Atec CDN User Manual

COUPLING / DECOUPLING NETWORK (CDN) CDN S TYPE
CDN USB/C, USB/P
Designed for IEC/EN 61000-4-6
USB/c for test central devises
USB/p for test periferal devises
IEC/EN 61000-4-6 specifi es the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specifi c to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).
Specially designed to test the universal serial bus, now common on most PCs, this CDN is fi tted with a USB plug (input and output) and can be used for up to 100 V and up to 1000 mA. Two different types are available as shown in the table below:
Technical specifications CDN USB/c, USB/p
CDN USB/c
Frequency range: 150 kHz to 230 MHz Power rating (EUT- and AE port) AC max. voltage (line to ground): 100 V DC max. voltage (line to ground): 100 V Current max : 1 A Test voltage: 200 V DC, 2 sec Common mode impedance (EUT port) 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω Coupling path (In/Out port/EUT) Connection: BNC 50 Ω RF voltage: <20 V Voltage division factor (RF input to EUT port) 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB Transmission bandwidth (wanted signal) EUT/AE B3 dB: > 80 MHz sin. (data pair balanced)
Product name
Line type Application Connector
EUT port
Connector AE port
CDN USB/c USB, screened USB for central devices USB “B“ type USB “A“ type
CDN USB/p USB, screened USB for peripheral
devices
USB “A“ type USB “B“ type
AE-side
EUT-side
CDN USB/c
100
150/50 adapter
CAL USB/c
RF out
Amp in
< +10 dBm
Amp out
ch.1 < +27 dBm
ch.2 < +20 dBm
ch.3 < +20 dBm
Power meter
NSG 4070
Power
USB
Tuning
StSizeStSize StSize
Local
Back
Stop
Run
Hold
0
.
1
4
7 8
5
2
3
kHz dBm
6
9
MHz dBµV
Hz V
Enter
Step
1
STO
FRQ
LVL
RCL
Step2Step
3
MOD
2nd
Help
RF
ON/OFF
Ground plane
6 dB Attenuator
No load or adapter required
Power meter with input impedance 50
Test generator e.g. Teseq NSG 4070 with built-in RF synthesizer,
brodband power amplifier and
power meter
AE-side
EUT-side
CDN USB/p
100
150/50 adapter
CAL USB/p
RF out
Amp in
< +10 dBm
Amp out
ch.1 < +27 dBm
ch.2 < +20 dBm
ch.3 < +20 dBm
Power meter
NSG 4070
Power
USB
Tuning
StSizeStSize StSize
Local
Back
Stop
Run
Hold
0
.
1
4
7 8
5
2
3
kHz dBm
6
9
MHz dBµV
Hz V
Enter
Step
1
STO
FRQ
LVL
RCL
Step2Step
3
MOD
2nd
Help
RF
ON/OFF
Ground plane
6 dB Attenuator
No load or adapter required
Power meter with input impedance 50
Test generator e.g. Teseq NSG 4070 with built-in RF synthesizer,
brodband power amplifier and
power meter
Test set-up calibration with CDN USB/p
Test set-up calibration with CDN USB/c
COUPLING / DECOUPLING NETWORK (CDN) CDN S TYPE
CDN USB/C, USB/P
Mechanical specifications
Size (W x H x D): 100 mm x 100 mm x 240 mm Weight: approx. 1.5 kg
Technical specifications
CDN USB/c, USB/p (continued)
Decoupling of CM disturbance (RF port / AE) 150 kHz: >60 dB
1.5 MHz: >60 dB 30 MHz: >50 dB 230 MHz: >40 dB