Atec CMA5000a User Manual

Data Sheet
CMA5000a OTDR Module Series
Optical Time Domain Reectometer
The CMA5000a Optical Time Domain Reectometer (OTDR) application is based on over 30 years of development and experience in characterizing optical bers. Our world – class OTDR modules continue this tradition with the latest in high performance hardware and dedicated, easy to use software.
The compact size of the OTDR application module allows another module (OTDR or test ber box) to be inserted into a small bay adapter and up to three more into a medium or large bay adapter.
Sophisticated analysis software provides consistent and accurate ber characterization
Dedicated testing modes simplify commonly performed tasks
Easy to use for any skill level – from fault location to advanced ber analysis
Touch screen and hard key user interfaces ensure smooth and efcient operation
Solutions for all network types: Metro, CWDM, ultra-long haul and FTTP deployments
Complete ber characterization from 10 available wavelengths
Automated, on-the-box reporting
High Performance Hardware
To satisfy even the most demanding testing requirements, the CMA5000a series OTDR modules, feature a multitude of available wavelengths including 1310 nm, 1550 nm, and 1625 nm. Up to three of these wavelengths can be combined into a single optical port providing full spectrum ber characterization at the press of a button and are ideal for testing backbone or metro networks that deploy CWDM. For ultra-long haul systems, the CMA5000a OTDR modules feature up to 50 dB of dynamic range (enough to see approximately 250 km of ber) – with an impressive 1 meter resolution.
Dedicated, Ease to Use Software
To simplify testing, the CMA5000a features dedicated testing modes to automate and simplify the task at hand. Fault Locate mode is designed for someone just starting out or the novice who only uses an OTDR occasionally. Simply connect the ber and press test. The unit will verify the ber is connected correctly, select testing parameters, execute the test and provide a text response indicating fault/break location and end to end loss.
Fault Locate Mode – ease to read results
For those who have more experience or would like to perform more advanced testing, Classic OTDR mode allows the user to select all parameters, compare up to eight traces and even generate splice loss reports.
Cable commissioning is also automated through the use of Construction OTDR mode where a wizard allows the user to select the required testing wavelengths, number of bers and le naming scheme. The wizard then becomes the project manager guiding the user through the testing and ensuring consistency with testing parameters and le naming – virtually eliminating user induced errors.
Construction OTDR – automated multi-ber testing
Added Value
To further increase the value of your CMA5000a OTDR, it can be equipped with an integrated power meter, a high output stabilized light source and integrated Visual Fault Locator (VFL). These
options are integrated into the single slot OTDR module and do not
require an additional module slot like some other solutions. In addition, all OTDR wavelengths are available as stabilized light sources reducing the equipment cost and providing a complete end-to-end loss testing solution. Whatever your testing needs, our world-class OTDR products are designed to reduce the time to install, commission and maintain ber spans.
2 Data Sheet
l
CMA5000a
Classic OTDR – advanced testing
Specications
Model
5225
5245
5246
Wavelength
1310 nm ±20 nm 1550 nm ±25 nm
1310 nm ±20 nm 1550 nm ±25 nm
1310 nm ±20 nm 1550 nm ±25 nm 1625 nm ±15 nm
1
Optical Fiber Type
Single Mode
(8 µm to 10 µm)
Pulse Width
2
5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000 ns
5, 10, 20, 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000, 30000 ns
Dynamic Range (typical) (SNR = 1)
37 dB 36 dB
43 dB 45 dB
43 dB 45 dB 43 dB
5254 1550 nm ±25 nm 50 dB 10 m 5 m
1: At 23°C, 10 µs pulse width
2: Range dependent
3: SNR = 1 with up to 256k averages (typical)
4: Deadzones measured on –45 dB reections
5: Using Bellcore TR-TSY-000196 Issue 2
Common Specications
Distance Range Sampling Resolution
1
1
5, 20, 50, 75, 125, 250, 300 km
0.125, 0.5, 1, 2, 4, 8, 16 m Sampling Points Up to 256,000 IOR Settings 1.300000 to 1.700000 Distance Measurement Accuracy Loss Measurement Accuracy (Linearity)
0.0025% of distance measurement ± distance resolution ± index uncertainty
±0.04 dB/dB
Loss Resolution 0.001 dB
Laser Safety
2
IEC 60825-1: 2007: CLASS 1 21CFR1040.10 Excludes deviations caused by conformance to Laser Notice No. 50 dated June 24, 2007
Optical Connector Universal with UFC, USC, UST, AFC, ASC
Fault Locate, Classic OTDR, Construction (Automated Multi-wavelength, Multi-fiber testing),
Operating Modes
Networks (data processing and report generation)
Optional: Power Meter, Stabilized Light Source, Visual Fault Locator (VFL), Video Inspection Probe (VIP) EMC EN61326-1, EN61000-3-2 LVD EN61010-1
1: Wavelength and range dependent
2: Safety measures for laser products
This product complies with optical safety standards in 21CFR1040.10 and IEC 60825-1; the following descriptive labels are afxed to the product.
Deadzone (typical)
3
(back-scattered)
9 m 9 m
10 m 10 m
10 m 10 m 10 m
Deadzone (typical)
4
(Fresnel)
4 m
3.5 m
5 m 5 m
6 m
5 m 5 m
5
Loss Test Set Option
Single mode (8 µm to 10 µm)
Laser (same wavelength and specs as OTDR) Stabilized
Light
Source
Type
Output –8 dBm (min.) Stability (at 23°C) ±0.2 dB (8 hours) Modes of Operation CW, 1 kHz, 2 kHz Connector Type Same as OTDR Detector Type InGaAs Wavelength Range 780 nm to 1800 nm Calibrated Wavelengths 850, 1300, 1310, 1490, 1550, 1625 nm
Power
Meter
Power Range Standard: –55 to +10 dBm, CATV: –45 to +20 dBm Resolution 0.01 dB, 0.01 W Accuracy ±4% (–50 to +5 dBm), ±8% (+5 to +10 dBm, –55 to –50 dBm) Linearity ±0.10 dB (–50 to +5 dBm) Connector Type Universal (uses LP-XX adapters) Wavelength 650 nm ±20 nm
Visual
Fault Locator
: Safety measures for laser products
This product complies with optical safety standards in 21CFR1040.10 and IEC 60825-1; the following descriptive labels are afxed to the product.
Output 0 dBm into 9 µm/125 µm fiber (max.) Transmission Modes CW, 2 Hz
Connector Type 2.5 mm universal
Laser Safety
IEC 60825-1: 2007: CLASS 3R
21CFR1040.10: CLASS II
Data Sheet
l
CMA5000a 3
Ordering Information
Please specify the model/order number, name and quantity when ordering.
The names listed in the chart below are Order Names. The actual name of the item may differ from the Order Name.
The CMA5200 OTDR’s are Single Bay modules that include one OTDR/Source Universal Adapter (UC-130-XX) at no charge. For units with a Power Meter option, a Meter Connector Adapter (LP-XX) is also included at no charge.
Additional OTDR modules are available in various combinations of wave lengths and dynamic ranges. Please contact Anritsu for a comprehensive list.
Module Number:
52 - - OTDR -
A B C
A = Select an OTDR Module
25 = Singlemode, 37/36 dB dynamic range, dual-wavelength 1310 nm/1550 nm 45 = Singlemode, 43/45 dB dynamic range, dual-wavelength 1310 nm/1550 nm 46 = Singlemode, 43/45/43 dB dynamic range, tri-wavelength 1310 nm/1550 nm/1625 nm 54 = Singlemode, 50 dB dynamic range, single-wavelength 1550 nm
B = Select Meter, Light Source and VFL Options
000 = No Meter, Light Source or VFL 001 = VFL Only 210 = +20 dBm Meter and Light Source 211 = +20 dBm Meter, Light Source and VFL
C = Select Connector
UFC = FC/UPC AFC = FC/APC USC = SC/UPC ASC = SC/APC UST = ST/UPC AST = ST/APC
United States
Anritsu Company
1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A. Toll Free: 1-800-267-4878 Phone: +1-972-644-1777 Fax: +1-972-671-1877
Canada
Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006
Brazil
Anritsu Eletrônica Ltda.
Praça Amadeu Amaral, 27 - 1 Andar 01327-010 - Bela Vista - São Paulo - SP - Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940
Mexico
Anritsu Company, S.A. de C.V.
Av. Ejército Nacional No. 579 Piso 9, Col. Granada 11520 México, D.F., México Phone: +52-55-1101-2370 Fax: +52-55-5254-3147
United Kingdom
Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582-731303
France
Anritsu S.A.
12 avenue du Québec, Bâtiment Iris 1- Silic 612, 91140 VILLEBON SUR YVETTE, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65
Germany
Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55
Printed on Recycled Paper
Italy
Anritsu S.r.l.
Via Elio Vittorini 129, 00144 Roma, Italy Phone: +39-6-509-9711 Fax: +39-6-502-2425
Sweden
Anritsu AB
Borgarfjordsgatan 13A, 164 40 KISTA, Sweden Phone: +46-8-534-707-00 Fax: +46-8-534-707-30
Finland
Anritsu AB
Teknobulevardi 3-5, FI-01530 VANTAA, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111
Denmark
Anritsu A/S (Service Assurance) Anritsu AB (Test & Measurement)
Kay Fiskers Plads 9, 2300 Copenhagen S, Denmark Phone: +45-7211-2200 Fax: +45-7211-2210
Russia
Anritsu EMEA Ltd. Representation Office in Russia
Tverskaya str. 16/2, bld. 1, 7th floor. Russia, 125009, Moscow Phone: +7-495-363-1694 Fax: +7-495-935-8962
United Arab Emirates
Anritsu EMEA Ltd. Dubai Liaison Office
P O Box 500413 - Dubai Internet City Al Thuraya Building, Tower 1, Suit 701, 7th Floor Dubai, United Arab Emirates Phone: +971-4-3670352 Fax: +971-4-3688460
India
Anritsu India Private Limited
2nd & 3rd Floor, #837/1, Binnamangla 1st Stage, Indiranagar, 100ft Road, Bangalore - 560038, India Phone: +91-80-4058-1300 Fax: +91-80-4058-1301
Catalog No. CMA5000a_OTDR-E-A-1-(1.00)
Specifications are subject to change without notice.
Singapore
Anritsu Pte. Ltd.
60 Alexandra Terrace, #02-08, The Comtech (Lobby A) Singapore 118502 Phone: +65-6282-2400 Fax: +65-6282-2533
P.R. China (Shanghai)
Anritsu (China) Co., Ltd.
Room 1715, Tower A CITY CENTER of Shanghai, No.100 Zunyi Road, Chang Ning District, Shanghai 200051, P.R. China Phone: +86-21-6237-0898 Fax: +86-21-6237-0899
P.R. China (Hong Kong)
Anritsu Company Ltd.
Unit 1006-7, 10/F., Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong, Phone: +852-2301-4980 Fax: +852-2301-3545
Japan
Anritsu Corporation
8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan Phone: +81-46-296-1221 Fax: +81-46-296-1238
Korea
Anritsu Corporation, Ltd.
502, 5FL H-Square N B/D, 681 Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400 Korea Phone: +82-31-696-7750 Fax: +82-31-696-7751
Australia
Anritsu Pty. Ltd.
Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255
Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817
P.R. China
Printed in Japan 10/APR/2013 ddcm
1209
Loading...