SPECIFICATIONS RATING/DESCRIPTION CONDITION
BHK-MG GENERAL (ENVIRONMENTAL) SPECIFICATIONS
SPECIFICATIONS RATING/DESCRIPTION CONDITION
Temperature Operating 0° to +50°C
Storage -20° to +75°C
Humidity 0 to 95% RH Non condensing
operating & storage
Shock 20g, 11msec ±50% Non operating, 3-axes
half sine 3 shocks each axis
Vibration 5-10Hz 10mm Non operating, 3-axes
double amplitude 1 hour each axis
Cooling Built-in fan, exhaust air to rear
Remote Error Sensing Provisions for 4-terminal (Kelvin)
(Default state is local sensing) connections to load
BHK-MG PHYSICAL CHARACTERISTICS
Dimensions
Weight
a-c source
connections
d-c output
terminals
Control
Digital display front panel
Output display
English
Metric
English
Metric
Front
Rear
Front
Rear
Local
Remote
5.22˝ x 8.35˝ x 15.9˝
133 x 212 x 404mm
26 lbs.
12 Kg
5.22˝ x 19˝ x 15˝
133 x 482.6 x 381mm
45 lbs.
20 Kg
Circuit breaker, 2-pole
Detachable IEC 3-wire type connector
interlock switch (200W only)
Jacks (2)
Terminal blocks (11 positions)
Voltage, current, mode, status, menu, program 2 x 16 character alphanumeric LCD, LED backlight
Interlock switch (200W)/proximity detector (40W)
protects rear connections
±Output
±Output, ±sense, ground,
grounding network, internal capacitor (-)
Excludes handles, feet and connectors
Unpacked
Digital control using front panel keypad
Digital control using rear panel IEEE 488 bus (24 pin female connector).
Analog control using two rear panel terminal strips (10 positions each) for voltage and current.
Output voltage is displayed with two decimals for 300 and 500V models and one decimal for 1000 and
2000V models. Output current for 200W (high current scale) and 40W (300V model) is displayed with
two decimals. 200W (low current scale) and all other 40W models are displayed with three decimals.
40W 200W
Kepco’s BHK-MG are high voltage
linear voltage-current stabilizers offered
in two sizes: a 40 watt half-rack design
and a 200 watt full-rack power supply.
Outputs range from 0-300 volts to
0-2000 volts. Both digital and analog
programming control is featured.
BHK-MG are CE marked per the Low
Voltage Directive (LVD), EN61010-1
and the EMC Directives.
FEATURES
• Two sizes: half-rack 40 watts,
full-rack 200 watts.
• FET output stage.
• Conventional filtering or fast response.
• Fast analog programming mode.
• Rapid recovery current mode in
fast mode.
• Local control from panel-mounted keypad.
• Built-in GPIB, IEEE 488.2, 12 bits.
• Support for SCPI language.
• 2-line 16 character LCD display.
• Full read back of voltage and current
on the bus.
• Increased resolution and accuracy (x10)
for reading small current.
• Versatile output on/off port (40W only).
• Extensive protection circuitry.