CDN 3063
AUTOMATED 3-PHASE
COUPLING/DECOUPLING NETWORK
The new, modular CDN 3063 continue Teseq’s philosophy of designing easily upgradeable test instru-
ments that maximize the users initial investment. Users can select a CDN from this series that fullls
their basic testing needs with the assurance that they can upgrade it to a model to t different generator
compatibility as their testing requirements change. The 3063 are designed for maximum reliability in a
wide range of test setups. Over temperature protection, which allows short term operation at currents
exceeding the nominal rating, prevents damage to internal components. The phase rotation indicator
in 3-phase units indicates a correctly sequenced power connection, preventing possible damage to
the EUT.
These fully automated IEC and ANSI compliant coupling networks fulll the new requirements for
EUT currents over 16 A in the surge standard IEC/EN 61000 -4-5:2005, as well special coupling modes and
3-phase models with broad cur-
rent range
Fully automated surge and burst
coupling
IEC and ANSI coupling methods
High accuracy switching tech-
nology
Phase rotation indicaton for safe
EUT operation
Modular and upgradeable to fit
new generator architecture
pulse amplitude control in the ANSI C62.45 standard, the ring wave pulse given in IEC/EN 61000 -4-12:2006
and the EFT in IEC/EN 61000-4-4 Ed. 2:2004.
The CDN 3063 couples surge and burst pulses into 1-, 2- or 3-phase power mains of up to 480 V with a
current range up to 32 A. This range incorporate the new IEC draft standard’s provision for testing EUT’s
with high power consumption. Reduced decoupling inductances in series with the EUT power connection
are specied in order to minimize series voltage losses. The draft standard denes three classes of lter
inductance for the following current ranges: up to 20 A, 20 to 60 A and 60 to 100 A.
The CDN 3063 in combination with the NSG 3060 completely fullls the unique coupling
requirements specied by ANSI C62.41. This standard requires a constant peak voltage amplitude
for any EUT mains voltage and phase angle. This can only be realized when the instantaneous EUT mains
power voltage at the selected phase angle is taken into account when the surge voltage is applied. The
instantaneous mains voltage must either be subtracted from or added to the surge generator setting
in order to keep the peak level constant with respect to ground (PE). Otherwise, the mains voltage is
summed with the surge pulse amplitude thereby increasing or decreasing the stress on the EUT from
the desired level.
To accomplish the unique ANSI C62.41 coupling methodology, the CDN 3063 utilizes the latest electronic
component technology to measure and track the mains voltage and simultaneously control the pulse
phase angle. This remarkable phase coupling accuracy can also be used for IEC coupling and exceeds
the existing standards requirements, and represents a signicant step forward in higher test results
reproducibility.
The CDN 3063 in combination with the NSG 3040 broaden the effectiveness of the generator extremely
and complete the generator usability for higher current level or 3-phase EUT application.
CDN 3063
AUTOMATED 3-PHASE
COUPLING/DECOUPLING NETWORK
Technical data coupling network
Dimensions/Weight
Parameter Value
CDN 3063-B32: Automated 3-phase coupling network for burst (EFT)
CDN 3063-S32: Automated 3-phase coupling network for surge (combination
wave, ring wave)
CDN 3063-C32: Automated 3-phase coupling net work for burst (EFT) and surge
(combination wave, ring wave)
Dimensions CDN 3063-C32: W: 449 mm (17.7”), H: 310.5 mm (12.25”, 7 HU), D: 565 mm (22.2”)
Weight CDN 3063-C32: 43 kg (94.8 lb) approx.
Electrical parameter
Parameter Value
Standards-compliant pulses: Electric fast transient EFT (burst) up to 4.8 kV
Combination wave up to 6.6 kV
Ring wave up to 6.6. kV
Decoupling attenuation: Residual pulse voltage on EUT power supply inputs; conforms to
IEC/EN 61000-4-5
Residual voltage on non-pulsed power supply inputs; conforms to
IEC/EN 61000-4-5
Instrument supply: 85 – 265 V
AC/DC EUT current range: 3 x 32 A continuous (over temperature protection)
3 x 40 A for approx. 35 min (over temparature protection)
3 x 50 A for approx. 10 min (over temperature protection)
EUT voltage range: 3-phase (5 wire) usable for 2-phase (4 wire) and 1-phase (3 wire)
EUT V
EUT V
EUT V
DC - 65 Hz with no EUT power loss, 40 0 Hz max. with EUT power
loss *(below 30 V synchronization not guaranteed, asynchronous
mode only)
Connections front panel: HV-surge pulse input from generator (Fischer connector)
EFT connector from generator (SHV connector)
Ground/PE connection
Connections rear panel: Connector for EUT supply, Phoenix screw terminals, phase rotation
detection
AC
30* to 480 V
AC
30* to 280 VAC rms, line to neutral, 50/60 Hz
AC
0 to 480 VDC
DC
rms, line to line
AC
Teseq AG
Nordstrasse 11F 4542 Luter bach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com www.teseq.com
691-261B October 2 009