
3GPP TS 45.005
9
The maximum permissible continuous power is +34 dBm due to thermal limits.
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 21
Version 11.00, May 2013
Power versus time measurement
Filter selectable Gaussian, 500 kHz or 1 MHz
Dynamic range filter → 500 kHz, Gaussian,
with fixed expected nominal power setting
GMSK > 72 dB, RMS
8PSK, 16QAM (level A) > 69 dB, RMS
Expected nominal power setting for full
dynamic range
Relative measurement uncertainty result > –40 dB typ. < 0.1 dB
Burst power measurement
Level range –50 dBm to +42 dBm 10
Level uncertainty filter → 500 kHz or 1 MHz, Gaussian see general technical specifications
RF1 COM, RF2 COM –8 dBm to +42 dBm 10
–60 dB ≤ result ≤ –40 dB typ. < 0.5 dB
Spectrum due to modulation measurement
Expected nominal power setting for full
dynamic range
Test method relative measurement, averaging
Filter Gaussian, 30 kHz, 5 pole
Measurement at an offset of ± 100/200/250/400/600/800/1000/1200/
Dynamic range offset ≥ 1200 kHz
RF1 COM, RF2 COM –8 dBm to +42 dBm 10
1400/1600/1800 kHz
GMSK > 74 dB
8PSK, 16QAM (level A) > 70 dB
Spectrum due to switching measurement
Expected nominal power setting for full
dynamic range
Test method absolute measurement, max. hold
Filter Gaussian, 30 kHz, 5 pole
Measurement at an offset of ± 400/600/1200/1800 kHz
GSM850 band, GSM900 band, GSM1800
band, GSM1900 band
Frequency setting channel number
Output level range depending on PAR and additional 6 dB
Output level resolution see general technical specifications
Output level uncertainty see general technical specifications
Modulation
Inherent phase error GMSK < 1°, RMS
The maximum permissible continuous power is +34 dBm due to thermal limits.
DL see GSM RF generator specifications
UL see GSM RF analyzer specifications
level margin
with DLDC: depending on PAR and
additional 9.3 dB level margin
see general technical specifications
see general technical specifications
< 4°, peak
22 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
WCDMA specifications – mobile station (UE) test 11
Standard 3GPP FDD
WCDMA RF generator
®
(prerequisite: R&S
Frequency range WCDMA band 1 2112.4 MHz to 2167.6 MHz
WCDMA GEN (R&S®CMW-KG400 option), WCDMA HSPA GEN (R&S®CMW-KG401 option)
Output level range depending on PAR see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
WCDMA band 2 1932.4 MHz to 1987.6 MHz
WCDMA band 3 1807.4 MHz to 1877.6 MHz
WCDMA band 4 2112.4 MHz to 2152.6 MHz
WCDMA band 5 871.4 MHz to 891.6 MHz
WCDMA band 6 877.4 MHz to 882.6 MHz
WCDMA band 7 2622.4 MHz to 2687.6 MHz
WCDMA band 8 927.4 MHz to 957.6 MHz
WCDMA band 9 1847.4 MHz to 1877.4 MHz
WCDMA band 10 2112.4 MHz to 2167.6 MHz
WCDMA band 11 1478.4 MHz to 1498.4 MHz
WCDMA band 12 730.4 MHz to 743.6 MHz
WCDMA band 13 748.4 MHz to 753.6 MHz
WCDMA band 14 760.4 MHz to 765.6 MHz
WCDMA band S 2182.4 MHz to 2197.6 MHz
WCDMA band S170 2180 MHz to 2190 MHz
WCDMA band S190 2190 MHz to 2200 MHz
Arbitrary waveform files with the R&S®CMW-KW400 option TM4CPICH.WV (PAR = 8.34 dB),
Output level range depending on PAR see general technical specifications
Output level uncertainty with the R&S®CMW-KW400 option,
Output level resolution see general technical specifications
®
CMW-KW403 option)
with the R&S®CMW-KW400 and
R&S
with the R&S®CMW-KW400 and
R&S
R&S
waveform file used:
3GPPDEFAULT.WV
with the R&S®CMW-KW401 option,
waveform file used:
WCDMA_DL_HSDPA.WV
with the R&S®CMW-KW402 option,
waveform file used:
WCDMA_DL_HSUPA.WV
with the R&S®CMW-KW400 and
R&S
R&S
R&S
waveform file used:
TM4CPICH.WV
composite EVM,
with the R&S
®
CMW-KW401 option,
< 2 %, RMS
waveform file used:
WCDMA_DL_HSDPA.WV
composite EVM,
with the R&S
®
CMW-KW402 option,
< 2 %, RMS
waveform file used:
WCDMA_DL_HSUPA.WV
with the R&S®CMW-KW400 and
®
R&S
CMW-KW401 and
®
R&S
CMW-KW402 and
®
R&S
CMW-KW403 options
< 2 %, RMS
WCDMA RF analyzer (R&S®CMW-KM400, R&S®CMW-KM401,
®
R&S
CMW-KM403 options)
Frequency range WCDMA band 1 1922.4 MHz to 1977.6 MHz
WCDMA band 2 1852.4 MHz to 1907.6 MHz
WCDMA band 3 1712.4 MHz to 1782.6 MHz
WCDMA band 4 1712.4 MHz to 1752.6 MHz
WCDMA band 5 826.4 MHz to 846.6 MHz
WCDMA band 6 832.4 MHz to 837.6 MHz
WCDMA band 7 2502.4 MHz to 2567.6 MHz
WCDMA band 8 882.4 MHz to 912.6 MHz
WCDMA band 9 1752.4 MHz to 1782.4 MHz
WCDMA band 10 1712.4 MHz to 1767.6 MHz
WCDMA band 11 1430.4 MHz to 1450.4 MHz
WCDMA band 12 700.4 MHz to 713.6 MHz
WCDMA band 13 779.4 MHz to 784.6 MHz
WCDMA band 14 790.4 MHz to 795.6 MHz
WCDMA band S 2002.4 MHz to 2017.6 MHz
WCDMA band S170 2010 MHz to 2020 MHz
WCDMA band S190 2000 MHz to 2010 MHz
Statistics
Statistical count 1 to 1000
Values current, average, minimum/maximum,
ME versus time, ME versus chip,
PE versus time, PE versus chip,
FE versus time,
UE versus time,
PS versus slot,
PD versus slot,
CDP versus slot,
CDE versus slot,
CD monitor
Error vector magnitude (EVM)
Measurement range up to 25 %, RMS
Inherent EVM < 2.5 %, RMS
Measurement length half-slot, 1 slot, multislot (1 to 120)
Frequency error
Measurement range ±3 kHz
Frequency measurement uncertainty
< 20 Hz + drift of timebase,
see general technical specifications
I/Q origin offset
Inherent I/Q offset for average ≥ 10 measurements < –55 dB
I/Q imbalance
Inherent I/Q imbalance < –50 dB
Spectrum measurements
Adjacent channel leakage ratio RMS detector
Filter 3.84 MHz, RRC, α = 0.22, WCDMA filter
Dynamic range first adjacent channel at ±5 MHz > 54 dB
second adjacent channel at ±10 MHz > 57 dB
Expected nominal power setting for full
RF1 COM, RF2 COM –4 dBm to +42 dBm 13
dynamic range
Uncertainty for –33 dBc first adjacent channel level < 0.5 dB
for –43 dBc second adjacent channel level < 0.5 dB
Measurement length 1 slot (2560 chip)
Power meter
UE power measurement RMS detector
Filter bandpass, 6.3 MHz, RRC, α = 0.22
Level range –55 dBm to +42 dBm 13
Level uncertainty see general technical specifications
Measurement length half-slot, 1 slot
13
The maximum permissible continuous power is +34 dBm due to thermal limits.
®
Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester 25
Version 11.00, May 2013
Off power measurement RMS detector
Filter 3.84 MHz, RRC, α = 0.22, WCDMA filter
Noise floor –72 dBm
Level uncertainty see general technical specifications +
Frequency range
Bands 1 to 14 with the R&S®CMW-KS400 option
DL see WCDMA RF generator specifications
UL see WCDMA RF analyzer specifications
Band S, band S170, band S190 with the R&S®CMW-KS400 and
Frequency setting channel number
Output level range depending on PAR see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
Output level setting total output power
Channel levels P-CPICH, P-SCH, S-SCH, P-CCPCH,
Signal quality
Error vector magnitude (EVM) global EVM for DL RMC in line with
®
R&S
CMW-KS425 options
DL see WCDMA RF generator specifications
UL see WCDMA RF analyzer specifications
PICH, DPCH, OCNS
3GPP TS 34.121 C3.1 to C3.4 with
DPCH/CPICH = 0 dB
E-UTRA band 1, FDD 2110 MHz to 2170 MHz
E-UTRA band 2, FDD 1930 MHz to 1990 MHz
E-UTRA band 3, FDD 1805 MHz to 1880 MHz
E-UTRA band 4, FDD 2110 MHz to 2155 MHz
E-UTRA band 5, FDD 869 MHz to 894 MHz
E-UTRA band 6, FDD 875 MHz to 885 MHz
E-UTRA band 7, FDD 2620 MHz to 2690 MHz
E-UTRA band 8, FDD 925 MHz to 960 MHz
E-UTRA band 9, FDD 1844.9 MHz to 1879.9 MHz
E-UTRA band 10, FDD 2110 MHz to 2170 MHz
E-UTRA band 11, FDD 1475.9 MHz to 1495.9 MHz
E-UTRA band 12, FDD 728 MHz to 746 MHz
E-UTRA band 13, FDD 746 MHz to 756 MHz
E-UTRA band 14, FDD 758 MHz to 768 MHz
E-UTRA band 15, FDD 2600 MHz to 2620 MHz
E-UTRA band 16, FDD 2585 MHz to 2600 MHz
E-UTRA band 17, FDD 734 MHz to 746 MHz
E-UTRA band 18, FDD 860 MHz to 875 MHz
E-UTRA band 19, FDD 875 MHz to 890 MHz
E-UTRA band 20, FDD 791 MHz to 821 MHz
E-UTRA band 21, FDD 1495.9 MHz to 1510.9 MHz
E-UTRA band 22, FDD,
prerequisite: R&S
®
CMW-KB036 option
3510 MHz to 3590 MHz
E-UTRA band 24, FDD 1525 MHz to 1559 MHz
E-UTRA band 25, FDD 1930 MHz to 1995 MHz
E-UTRA band 33, TDD 1900 MHz to 1920 MHz
E-UTRA band 34, TDD 2010 MHz to 2025 MHz
E-UTRA band 35, TDD 1850 MHz to 1910 MHz
E-UTRA band 36, TDD 1930 MHz to 1990 MHz
E-UTRA band 37, TDD 1910 MHz to 1930 MHz
E-UTRA band 38, TDD 2570 MHz to 2620 MHz
E-UTRA band 39, TDD 1880 MHz to 1920 MHz
E-UTRA band 40, TDD 2300 MHz to 2400 MHz
E-UTRA band 41, TDD 2496 MHz to 2690 MHz
E-UTRA band 42, TDD,
prerequisite: R&S
E-UTRA band 43, TDD,
prerequisite: R&S
Frequency range E-UTRA band 1, FDD 1920 MHz to 1980 MHz
E-UTRA band 2, FDD 1850 MHz to 1910 MHz
E-UTRA band 3, FDD 1710 MHz to 1785 MHz
E-UTRA band 4, FDD 1710 MHz to 1755 MHz
E-UTRA band 5, FDD 824 MHz to 849 MHz
E-UTRA band 6, FDD 830 MHz to 840 MHz
E-UTRA band 7, FDD 2500 MHz to 2570 MHz
E-UTRA band 8, FDD 880 MHz to 915 MHz
E-UTRA band 9, FDD 1749.9 MHz 1784.9 MHz
E-UTRA band 10, FDD 1710 MHz to 1770 MHz
E-UTRA band 11, FDD 1427.9 MHz to 1447.9 MHz
E-UTRA band 12, FDD 698 MHz to 716 MHz
E-UTRA band 13, FDD 777 MHz to 787 MHz
E-UTRA band 14, FDD 788 MHz to 798 MHz
E-UTRA band 15, FDD 1900 MHz to 1920 MHz
E-UTRA band 16, FDD 2010 MHz to 2025 MHz
E-UTRA band 17, FDD 704 MHz to 716 MHz
E-UTRA band 18, FDD 815 MHz to 830 MHz
E-UTRA band 19, FDD 830 MHz to 845 MHz
E-UTRA band 20, FDD 832 MHz to 862 MHz
E-UTRA band 21, FDD 1447.9 MHz to 1462.9 MHz
E-UTRA band 22, FDD,
prerequisite: R&S
E-UTRA band 24, FDD 1625.5 MHz to 1660.5 MHz
E-UTRA band 25, FDD 1850 MHz to 1915 MHz
Level setting manual mode
Statistics
Statistical count 1 to 1000
Values
®
CMW-KB036 option
3410 MHz to 3490 MHz
current, average, minimum/maximum,
standard deviation
28 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Trigger
Trigger source BASE: external TRIG A,
BASE: external TRIG B,
GPRF: BB generator,
LTE: free run (fast sync),
LTE: IF power
Power measurement
Slot power RMS detector
Level range –50 dBm to +30 dBm, RMS
Level uncertainty see general technical specifications
PCFICH, PHICH, PDCCH, PDSCH
UL RS (demodulation RS), PRACH, PUCCH,
PUSCH
Bandwidth 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz,
20 MHz
Modulation schemes DL PDSCH QPSK, 16QAM, 64QAM
UL PUSCH QPSK, 16QAM
Reference measurement channels RMCs in line with 3GPP TS 36.521
Annex A.2 (UL) and Annex A.3 (DL)
Frequency range
Bands 1 to 22 and bands 24 to 25 with the R&S®CMW-KS500 option
DL see LTE FDD RF generator specifications
UL see LTE FDD RF analyzer specifications
Frequency setting channel number
RMCs for FDD,
full and partial RB allocation,
modulation: QPSK, 16QAM,
64QAM (DL only)
DL signal
Output level range due to PAR 15 dB below max. output level of
RF generator,
see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution 0.1 dB
Output level setting in line with 3GPP TS 36.521 Annex C.0 RS energy per resource element (EPRE)
[dBm/15 kHz]
Channel levels PSS, SSS, PBCH, PCFICH, PHICH,
PDCCH, PDSCH
PHICH –30 dB to –12 dB relative to RS EPRE
Signal quality
Error vector magnitude (EVM) global EVM for cell with
bandwidth = 20 MHz
–30 dB to +0 dB relative to RS EPRE
< 2 %, RMS
17
R&S®CMW500 and R&S®CMW280 only.
®
32 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
LTE TDD RF analyzer (R&S®CMW-KM550 option)
Bandwidth 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz,
Frequency range E-UTRA band 33, TDD 1900 MHz to 1920 MHz
E-UTRA band 34, TDD 2010 MHz to 2025 MHz
E-UTRA band 35, TDD 1850 MHz to 1910 MHz
E-UTRA band 36, TDD 1930 MHz to 1990 MHz
E-UTRA band 37, TDD 1910 MHz to 1930 MHz
E-UTRA band 38, TDD 2570 MHz to 2620 MHz
E-UTRA band 39, TDD 1880 MHz to 1920 MHz
E-UTRA band 40, TDD 2300 MHz to 2400 MHz
E-UTRA band 41, TDD 2496 MHz to 2690 MHz
E-UTRA band 42, TDD,
prerequisite: R&S
E-UTRA band 43, TDD,
prerequisite: R&S
Level setting manual mode
Statistics
Statistical count 1 to 1000
Values
Trigger
Trigger source BASE: external TRIG A,
®
CMW-KB036 option
®
CMW-KB036 option
20 MHz
3400 MHz to 3600 MHz
3600 MHz to 3800 MHz
current, average, minimum/maximum,
standard deviation
BASE: external TRIG B,
GPRF: BB generator,
LTE: free run (fast sync),
LTE: IF power
Power measurement
Slot power RMS detector
Level range –50 dBm to +30 dBm, RMS
Level uncertainty see general technical specifications
For frequency error measurements relative to the downlink signal of the same R&S®CMW500, the uncertainty is in line with 3GPP TS 36.521-1 V9.3.0.
®
34 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
LTE TDD eNodeB RF analyzer (R&S®CMW-KN550 option)
Bandwidth 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15 MHz,
Frequency range E-UTRA band 33, TDD 1900 MHz to 1920 MHz
E-UTRA band 34, TDD 2010 MHz to 2025 MHz
E-UTRA band 35, TDD 1850 MHz to 1910 MHz
E-UTRA band 36, TDD 1930 MHz to 1990 MHz
E-UTRA band 37, TDD 1910 MHz to 1930 MHz
E-UTRA band 38, TDD 2570 MHz to 2620 MHz
E-UTRA band 39, TDD 1880 MHz to 1920 MHz
E-UTRA band 40, TDD 2300 MHz to 2400 MHz
E-UTRA band 41, TDD 2496 MHz to 2690 MHz
E-UTRA band 42, TDD,
prerequisite: R&S
E-UTRA band 43, TDD,
prerequisite: R&S
Level setting manual mode
Statistics
Statistical count 1 to 1000
Values
Trigger
Trigger source BASE: external TRIG A,
®
CMW-KB036 option
®
CMW-KB036 option
20 MHz
3400 MHz to 3600 MHz
3600 MHz to 3800 MHz
current, average, minimum/maximum,
standard deviation
BASE: external TRIG B,
GPRF: BB generator,
LTE: free run (fast sync),
LTE: IF power
Power measurement
Slot power RMS detector
Level range –50 dBm to +30 dBm, RMS
Level uncertainty see general technical specifications
numeric results and standard deviation burst power,
EVM all carriers,
EVM data carriers,
EVM pilot carriers,
center frequency error,
symbol clock error,
I/Q offset
graphical EVM versus symbol,
spectrum flatness,
I/Q constellation,
transmit spectrum mask
–18 dBm ≤ input level ≤ +42 dBm 33,
< –38 dB, RMS 35
RMS
< 35 Hz + drift of timebase,
for ≥ 100 symbol (400 µs)
see general technical specifications
bandwidth 20 MHz < 0.8 dB
bandwidth 40 MHz < 1.0 dB
bandwidth 80 MHz < 1.0 dB
Spectrum measurements
Transmit spectrum mask
Frequency span 320 MHz
Dynamic range in line with IEEE 802.11ac
Expected nominal power setting for full
dynamic range
33
The maximum permissible continuous power is +34 dBm due to thermal limits.
34
Measured with channel estimation based on payload.
35
3 dB less with R&S®CMW-H590D RF frontend (ADV.).
®
48 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
RF1 COM, RF2 COM
IEEE 802.11ac (5 GHz band) +12 dBm to +42 dBm 33
Version 11.00, May 2013
WLAN signaling access point emulator 36
®
(prerequisite: R&S
®
R&S
CMW-B270A options)
Standard IEEE 802.11a, g(OFDM), n
Physical layer mode OFDM
Frequency range WLAN IEEE 802.11n (2.4 GHz band),
Output level range
RF1 COM, RF2 COM 2.4 GHz band burst power (RMS) up to –16 dBm
RF1 OUT 2.4 GHz band burst power (RMS) up to –3 dBm
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
Modulation accuracy (EVM) 2.4 GHz band < –38 dB
Minimum input level RF1 COM, RF2 COM down to –40 dBm
Frequency measurement uncertainty < 10 Hz + drift of timebase,
see general technical specifications
37
Averaging across 100 bursts, UL: BW = 10 MHz, zone length = 18 symbols / 210 slots; DL: BW = 10 MHz, zone length = 34 symbols / 30 subchannels,
channel estimation = payload.
37
52 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Sample clock error
Measurement range –5 ppm to +5 ppm
Sample clock measurement uncertainty < 0.1 ppm
I/Q imbalance
Inherent I/Q gain imbalance < 0.1 dB
Inherent I/Q quadrature imbalance < 0.1°
Spectrum flatness, neighbor
Level uncertainty inner carriers/outer carriers < 0.5 dB
38
38
38
neighbor subcarriers < 0.1 dB
Spectrum measurements
Adjacent channel power RMS detector
Filter rectangle 5 MHz, 10 MHz
Dynamic range adjacent channels > 45 dB
Expected nominal power setting for full
dynamic range
Spectrum emission mask (SEM) RMS detector
Frequency span 60 MHz
Supported masks IEEE, WiMAX Forum®, TTA, user-defined
Dynamic range relative limit of IEEE mask > 50 dB
Expected nominal power setting for full
dynamic range
RF1 COM, RF2 COM > –3 dBm
RF1 COM, RF2 COM > –3 dBm
3.84 MHz or 7.68 MHz, RRC, α = 0.22,
WCDMA
WiMAX™ signaling base station emulator 39
®
(SISO prerequisite: R&S
®
R&S
CMW-B270A options,
MIMO prerequisite: R&S
®
R&S
CMW-B200A, R&S®CMW-B270A options)
Standard IEEE 802.16e
Physical layer mode OFDMA
Frequency range
WiMAX™ band 1, WiMAX™ band 2,
WiMAX™ band 3
Output level range
RF1 COM, RF2 COM, RF1 OUT peak envelope power (PEP) see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
Output level setting manual mode
Output level reference DL single data subcarrier power
CMW-KS700, R&S®CMW-B200A,
®
CMW-KS700, R&S®CMW-KS701, R&S®CMW-KS702,
DL see WiMAX™ RF generator specifications
UL see WiMAX™ RF analyzer specifications
preamble power up to –17.7 dBm 40 offset to peak envelope
power
single data subcarrier power up to –51.2 dBm 40 offset to peak envelope
power
38
Averaging across 100 bursts, UL: BW = 10 MHz, zone length = 18 symbols / 210 slots; DL: BW = 10 MHz, zone length = 34 symbols / 30 subchannels,
Measurement range graphically displayed, stop on limit fail 0 % to 100 %
Payload mode auto mode and user-defined mode region, data interval, payload size
Acknowledge type ARQ, HARQ, ping
Number of HARQ subbursts HARQ, ARQ in HARQ, ICMP in HARQ 2
Data DL All 0,
All 1,
bit pattern: 0101,
bit pattern: 1010,
pseudo random,
PN9 to PN23
Estimated BER ARQ, HARQ, ping
Physical parameters graphically displayed power,
frequency offset,
timing offset
Mobile capabilities MAC address,
Measurement reports reported from DUT RSSI, CINR (mean and SD), TX power
CQICH physical and effective CINR
Ranging control initial ranging, periodic ranging
Power control open loop, closed loop
Power boosting preamble, pilots, FCH, DL map, UL map,
Burst allocation mode data burst region optimized,
Bandwidth allocation mode data burst region dynamic,
Dummy burst generator unused symbols filled with pilots, dummy burst
Sample frequency offset −1000 Hz to +1000 Hz
AWGN CN ratio −6 dB to +40 dB, two channels
Trigger output WiMAX™ signaling: frame trigger
Service flows fragmentation control,
network entry completed,
waiting for CDMA RNG-RSP,
waiting for initial RNG-RSP,
waiting for SBC-RSP,
waiting for REG-RSP,
deregistered,
MS disconnected
idle mode,
cell reselection,
handover
configuration for advertisement
configuration
data and management bursts
normal
fixed
adjustable offset (positive and negative),
adjustable pulse width,
slope
UL ACK channel configuration
WiMAX™ IP application enabler (prerequisite: R&S®CMW-KA700,
®
R&S
CMW-B660, R&S®CMW-B661 options)
Key features throughput measurement and end-to-end
Interface rear panel 1 GBaseT
Convergence sublayer IP version V4
Protocols DHCP, RIP
DHCP support enable, disable (static IP)
Network settings WiMAX™ stack IP,
Interface to IP-based server/client
applications
Data throughput end-to-end IP connection
e.g. IPERF (throughput test),
DL: UDP, SISO up to 17.2 Mbps
DL: UDP, MIMO up to 36.5 Mbps
UL: UDP, SISO up to 9.7 Mbps
application testing
MS IP address (destination),
subnet mask,
gateway,
DNS server
e.g. web browsing,
e.g. FTP file transfer,
e.g. video streaming,
e.g. VoIP
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 55
Version 11.00, May 2013
TD-SCDMA specifications – mobile station (UE) test 41
Standard TD-SCDMA CWTS
TD-SCDMA RF generator
®
(prerequisite: R&S
Frequency range 42 TD-SCDMA band A
TD-SCDMA WinIQSIM2™ (R&S®CMW-KW750 option) and
TD-SCDMA ENH. WinIQSIM2™ (R&S
Arbitrary waveform files with the R&S®CMW-KW750 option TD-SCDMA_DEFAULT.WV
Output level range depending on PAR see general technical specifications
Output level uncertainty waveform file used:
Output level resolution see general technical specifications
Signal quality
Error vector magnitude (EVM) composite EVM,
CMW-B110A/R&S®CMW-B110D option)
channels 10054 to 10121 2010.8 MHz to 2024.2 MHz
TD-SCDMA band E
channels 11504 to 11996 2300.8 MHz to 2399.2 MHz
TD-SCDMA band F
channels 9404 to 9596 1880.8 MHz to 1919.2 MHz
®
CMW-KW751 option)
(PAR = 3.14 dB),
TD-SCDMA_PTWLOW.WV
(PAR = 2.67 dB)
with the R&S®CMW-KW750 and
®
R&S
CMW-KW751 options
TD-SCDMA_PTWLOW.WV
waveform file used:
TD-SCDMA_DEFAULT.WV
TD-SCDMA-DL_12K2.WV
(PAR = 5.41 dB)
see general technical specifications
< 4 %, RMS
TD-SCDMA RF analyzer (R&S®CMW-KM750 option)
Frequency range 42 TD-SCDMA band A
channels 10054 to 10121 2010.8 MHz to 2024.2 MHz
TD-SCDMA band E
channels 11504 to 11996 2300.8 MHz to 2399.2 MHz
TD-SCDMA band F
channels 9404 to 9596 1880.8 MHz to 1919.2 MHz
Statistics
Statistical count 1 to 1000
Values current, average, minimum/maximum,
Trigger
Trigger sources BASE: external TRIG A,
41
R&S®CMW500 and R&S®CMW280 only.
42
Bands A, E, F according to CCSA standard.
standard deviation
BASE: external TRIG B,
GPRF: BB generator,
TD-SCDMA: free run,
TD-SCDMA: IF power
56 Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Modulation analysis
Filter
Level range –28 dBm to +42 dBm 43
Analysis modes TD-SCDMA uplink QPSK, DPCH,
Measured parameters numeric results and standard deviation error vector magnitude (EVM),
graphical EVM versus time,
Error vector magnitude (EVM)
Measurement range up to 25 %, RMS
Inherent EVM < 2.5 %, RMS
Measurement length 1 slot, multislot (1 to 112)
Frequency error
Measurement range ±3 kHz
Frequency measurement uncertainty < 20 Hz + drift of timebase,
I/Q origin offset
Inherent I/Q offset for average ≥ 10 measurements < –55 dB
I/Q imbalance
Inherent I/Q imbalance < –50 dB
1.28 MHz, RRC, α = 0.22, TD-SCDMA
filter
QPSK, DPCH + HSDPA,
16QAM, DPCH + HSUPA
magnitude error (ME),
phase error (PE),
frequency error,
I/Q origin offset,
I/Q imbalance,
UE power
ME versus time,
PE versus time
see general technical specifications
Code domain
Filter
Level range –28 dBm to +42 dBm 43
Analysis modes TD-SCDMA uplink QPSK, DPCH,
Measured parameters numeric results and standard deviation code domain error (CDE)
graphical code domain power versus code
Code domain power versus code
Uncertainty < 0.4 dB
Measurement length 1 slot
Frequency range
Bands A, E, F with the R&S®CMW-KS750 option
DL see TD-SCDMA RF generator
UL see TD-SCDMA RF analyzer
Frequency setting channel number
Output level range P-CCPCH, depending on PAR see general technical specifications
Output level uncertainty P-CCPCH see general technical specifications
Output level resolution P-CCPCH see general technical specifications
Output level setting P-CCPCH total output power
Channel levels S-CCPCH, DwPCH, FPACH, PICH, DPCH –30 dB to +0 dB relative to total power
Signal quality
Error vector magnitude (EVM) global EVM for DL RMC in line with
3GPP TS 34.122 C3.1 to C3.4
4.75 kbps, 5.15 kbps, 5.9 kbps,
6.7 kbps, 7.4 kbps, 7.95 kbps 10.2 kbps,
12.2 kbps
specifications
specifications
< 2 %, RMS
44
The maximum permissible continuous power is +34 dBm due to thermal limits.
®
58 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
CDMA2000® 1xRTT specifications – mobile station test 45
Standard CDMA2000® standards TIA/EIA IS-2000 Rev. 0
CDMA2000® test standards TIA/EIA IS-98-F
Symbol rate 1.2288 Mcps
CDMA2000® 1xRTT RF generator
®
(prerequisite: R&S
Frequency range band class 0 860.025 MHz to 893.985 MHz
CDMA2000® GEN (R&S®CMW-KG800 option)
Output level range depending on PAR see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
Signal quality
Waveform quality (rho) > 0.99
CMW-B110A/R&S®CMW-B110D option)
band class 1 1930.000 MHz to 1990.000 MHz
band class 2 917.0125 MHz to 959.9875 MHz
band class 3 832.0125 MHz to 869.9875 MHz
band class 4 1840.000 MHz to 1870.000 MHz
band class 5 421.675 MHz to 493.480 MHz
band class 6 2110.000 MHz to 2169.950 MHz
band class 7 746.000 MHz to 764.000 MHz
band class 8 1805.000 MHz to 1879.950 MHz
band class 9 925.000 MHz to 958.750 MHz
band class 10 851.000 MHz to 939.975 MHz
band class 11 421.675 MHz to 493.475 MHz
band class 12 915.0125 MHz to 920.9875 MHz
band class 13 2620.000 MHz to 2690 MHz
band class 14 1930.000 MHz to 1995.000 MHz
band class 15 2110.000 MHz to 2155.000 MHz
band class 16 2624.000 MHz to 2690.000 MHz
band class 17 2624.000 MHz to 2690.000 MHz
band class 18 757.000 MHz to 769.000 MHz
band class 19 728.000 MHz to 746.000 MHz
CDMA2000® WinIQSIM2™ (R&S®CMW-KW800 option)
Arbitrary waveform files CDMA_OQPSK.WV (PAR = 5.54 dB) or
CDMA_HPSK.WV (PAR = 6.97 dB)
Output level range depending on PAR see general technical specifications
Output level uncertainty waveform file used:
Output level resolution see general technical specifications
Signal quality
Waveform quality (rho) waveform file used:
45
R&S®CMW500 and R&S®CMW280 only.
Rohde & Schwarz R&S
CDMA_OQPSK.WV or CDMA_HPSK.WV
CDMA_OQPSK.WV or CDMA_HPSK.WV
®
CMW500 Wideband Radio Communication Tester 59
see general technical specifications
> 0.99
Version 11.00, May 2013
CDMA2000® RF analyzer (R&S®CMW-KM800 option)
Frequency range band class 0 815.025 MHz to 848.985 MHz
band class 1 1850.000 MHz to 1910.000 MHz
band class 2 872.0125 MHz to 914.9875 MHz
band class 3 887.0125 MHz to 924.9875 MHz
band class 4 1750.000 MHz to 1780.000 MHz
band class 5 411.675 MHz to 483.480 MHz
band class 6 1920.000 MHz to 1979.950 MHz
band class 7 776.000 MHz to 794.000 MHz
band class 8 1710.000 MHz to 1784.950 MHz
band class 9 880.000 MHz to 913.750 MHz
band class 10 806.000 MHz to 900.975 MHz
band class 11 411.675 MHz to 483.475 MHz
band class 12 870.0125 MHz to 875.9875 MHz
band class 13 2500.000 MHz to 2570.000 MHz
band class 14 1850.000 MHz to 1915.000 MHz
band class 15 1710.000 MHz to 1755.000 MHz
band class 16 2502.000 MHz to 2568.000 MHz
band class 17 2502.000 MHz to 2567.950 MHz
band class 18 787.000 MHz to 700.000 MHz
band class 19 698.000 MHz to 716.000 MHz
Statistics
Statistical count 1 to 1000
Values current, average, minimum/maximum,
standard deviation
Trigger
Trigger sources BASE: external TRIG A,
BASE: external TRIG B,
GPRF: BB generator,
C2K: free run
Modulation analysis
Filter 1.23 MHz, RRC, α = 0.22, CDMA filter
Level range –28 dBm to +42 dBm 46
Analysis modes OQPSK, HPSK
Measured parameters numeric results and standard deviation error vector magnitude (EVM),
graphical EVM versus time,
Waveform quality (rho)
Uncertainty for rho 0.9 to 1 < 0.003
Measurement length 616 chip (0.5 ms)
Error vector magnitude (EVM)
Measurement range up to 25 %, RMS
Inherent EVM < 2.5 %, RMS
Measurement length 0.5 ms
magnitude error (ME),
phase error (PE),
frequency error,
rho,
carrier feedthrough,
I/Q imbalance,
power,
wideband power (8 MHz),
narrowband power (1.23 MHz)
ME versus time,
PE versus time
46
The maximum permissible continuous power is +34 dBm due to thermal limits.
®
60 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Frequency error
Measurement range ±3 kHz
Frequency measurement uncertainty < 20 Hz + drift of timebase,
see general technical specifications
Carrier feedthrough
Inherent carrier feedthrough for average ≥ 10 measurements < –55 dB
I/Q imbalance
Inherent I/Q imbalance < –50 dB
Code domain
Filter 1.23 MHz, RRC, α = 0.22, CDMA filter
Level range –28 dBm to +42 dBm 47
Measured parameters numeric values of current, average,
max. and min. values
graphical code domain power versus code,
Code domain power versus code
Uncertainty < 0.4 dB
Measurement length 616 chip (0.5 ms)
Code domain error versus code
Measurement uncertainty < 0.4 dB
Measurement length 616 chip (0.5 ms)
code domain power (CDP),
code domain error (CDE)
code domain error versus code
Spectrum measurements
Adjacent channel power RMS detector, at the selected frequency
offsets
Filter 30 kHz Gaussian
Frequency offset interval up to 10 adjacent channels on each side –4 MHz to +4 MHz
Dynamic range > 70 dB
Expected nominal power setting for full
RF1 COM, RF2 COM +1 dBm to +42 dBm 47
dynamic range
Uncertainty for –43 dBc adjacent channel level < 0.5 dB
Measurement length one power control group 1536 chip (1.25 ms)
Power meter
MS power
Filter narrowband bandpass, 1.25 MHz
Filter wideband bandpass, 8 MHz
Level range –55 dBm to +42 dBm
Level uncertainty see general technical specifications
Measurement length 616 chip (0.5 ms)
47
47
The maximum permissible continuous power is +34 dBm due to thermal limits.
Band class 0 to band class 19 DL see CDMA2000® 1xRTT RF generator
specifications
UL see CDMA2000® 1xRTT RF analyzer
specifications
Output level range depending on PAR see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
Modulation
Dual BPSK, multiple QPSK 1.2288 Mcps
Waveform quality (rho) > 0.99
Code channel level uncertainty relative to the total CDMA output power
Code channel resolution 0.1 dB
Code channel level range relative to the total CDMA output power
Supported service options
Loopback service options SO 2, 9, 55
Speech service options SO 1, 3, 17, 68, 0x8000
Speech codecs
Supported standards 8k (SO 1),
PICH, PCH, FCH, SCH0 approx. 0.1 dB
all other channels approx. 0.25 dB
PICH, PCH, FCH, SCH0, SYNC –20 dB to –1 dB
prerequisite: R&S
®
CMW-B405A options
R&S
CMW-B400B and
8k enhanced or EVRC-A (SO 3),
13k or QCELP (SO 17),
EVRC-B (SO 68),
EVRC-WB (SO 70),
EVRC-NW (SO 73)
®
62 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
CDMA2000® 1xEV-DO specifications – access terminal test 48
Standard CDMA2000® 1xEV-DO standards TIA/EIA 856-2
CDMA2000® 1xEV-DO test standards TIA/EIA 866-A, TIA/EIA 866-B
Symbol rate 1.2288 Mcps
CDMA2000® 1xEV-DO RF generator
®
(prerequisite: R&S
Frequency range band class 0 860.025 MHz to 893.985 MHz
Output level range depending on PAR see general technical specifications
Output level uncertainty waveform file used: EVDO_DEFAULT.WV see general technical specifications
Output level resolution see general technical specifications
band class 1 1930.000 MHz to 1990.000 MHz
band class 2 917.0125 MHz to 959.9875 MHz
band class 3 832.0125 MHz to 869.9875 MHz
band class 4 1840.000 MHz to 1870.000 MHz
band class 5 421.675 MHz to 493.480 MHz
band class 6 2110.000 MHz to 2169.950 MHz
band class 7 746.000 MHz to 764.000 MHz
band class 8 1805.000 MHz to 1879.950 MHz
band class 9 925.000 MHz to 958.750 MHz
band class 10 851.000 MHz to 939.975 MHz
band class 11 421.675 MHz to 493.475 MHz
band class 12 915.0125 MHz to 920.9875 MHz
band class 13 2620.000 MHz to 2690 MHz
band class 14 1930.000 MHz to 1995.000 MHz
band class 15 2110.000 MHz to 2155.000 MHz
band class 16 2624.000 MHz to 2690.000 MHz
band class 17 2624.000 MHz to 2690.000 MHz
band class 18 757.000 MHz to 769.000 MHz
band class 19 728.000 MHz to 746.000 MHz
Frequency range band class 0 815.025 MHz to 848.985 MHz
band class 1 1850.000 MHz to 1910.000 MHz
band class 2 872.0125 MHz to 914.9875 MHz
band class 3 887.0125 MHz to 924.9875 MHz
band class 4 1750.000 MHz to 1780.000 MHz
band class 5 411.675 MHz to 483.480 MHz
band class 6 1920.000 MHz to 1979.950 MHz
band class 7 776.000 MHz to 794.000 MHz
band class 8 1710.000 MHz to 1784.950 MHz
band class 9 880.000 MHz to 913.750 MHz
band class 10 806.000 MHz to 900.975 MHz
band class 11 411.675 MHz to 483.475 MHz
band class 12 870.0125 MHz to 875.9875 MHz
band class 13 2500.000 MHz to 2570.000 MHz
band class 14 1850.000 MHz to 1915.000 MHz
band class 15 1710.000 MHz to 1755.000 MHz
band class 16 2502.000 MHz to 2568.000 MHz
band class 17 2502.000 MHz to 2567.950 MHz
band class 18 787.000 MHz to 700.000 MHz
band class 19 698.000 MHz to 716.000 MHz
48
R&S®CMW500 and R&S®CMW280 only.
®
Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester 63
Version 11.00, May 2013
Statistics
Statistical count 1 to 1000
Values current, average, minimum/maximum,
standard deviation
Trigger
Trigger sources BASE: external TRIG A,
BASE: external TRIG B,
GPRF: BB generator,
1xEV-DO: free run
Modulation analysis
Filter 1.23 MHz, RRC, α = 0.22, CDMA filter
Level range –28 dBm to +42 dBm 49
Analysis modes dual BPSK
Multicarrier single carrier or 3 carriers within –8 MHz
Measured parameters numeric results and standard deviation error vector magnitude (EVM),
graphical EVM versus time,
Waveform quality (rho)
Uncertainty for rho 0.9 to 1 < 0.003
Measurement length half-slot 1024 chip (833.33 µs)
Error vector magnitude (EVM)
Measurement range up to 25 %, RMS
Inherent EVM < 2.5 %, RMS
Measurement length half-slot 1024 chip (833.33 µs)
Frequency error
Measurement range ±3 kHz
Frequency measurement uncertainty < 20 Hz + drift of timebase,
Carrier feedthrough
Inherent carrier feedthrough for average ≥ 10 measurements < –55 dB
I/Q imbalance
Inherent I/Q imbalance < –50 dB
to +8 MHz
magnitude error (ME),
phase error (PE),
frequency error,
rho,
carrier feedthrough,
I/Q imbalance,
power,
wideband power (8 MHz for single carrier
or 16 MHz for multicarrier),
narrowband power (1.23 MHz)
ME versus time,
PE versus time
see general technical specifications
49
The maximum permissible continuous power is +34 dBm due to thermal limits.
®
64 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Code domain
Filter 1.23 MHz, RRC, α = 0.22, CDMA filter
Level range –28 dBm to +42 dBm 50
Measured parameters numeric values of current, average,
max. and min. values
graphical code domain power versus code,
Code domain power versus code
Uncertainty < 0.4 dB
Measurement length half-slot 1024 chip (833.33 µs)
Code domain error versus code
Measurement uncertainty < 0.4 dB
Measurement length half-slot 1024 chip (833.33 µs)
code domain power (CDP),
code domain error (CDE)
code domain error versus code
Spectrum measurements
Adjacent channel power RMS detector, at the selected frequency
offsets
Filter 30 kHz Gaussian
Frequency offset interval up to 10 adjacent channels on each side –4 MHz to +4 MHz to each carrier
Dynamic range > 70 dB
Expected nominal power setting for full
dynamic range
Uncertainty for –43 dBc adjacent channel level < 0.5 dB
Measurement length half-slot 1024 chip (833.33 µs)
RF1 COM, RF2 COM +1 dBm to +42 dBm
50
Power meter
MS power
Filter narrowband bandpass, 1.25 MHz
Filter wideband bandpass, 8 MHz for single carrier or
16 MHz for multicarrier
Level range –55 dBm to +42 dBm 50
Level uncertainty see general technical specifications
Measurement length half-slot 1024 chip (833.33 µs)
Band class 0 to band class 19 DL see CDMA2000® 1xEV-DO RF generator
specifications
UL see CDMA2000® 1xEV-DO RF analyzer
specifications
Output level range depending on PAR see general technical specifications
Output level uncertainty see general technical specifications
Output level resolution see general technical specifications
The maximum permissible continuous power is +34 dBm due to thermal limits.
Rohde & Schwarz R&S
®
CMW500 Wideband Radio Communication Tester 65
Version 11.00, May 2013
Data application unit
®
(R&S
The R&S®CMW-B450A/R&S®CMW-B450B option provides data test capabilities and makes a Gigabit Ethernet connector available on
the rear of the instrument.
Data application
IP configuration IPv4 address configuration
File transfer protocol (FTP) FTP server
Hypertext transfer protocol (HTTP) HTTP server
Domain name service (DNS) DNS server
IP multimedia subsystem server (R&S®CMW-KAA20 option)
IMS server
VoIMS application, SMS application
Data application measurements (R&S®CMW-KM050 option)
Measured parameters ping,
IP impairments up to 7 filter rules,
CMW-B450A/R&S®CMW-B450B option) 51
IPv6 address configuration
FTP traffic generator
IMS registration,
voice over IMS,
SMS over IMS
IPerf,
IP throughput,
DNS requests,
IP logging
delay,
jitter,
packet loss,
packet corruption
IP analysis (R&S®CMW-KM051 option)
Measured parameters TCP analysis,
IP connectivity,
data amount per destination/protocol,
trigger per IP flow,
throughput per IP flow
LAN DAU interface
LAN DAU Ethernet RJ-45 connector, 1000 Mbps
51
R&S®CMW500 and R&S®CMW270 only.
®
66 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Digital I/Q 1 to 4 (R&S®CMW-B510F option) and
®
digital I/Q 5 to 8 (R&S
The R&S®CMW-B510F option makes the first digital I/Q interface and AUX interface and the R&S®CMW-B520F option makes the
second digital I/Q interface and AUX interface available on the rear of the instrument.
Digital I/Q interface
The digital I/Q interface can be used for connecting the R&S®CMW to the digital I/Q interface of other Rohde & Schwarz instruments
(e.g. R&S
DIG I/Q IN 1/3/5/7 input 26-pin MDR connector
Level LVDS
Clock rate in 100 MHz
Clock rate out 100 MHz
Control signals general-purpose control, for future use 6 signals 100 MHz
I/Q data
Resolution for clock rate up to 100 MHz 18 bit for I and 18 bit for Q
I/Q sample rate
Source internal, digital input, digital output,
Range 1.92 Msample/s to 100 Msample/s
Predefined values 53 standard-independent 100 Msample/s
I/Q enable/request rate
Digital input transfer mode 1 (enable mode) 75 MHz, 100 MHz
Digital output transfer mode 1 (enable mode) 100 MHz
®
AMU200A, R&S®EX-IQ-Box).
CMW-B520F option) 52
WCDMA, LTE 1.92 Msample/s, 3.84 Msample/s,
7.68 Msample/s, 9.6 Msample/s,
15.36 Msample/s, 19.2 Msample/s,
30.72 Msample/s
transfer mode 2 (request mode) 0 Hz to 100 MHz
transfer mode 2 (request mode) 0 Hz to 100 MHz
AUX interface
The AUX interface can be used for connecting the R&S®CMW to other instruments, e.g. to trigger, clock and enable signals.
AUX A/B/C/D bidirectional, half-duplex BNC connectors
Level 3.3 V TTL
Clock rate 0 Hz to 100 MHz
Included extras
Digital I/Q cable (two sets) same cable as included in R&S®SMU-Z6 26-pin MDR connector
52
R&S®CMW500 and R&S®CMW270 only.
53
Further values in the range from 400 sample/s to 100 Msample/s can be provided on request.
®
Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester 67
Version 11.00, May 2013
General data
RF connectors (front panel) Snap-N female, 50 Ω, compatible with
RF1 COM, RF2 COM combined RF input and RF output
RF1 OUT RF output
Remote control interfaces
(front panel)
54
LAN Ethernet RJ-45 connector, 100 Mbps
Remote control interfaces (rear panel)
IEEE 488 R&S®CMW-B612A IEEE bus (single)
interface option
R&S®CMW-B612B IEEE bus (dual)
interface option
54
LAN REMOTE Ethernet RJ-45 connector, 1000 Mbps
USB REMOTE 54 USB 2.0 type B connector
Further interfaces (front panel)
USB for keyboard, mouse, USB stick 3 × USB 2.0 type A connector
SENSOR for R&S®NRP-Zxx power sensors
DIGITAL MONITOR for external monitor,
only included in R&S
®
R&S
CMW-S600C or R&S®CMW-S600E
®
CMW-S600A or
configuration (front panel without display
or keypad)
Further interfaces (rear panel)
USB for keyboard, mouse, USB stick 2 × USB 2.0 type A connector
DVI for external monitor,
®
R&S
CMW-B620A DVI interface option
TRIG A, TRIG B trigger input/output 2 × BNC connector
International safety approvals VDE – Association for Electrical,
Electronic and Information Technologies
CSA – Canadian Standards Association CSAUL mark
N female connectors
IEC 60625-2 (IEEE 488.2),
24-pin Amphenol connector
2 × IEC 60625-2 (IEEE 488.2),
24-pin Amphenol connector
DVI-D connector
DVI-D connector
+40 °C, 80 % rel. humidity, steady state
applied harmonized standards:
• EN 61326-1 (industrial environment)
• EN 61326-2-1
• EN 55011 (class A)
applied harmonized standard:
EN 61010-1
• UL 61010-1 (second edition)
• CAN C22.2 No. 61010.1-04
GS mark
54
R&S®CMW500 and R&S®CMW270 only.
®
68 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
®
–
®
Mechanical resistance non-operating mode
Vibration sinusoidal in line with EN 60068-2-6,
5 Hz to 150 Hz, 0.15 mm amplitude const.,
55 Hz to 150 Hz, 0.5 g const.
Vibration random in line with EN 60068-2-64,
10 Hz to 300 Hz, acceleration 1.2 g RMS
Shock in line with MIL-STD-810E, method 516.4,
procedure I, 40 g shock spectrum
Power rating
Rated voltage 100 V to 240 V AC (± 10 %)
Rated frequency 50 Hz to 60 Hz (± 5 %)
Rated power max. 850 VA
standby max. 13 W
Power consumption R&S®CMW500 and R&S®CMW270
approx. 200 W
single tester, non-signaling
R&S®CMW280 single tester, non-signaling approx. 180 W
Display
selected with R&S
®
R&S
CMW-S600D or R&S®CMW-S600F
CMW-S600B or
configuration
(front panel with display and keypad)
Size 21 cm TFT color display (8.4")
Resolution 800 × 600 pixel (SVGA resolution)
Pixel failure rate < 1.1 × 10
5
Dimensions of the R&S
®
R&S
CMW270
CMW500 or
W × H × D, overall 465.1 mm × 197.3 mm × 517.0 mm
(18.31 in × 7.77 in × 20.35 in)
for rackmounting 19" 1/1, 4 HU, 450
Dimensions of the R&S®CMW280 W × H × D, overall 465.1 mm × 197.3 mm × 417.0 mm
(18.31 in × 7.77 in × 16.41 in)
for rackmounting 19" 1/1, 4 HU, 350
Weight of the R&S®CMW500 or
®
R&S
CMW270
single tester, non-signaling approx. 14 kg
(approx. 31 lb)
with typical options approx. 18 kg
(approx. 40 lb)
Weight of the R&S®CMW280 single tester, non-signaling approx. 12 kg
(approx. 27 lb)
with typical options approx. 14 kg
(approx. 31 lb)
Calibration interval 12 months recommended for highest accuracy,
see specified RF generator and
RF analyzer level uncertainty
24 months add 0.2 dB to specified RF generator and
RF analyzer level uncertainty
®
Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester 69
Version 11.00, May 2013
®
®
®
®
Ordering information
Designation Type Order No.
Wideband Radio Communication Tester
Base unit with following accessories:
power cord, operating manual (quick start guide), comprehensive
documentation on CD-ROM
Wireless Connectivity Tester
Base unit with following accessories:
power cord, operating manual (quick start guide), comprehensive
documentation on CD-ROM
Wideband Radio Communication Tester
Base unit with following accessories:
power cord, operating manual (quick start guide), comprehensive
documentation on CD-ROM
For more ordering information about available options, please see our product brochure (PD 5213.9211.12) or ask your local
Rohde & Schwarz expert to find the solution that is optimally suited to your needs.
Recommended extras for manual operation
For R&S®CMW-S600B or R&S®CMW-S600D or R&S®CMW-S600F configuration (front panel with display and keypad):
Designation Type Order No.
Mouse with USB Interface, optical R&S®PSL-Z10 1157.7060.04
For R&S
®
CMW-S600A or R&S®CMW-S600C or R&S®CMW-S600E configuration (front panel without display or keypad):
R&S
CMW500 1201.0002K50
R&S
CMW270 1201.0002K75
R&S
CMW280 1201.0002K25
Designation Type Order No.
Mouse with USB Interface, optical R&S®PSL-Z10 1157.7060.04
Keyboard with USB Interface (US assignment) R&S®PSL-Z2 1157.6870.04
17" TFT Monitor R&S®PMC3 1082.6004.12
Important information:
We recommend using only the above-mentioned original PC components from Rohde & Schwarz in connection with the
®
R&S
CMW500, R&S®CMW270 and R&S®CMW280. The interaction of all components is continuously tested.
Insufficiently shielded PC components may lead to EMC problems which may disturb RF measurements results.
Recommended extras
Designation Type Order No.
19" Rack Adapter R&S®ZZA-411 1096.3283.00
Digital Signal Interface Module R&S®EX-IQ-Box 55 1409.5505K04
Cable TVR 290, 26-pin MDR connector;
additional cable for R&S
e.g. R&S
®
AMU200A, R&S®EX-IQ-Box
®
CMW-B510F used with
R&S
SMU-Z6 55 1415.0201.02
55
R&S®CMW500 and R&S®CMW270 only.
®
70 Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester
Version 11.00, May 2013
Service options
Service options
Extended Warranty, one year R&S®WE1CMW Please contact your local
Extended Warranty, two years R&S®WE2CMW
Extended Warranty, three years R&S®WE3CMW
Extended Warranty, four years R&S®WE4CMW
Extended Warranty with Calibration Coverage, one year R&S®CW1CMW
Extended Warranty with Calibration Coverage, two years R&S®CW2CMW
Extended Warranty with Calibration Coverage, three years R&S®CW3CMW
Extended Warranty with Calibration Coverage, four years R&S®CW4CMW
Extended warranty with a term of one to four years (WE1 to WE4)
Repairs carried out during the contract term are free of charge
56
. Necessary calibration and adjustments carried out during repairs are
also covered. Simply contact the forwarding agent we name; your product will be picked up free of charge and returned to you in top
condition a couple of days later.
Extended warranty with calibration (CW1 to CW4)
Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your
Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs
calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades.
For product brochure, see PD 5213.9211.12 and www.rohde-schwarz.com
Rohde & Schwarz sales office.
56
and
56
Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included.
®
Rohde & Schwarz R&S
CMW500 Wideband Radio Communication Tester 71
Service you can rely on
5213
❙ Worldwide
❙ Local and personalized
❙ Customized and flexible
❙ Uncompromising quality
❙ Long-term dependability
About Rohde & Schwarz
Rohde & Schwarz is an independent group of companies
specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting,
radiomonitoring and radiolocation, as well as secure
communications. Established more than 75 years ago,
Rohde & Schwarz has a global presence and a dedicated
service network in over 70 countries. Company headquarters are in Munich, Germany.
Environmental commitment
❙ Energy-efcient products❙ Continuous improvement in environmental sustainability❙ ISO 14001-certied environmental management system
Cert ied Quali ty Syste m
ISO 9001
Rohde & Schwarz GmbH & Co. KG
www.rohde-schwarz.com
Regional contact
❙ Europe, Africa, Middle East | +49 89 4129 12345
customersupport@rohde-schwarz.com
❙ North America | 1 888 TEST RSA (1 888 837 87 72)