Atec BT User Manual

Benchtop Test Chambers
Temperature and Humidity
Compact chambers with extended testing ranges
ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they can be congured to accommodate your specic requirements. Their narrow footprint saves valuable lab space.
2
Benchtop Features
(°C)
Extreme temperatures possible
150°100°50°-50° 200°
BTZ & BTX
all models
BTU & BTL
all models
-70° 180°
-20° 180°
Temperature Comparison
BTZ-175: 5°C/m BTZ-133: 3.5°C/m
-100
-50
50
100
150
0
-70
180
30 600 90 120 150 180
min.
Models save valuable lab space
ESPEC introduces our expanded Criterion Series. With a narrower footprint and increased performance, these test chambers provide an economical and space-saving solution for cramped labs needing to do a variety of temperature (and humidity) testing.
All of the Criterion models have a 19.5 inch wide interior, which is 3.5 inches more than traditional benchtops, yet the exterior is 20% narrower. The four cubic foot models have the largest workspace found in a benchtop unit, while maintain­ing the smallest exterior footprint.
For additional space savings, the refrigeration system ven­tilates out the top, and utility connections are on the sides, thus allowing installation directly against a wall. With the elec­trical system behind the hinged control panel, minimal space allowance is required on the sides, as well.
Big chamber performance
The extended temperature ranges of the Criterion series make testing at extreme conditions possible without buying a larger, stand-alone chamber. Units are available that go as cold as -70°C.
Size Comparison
24"
12"
11"
15"
1.5 cu. ft. 4 cu. ft.
The Criterion series has two chamber sizes: 1.5 and 4 cubic feet. The interior width for both sizes is 19.5 inches. The exterior footprint for both sizes is the same, just 30" x 33.5".
Temperature Range Comparison
The four cubic foot models also offer a choice of humidity control. With a range from 10 to 95%, you can maximize your testing options. A low humidity system can extend this range even farther. (See humidity chart on page 7 for details.)
Faster temperature changes
The Criterion series can cycle temperatures at rates up to 5°C/minute without requiring liquid nitrogen. Signicant test time can be saved, as well as creating added thermal stress on your samples.
To demonstrate performance, ESPEC uses the international standard IEC 60068 3-5 measured at the supply air. Tem­perature cycles are run from hot to cold extremes, and the middle 80% of the transition is timed to determine perfor­mance. Your actual cycling results will vary depending on methodology, including the start and end temperatures, and the amount of samples loaded.
The BTZ & BTX models have extended cold temperature ranges without requiring liquid nitrogen. The BTU & BTL still offer sub-freezing testing capability.
Performance Comparison
The Criterion chambers respond quickly to setpoint changes. The BTZ-175 can save 30 minutes or more per cycle.
3