Atec AXOS User Manual

EXPANDABLE TEST SYSTEMS
www.haefely.com
a brand of
Haefely is a subsidiary
of Hubbell Incorporated.
2
AXOS SERIES
EMC IS ALL ABOUT STANDARDS.
The standards - are you really familiar with all of them? Whether people talk about generic standards
or product specic standards - stipulated by law or demanded from the manufacturer:
HAEFELY has integrated all of them.
Take benet from the most modern and easy to use conducted immunity test system ever
built. Welcome to the AXOS series.
Indoor applicances
Domestic Industrial Medical IT
White goods Robotics Monitoring Computers
Brown goods Welding machines Scanning Printers
Household Packing machines Analysing Modems
Lightning devices Production lines Pumps Hubs
Portable tools Laboratory
equipment
Home automation Servers
Outdoor applicances
Renewable energy Telecom Transportation Defense
Implants Phones
Solar panels Outdoor lines Automotive Component testing
Windmills Repeater Motorcycles Communications
Turbines Switching stations Trucks Vehicles
Inverters Data concentrators Electric vehicles Aircrafts
Infrastructure Telecommunication
centers
Charging stations Satellites
Expandable Test Systems
THE STANDARDS
IEC/EN 61000-4-5 Surge Combination Wave 1.2/50µs...8/20µs
Surge events can be generated by lightning phenomena, switching transients or the activation of protection devices in the power distribution system. A surge itself is inuenced by the propagation path taken so that impulses from the same event may have different forms depending upon where a measurement is taken. Combination Wave Generators (CWG) simulate a surge event in power lines close to or within buildings. Mostly the disturbances are tolerable because they are single events.
3
IEC/EN 61000-4-4 Electric Fast Transients, EFT/Burst
Industrial measurement and control equipment nearly always use conventional control units containing relays or other electro-mechanical switching devices. Fluorescent lamp ballast units, insufciently suppressed motors (hair dryers, vacuum cleaners, drills, etc.) are found everywhere in the public power supply. All of these are primarily inductive loads which generate interference when switched on or off. EFT events, can cause microprocessor units to malfunction or reset, with corresponding
disruption to normal operation.
IEC/EN 61000-4-11 Voltage Dips and Interrupts
Voltage failures occur following switching operations, short-circuits, response of fuses and when running up heavy loads. The quality of the electrical power supply is
increasingly becoming a central topic of discussion. The interference sources in the
mains, caused by electronic power control with non-linear components e.g. thyristors are used more frequently in domestic appliances such as hotplates, heating units, washing machines, television sets, economy lamps, PCs and industrial systems with speed-controlled drives.
IEC/EN 61000-4-9 Pulsed Magnetic Field
Under normal operating conditions, an AC current generates a steady magnetic eld so that equipment, such as monitors, close to AC power lines could suffer interference. Under fault conditions, a sudden high current level can result in a short duration ma­gnetic eld. Lightning strokes or short circuit fault currents in the power network can generate high level short duration magnetic elds.
4
AXOS SERIES
THE STANDARDS
IEC/EN 61000-4-12 Ring Wave / IEEE C62.41
Ring waves are used to simulate lightning or switching effects in domestic
single or three phase supplies within an adequately protected building.
The waveform has similar characteristics in both open and short circuit conditions. The ring wave is characterised as a bipolar damped oscillating wave.
IEC/EN 61000-4-5 Telecom Wave 10/700µs / ITU K.20, K.21, K.44, K.45
Telecommunication networks and lines are often disposed to lightning strikes and their associated effects. All telecommunication systems linked with lines in-
Expandable Test Systems
THE MODULAR CONCEPT
Welcome to the unique design and concept of modularity designed by HAEFELY.
HAEFELY is recognizing an increasing interest in testing departments to congure the required functions in compact immunity test systems more exible than ever. For that reason HAEFELY designed a unique concept of modularity which eviscerates large additional investments for customers in the future.
Moreover, constantly reduced product development times call for powerful, easy-to-
operate and ready-to-use conducted immunity test systems which can be expanded in
a multitude of different test applications. Customer requirements, particularly in the telecommunications and industrial electronics sector, emphasize a test system‘s ac­curacy and modularity, thus clearly pointing to easy to expand T&M equipment that is favourably priced and suitable for most of industries.
5
The new AXOS series has been tailored to exactly meet these requirements, offering special cost advantages for T&M applications in the development, production and servicing of telecommunications, components as well as safety and industrial electro-
nics.
All AXOS test systems come equipped with all the hardware needed for instant upgrades by only entering optional key codes into the licence code manager of the unit. After
entering the key code(s) the additional test functionalities like Surge Combination Wave, Ring Wave, Telecom Wave, EFT/Burst or Voltage Dips and Interrupts become available immediately. No direct intervention has to be done by the user at all.
License Manager of the AXOS series
6
AXOS SERIES
AXOS5 EXPANDABLE TEST SYSTEM
5
The new AXOS alone test systems into one single economic solution.
It can be individually combined either with 5 kV Surge Combination Wave, 5 kV EFT/Burst, Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and
UL standards.
expandable test system integrates all of the best features of several stand-
5
The AXOS
can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less fre-
quently users.
Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specic test environments.
All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS5 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well.
A wide range of cost-efcient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as
options.
AXOS5 front view
AXOS
5
rear view
OVERVIEW
FEATURES & BENEFITS
Easy to operate with manual and auto-
mated test modes, software assisted test preparation, pre-dened test rou­tines and visual aided test setups
Expandable Test Systems
STANDARDS
IEC/EN 61000-4-4 EFT / Burst
IEC/EN 61000-4-5 Surge Edition 2 & 3
7
Economic & Efcient
Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price
Safe and reliable operation by using
safety interlock, warning lamp and
emergency stop functions
Voltage and current monitoring of
surge impulses and EUT power pro-
vides valuable feedback to the test
engineer
Automatic generation of test report,
including test parameters, test setup
and test result
APPLICATIONS
IEC/EN 61000-4-9 Imp Magnetic Field
IEC/EN 61000-4-11
AC Dips and Interrupts
IEC/EN 61000-4-29
DC Dips and Interrupts
IEC/EN 61000-6-1 Generic Residential
IEC/EN 61000-6-2 Generic Industrial
IEC/EN 60335-1 Household
IEC/EN 60601-1 Medical
and many more
INDUSTRIES
Compliance & pre-compliance testing
of electrical products
CE marking
Product development and debugging
Compliance testing of telecom and
wireless devices
Industrial
Residential
Components
Medical
Renewable energy
Tele c o m
8
AXOS SERIES
TECHNICAL DATA - AXOS
GENERAL DATA
Control power
User test storage
Remote interface
Display
External trigger input
Trigger output
EUT failed input
Warning lamp output
85 V - 264 V 50/60 Hz
unlimited
Ethernet, RJ45
7“ / 800x480 / 24 bit
with touch-screen
5 V TTL
5 V TTL
5 V TTL
2 x 24 V / 1 A DC
5
Dimensions (W x H x D)
Weight
USB
AUX. interface
Synch input
External start / stop input
Analog output
Safety circuit
19“ / 4U (45 x 18 x 49 cm)
25 kg
for USB memory stick
D-sub 37p for external CDN, external trans-
former etc.
BNC, 10 V – 264 V AC
5 V TTL, starts / stops predened test se-
quence
0 – 10 V, for use with
external options
stops the test when unlocked
IEC / EN 61000-4-4 EDITION 2 & 3 EFT / BURST
Output voltage
Polarity
Output impedance
Rise time
Impulse duration
Burst mode
0.2 – 5.0 kV ±10%
at coaxial output
pos / neg / alternate
50 Ohm
5 ns ±30%
50 ns ±30% at 50 Ohm 50 ns –15 +100 ns at 1'000 Ohm
normal, continuous, real, random
Spike frequency
Burst duration
Burst period
Test time
Trigger
Integrated single phase coupling / decoupling network
1 Hz – 1 MHz
10 µs – 1 s
1 ms – 10 s
1 s– 1'000 minutes
automatic, manual,
external trigger input
264 V AC / 16 A 220 V DC / 10 A
Expandable Test Systems
IEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVE
Output voltage
Voltage rise time
Voltage duration
Polarity
Output impedance
Phase sync
Counter preselect
Counter
Peak voltage monitor
0.2 – 5.0 kV ±10%
1.2 µs ±30%
50 µs ±20%
postive / negative /
alternate
2 Ohm
0 – 359° with 1° steps or
asynchronous mode
1 – 1'000 / innite
100'000
BNC output: 1000:1 display: 3 digits
Output current
Current rise time
Current duration
Integrated single phase CDN
Impulse trigger
Peak current monitor
0.1 – 2.5 kA ±10%
8 µs ±20%
20 µs ±20%
264 V AC / 16 A 220 V DC / 10 A
automatic 2 s – 100 min
manual external trigger input
BNC output: 1 kA/V display: 3 digits
9
IEC / EN 61000-4-11 EDITION 2 AND IEC / EN 61000-4-29 DIPS & INTERRUPTS
Max. voltage
Max. current
Trigger
Interrupt dip level
RMS voltage monitor
264 V AC/DC
16 A AC/DC continuous 20 A for 5 s 23 A for 3 s 40 A for 3 s > 500 A inrush current
automatic manual external trigger input
0% 0% – 99% with external voltage source
BNC output: 100:1 display: 4 digits
Interrupt time
Interval time
Test time
Phase sync
RMS current monitor
0.5 period – 800 peri­ods
100 µs – 1000 minutes
1 period – 800 periods
synch
100 µs – 1000 minutes
asynch
1 s – 1000 minutes innite
0 – 359° 16 / 40 / 50 / 60 Hz
asynchronous mode
BNC output: 10 A/V display: 4 digits
10
AXOS SERIES
OVERVIEW OF AXOS5 SERIES
AXOS5 Compact Test System
Article no. 2490400
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
AXOS5
EFT/Burst Test System Article no. 2490402
AXOS5 Surge Test System
Article no. 2490401
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
AXOS5 Dips Test System
Article no. 2490403
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
Activated by default
Optionally available by activation via key code
*external voltage dips transformer "DIP 116" required **additional antenna coil "MSURGE-A" required
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
Expandable Test Systems
SCOPE OF SUPPLY - OPTIONS & ACCESSORIES
SCOPE OF SUPPLY
AXOS5 Compact Immunity Test System 2490400 AXOS5 Surge Test System 2490401 AXOS5 EFT/Burst Test System 2490402 AXOS5 Voltage Dips Test System 2490403
11
Qty. 1 Immunity Test System AXOS
5
Qty. 1 Mains Cable Qty. 1 User Manual Qty. 1 Certicate of Calibration
OPTIONS AND ACCESSORIES
FP-EFT 32M 3-Phase CDN EFT/Burst 32 A / 690 V 2490170 FP-EFT 100M2 3-Phase CDN EFT/Burst 100 A / 690 V 2495860 IP4A Capacitive Coupling Clamp for EFT/Burst 2491300
FP-SURGE 32A Automatic 3-Phase CDN Surge 32 A / 690 V 2490700 FP-SURGE 100M2 3-Phase CDN Surge 32A / 690 V 2490180
PCD 121 Symmetrical Data & Control Line Coupler 2498010 PCD 126A Asymmetrical Data & Control Line Coupler 2498030 DEC 5 Symmetrical Data & Control Line Decoupler 2490141 DEC 6 Symmetrical Data & Control Line Decoupler 2490151 DEC 7 Asymmetrical Data & Control Line Decoupler 2490161
DIP 116 Automatic Dips Transformer 16 A 40/70/80% 2490410
MSURGE-A Magnetic Field Test IEC / EN 61000-4-9 2490441
VTM 15000 Isolation Test 1.2/50 us up to 10 kV 2499960 VTM 15000/05 Isolation Test 1.2/50 us up to 10 kV / 0.5J 2499692
PDP 8000 HV Differential Probe 1000:1 for Surge 2499911 CP 101 Current Probe Model for Surge 2499931
ES External Emergency Stop Switch P12 4700751 WL External Warning Lamp P12 4700750
Calibration Accredited Calibration AXOS
Surge Key Code Key Code for Surge extension AXOS
EFT/Burst Key Code Key Code for EFT/Burst extension AXOS
Dips Key Code Key Code for Voltage Dips extension AXOS
5
5
5
5
2490420
470 0814
4700815
4700816
12
AXOS SERIES
AXOS8 EXPANDABLE TEST SYSTEM
The new AXOS8 expandable test system integrates all of the best features of several stand alone test systems into one single economic solution.
It can be individually combined either with 7 kV Surge Combination Wave, 7 kV Ring Wave, 7 kV Telecom Wave*, 5 kV EFT/Burst or Dips & Interrupts, along with an integrated single­phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, ITU, IEEE and UL standards.
The AXOS
from the PC. The easy to use menu together with the availability of predened test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specic test environments.
All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS8 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well.
A wide range of cost-efcient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.
8
can either be operated via front panel by large colour graphic interface or remotely
AXOS8 front view AXOS8 rear view
*external Telecom Wave Modul "TW8" required
OVERVIEW
Expandable Test Systems
13
FEATURES & BENEFITS
Easy to operate with manual and
automated test modes, software as­sisted test preparation, pre-dened test routines and visual aided test
setups
Economic & Efcient
Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price
Safe and reliable operation by using
safety interlock, warning lamp and
emergency stop functions
Voltage and current monitoring of
surge impulses and EUT power
provides valuable feedback to the
test engineer
Automatic generation of test report,
including test parameters, test setup
and test result
STANDARDS
IEC/EN 61000-4-4 EFT / Burst
IEC/EN 61000-4-5 Surge Edition 2 & 3
(1.2/50µs...8/20µs)
IEC/EN 61000-4-5 Surge (10/700µs)*
IEC/EN 61000-4-9 Magnetic Field**
IEC/EN 61000-4-11
AC Dips and Interrupts***
IEC/EN 61000-4-12 Ring Wave
IEC/EN 61000-4-29
DC Dips and Interrupts
IEC/EN 61000-6-1 Generic Residential
IEC/EN 61000-6-2 Generic Industrial
IEC/EN 60335-1 Household
IEC/EN 60601-1 Medical
IEC/EN 60950
APPLICATIONS
Compliance & pre-compliance testing
of electrical products
CE marking
Product development and debugging
Compliance testing of telecom and
wireless devices
Overtesting
* in combination with external Telecom Wave Modul "TW8" ** additional antenna coil "MSURGE-A" required *** external voltage dips transformer "DIP 116" required
EN 55024
IEEE C62.41
ITU K.20, K.21, K.44, K.45
14
AXOS SERIES
TECHNICAL DATA - AXOS
GENERAL DATA
Control power
User test storage
Remote interface
Display
External trigger input
Trigger output
EUT failed input
Warning lamp output
IEC / EN 61000-4-4 EDITION 2 & 3 EFT / BURST
Output voltage
Polarity
Output impedance
Rise time
Impulse duration
Burst mode
85 V - 264 V 50/60 Hz
unlimited
Ethernet, RJ45
7“ / 800x480 / 24 bit
with touch-screen
5 V TTL
5 V TTL
5 V TTL
2 x 24 V / 1 A DC
0.2 – 5.0 kV ±10% at
coaxial output
pos / neg / alternate
50 Ohms
5 ns ±30%
50 ns ±30% at 50
Ohm
50 ns –15 +100 ns at 1000 Ohm
normal, continuous, real, random
8
Dimensions (W x H x D)
Weight
USB
AUX. interface
Synch input
External start / stop input
Analog output
Safety circuit
Spike frequency
Burst duration
Burst period
Test time
Trigger
Integrated single phase coupling / decoupling network
22“ / 6U (45 x 27 x 50 cm)
30 kg
for USB memory stick
D-sub 37p for external CDN, external trans-
former etc.
BNC, 10 V – 264 V AC
5 V TTL, starts / stops predened test se-
quence
0 – 10 V, for use with
external options
stops the test when unlocked
1 Hz – 1 MHz
10 us – 1 s
1 ms – 10 s
1 s– 1000 minutes
automatic, manual,
external trigger input
264 V AC / 16 A 220 V DC / 10 A
IEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVE
Output voltage
Voltage rise time
Voltage duration
Polarity
Output impedance
Phase sync
Counter preselect
Counter
Peak voltage monitor
0.2 – 7.0 kV ±10%
1.2 us ±30%
50 us ±20%
pos / neg / alternate
2 Ohms
0 – 359° with 1° steps
or asynchronous mode
1 – 1000 / innite
100000
BNC output: 1000:1 display: 3 digits
Output current
Current rise time
Current duration
Integrated single phase CDN
Impulse trigger
Peak current monitor
0.1 – 3.5 kA ±10%
8 us ±20%
20 us ±20%
264 V AC / 16 A 220 V DC / 10 A
automatic 2 s – 100 min
manual external trigger input
BNC output: 1 kA/V display: 3 digits
IEC / EN 61000-4-5 Telecom Wave / ITU K.20, K.21, K.44, K.45
Max. voltage
Front time OC
Decay time OC
Undershoot OC
Front time SC
Decay time SC
Undershoot SC
Polarity
0.2 - 7.0 kV ± 10%
10 µs ± 30%
700 µs ± 20%
< 30%
5 µs ± 20%
320 µs ± 20%
< 30%
Positive / negative /
alternate
Source impedance / coupling
Outputs
Impulse output
Impulse input
Transitions
Number of events
Repetition rate
Weight
Expandable Immunity Test Systems
15 Ohm 40 Ohm 40 Ohm gas arresters
1 x 15 Ohm direct 4 x 40 Ohm direct 4 x 40 Ohm gas arresters
Banana connector
HV connector
V, Polarity
1 - 10'000
up to 30 / min.
10 kg
15
IEC / EN 61000-4-11 EDITION 2 AND IEC / EN 61000-4-29 DIPS & INTERRUPTS
Max. voltage
Max. current
Trigger
Interrupt dip level
RMS voltage monitor
264 V AC/DC
16 A AC/DC continuous 20 A for 5 s 23 A for 3 s 40 A for 3 s > 500 A inrush current
automatic manual external trigger input
0% 0% – 99% with external voltage source
BNC output: 100:1 display: 4 digits
Interrupt time
Interval time
Test time
Phase sync
RMS current monitor
IEC / EN 61000-4-12 AND IEEE C62.41 Ring Wave
Max. voltage
Frequency
Rise time OC
Rise time SC
Impedance
0.2 - 7.0 kV ± 10%
100 kHz
0.5 µs
1 µs
12 Ohm, 30 Ohm
Repetition rate
Polarity
Floating output
Phase sync accuracy
Damping rate
0.5 period – 800 periods 100 µs – 1000 minutes
1 period – 800 periods
synch
100 µs – 1000 minutes
asynch
1 s – 1000 minutes innite
0 – 359° 16 / 40 / 50 / 60 Hz
asynchronous mode
BNC output: 10 A/V display: 4 digits
Up to 30 pulses / min
Positive / negative /
alternate
Max. 460 V / AC
± 1°
60% of previous peak
16
AXOS SERIES
OVERVIEW OF AXOS8 SERIES
AXOS8 Compact Test System
Article no. 2490800
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU
Ring Wave IEEE C62.41
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
AXOS8 Surge Test System
Article no. 2490810
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU
Ring Wave IEEE C62.41
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
AXOS8 Dips Test System
Article no. 2490840
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU
Ring Wave IEEE C62.41
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
AXOS8
EFT/Burst Test System Article no. 2490830
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU
Ring Wave IEEE C62.41
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
* in combination with external Telecom Wave Modul "TW8" ** external voltage dips transformer "DIP 116" required *** additional antenna coil "MSURGE-A" required
Expandable Test Systems
17
AXOS8
Ring Wave Test System Article no. 2490820
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU
Ring Wave IEEE C62.41
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
AXOS8
Telecom Wave System Article no. 2490850
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5
Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU
Ring Wave IEEE C62.41
EFT/Burst IEC/EN 61000-4-4
Voltage Dips
IEC/EN 61000-4-11*
Magnetic Field
IEC/EN 61000-4-9**
Activated by default
Optionally available by activation via key code
* in combination with external Telecom Wave Modul "TW8" ** external voltage dips transformer "DIP 116" required *** additional antenna coil "MSURGE-A" required
18
AXOS SERIES
SCOPE OF SUPPLY - OPTIONS & ACCESSORIES
SCOPE OF SUPPLY
AXOS8 Compact Immunity Test System 2490800 AXOS8 Surge Test System 2490810 AXOS8 EFT/Burst Test System 2490830 AXOS8 Voltage Dips Test System 2490840 AXOS8 Ring Wave Test System 2490820 AXOS8 Telecom Wave Test System 2490850
Qty. 1 Immunity Test System AXOS Qty. 1 Telecom Wave Modul "TS 8" 10/700µs* Qty. 1 Mains Cable Qty. 1 User Manual Qty. 1 Certicate of Calibration
OPTIONS AND ACCESSORIES
FP-EFT 32M 3-Phase CDN EFT/Burst 32 A / 690 V 2490170 FP-EFT 100M2 3-Phase CDN EFT/Burst 100 A / 690 V 2495860 IP4A Capacitive Coupling Clamp for EFT/Burst 2491300
FP-SURGE 32A Automatic 3-Phase CDN Surge 32 A / 690 V 2490700 FP-SURGE 100M2 3-Phase CDN Surge 32A / 690 V 2490180
TW 8 Telecom Wave Modul 10/700µs 4700915
PCD 121 Symmetrical Data & Control Line Coupler 2498010 PCD 126A Asymmetrical Data & Control Line Coupler 2498030 DEC 5 Symmetrical Data & Control Line Decoupler 2490141 DEC 6 Symmetrical Data & Control Line Decoupler 2490151 DEC 7 Asymmetrical Data & Control Line Decoupler 2490161
8
DIP 116 Automatic Dips Transformer 16 A 40/70/80% 2490410
MSURGE-A Magnetic Field Test IEC / EN 61000-4-9 2490441
VTM 15000 Isolation Test 1.2/50 us up to 10 kV 2499960 VTM 15000/05 Isolation Test 1.2/50 us up to 10 kV / 0.5J 2499692
PDP 8000 HV Differential Probe 1000:1 for Surge 2499911 CP 101 Current Probe Model for Surge 2499931
ES External Emergency Stop Switch P12 4700751 WL External Warning Lamp P12 4700750
* only with AXOS8 Telecom Wave Test System (2490850)
Expandable Test Systems
OPTIONS AND ACCESSORIES
Surge Key Code Key Code for Surge extension AXOS8 4 700 911
19
EFT/Burst Key Code Key Code for EFT/Burst extension AXOS
Ring Wave Key Code Key Code for Ring Wave extension AXOS
8
8
Dips Key Code Key Code for Voltage Dips extension AXOS
VALUE ADDED SERVICES
Pre- & After Sales Support
Application Support
Commissioning
Warranty Extension
Calibration (accredited & factory)
Training and Seminars
4700 912
4700913
8
470 0914
Rental units
Headquarters China (Sales & Service Ofce) North American Ofce
Haefely Test AG HAEFELY Representative Ofce Hipotronics Inc. Birsstrasse 300 8-1-602, Fortune Street Haefely EMC Division 4052 Basel No.67, Chaoyang Road, Chaoyang District 1650 Route 22 Switzerland Beijing, China 100025 Brewster, NY 10509
+ 41 61 373 41 11 +86 10 8578 8099 +1 845 279 3644 + 41 61 373 49 12 +86 10 8578 9908 +1 845 279 2467
emcsales@haefely.com sales@haefely.com.cn emcsales@hubbell-haefely.com
March 2013
Loading...