Atec Agilent-8163A, Agilent-81634A User Manual

For more information about
Agilent Technologies test and measurement
products, applications, services, and for a
current sales office listing, visit our web site:
You can also contact one of the following
centers and ask for a test and measurement
sales representative.
United States:
Agilent Technologies Test and Measurement Call Center P.O. Box 4026 Englewood, CO 80155-4026 (tel) 1 800 452 4844
Canada:
Agilent Technologies Canada Inc. 5150 Spectrum Way Mississauga, Ontario L4W 5G1 (tel) 1 877 894 4414
Europe:
Agilent Technologies Test & Measurement European Marketing Organisation P.O. Box 999 1180 AZ Amstelveen The Netherlands (tel) (31 20) 547 9999
www.agilent.com/comms/lightwave
Japan:
Agilent Technologies Japan Ltd. Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi, Tokyo 192-8510, Japan (tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Latin America:
Agilent Technologies Latin American Region Headquarters 5200 Blue Lagoon Drive, Suite #950 Miami, Florida 33126 U.S.A. (tel) (305) 267 4245 (fax) (305) 267 4286
Australia/New Zealand:
Agilent Technologies Australia Pty Ltd
347 Burwood Highway
Forest Hill, Victoria 3131 (tel) 1-800 629 485 (Australia) (fax) (61 3) 9272 0749 (tel) 0 800 738 378 (New Zealand) (fax) (64 4) 802 6881
Related Agilent Literature
8163A Lightwave Multimeter Ordering Guide, p/n 5968-3582E
8163A Lightwave Multimeter Technical Specifications, p/n 5962-9321E
8163A Lightwave Multimeter Configuration Guide, p/n 5968-3581E
Technical data is subject to change Copyright © 1999 Agilent Technologies Printed in Germany 12/99 (B.O.L.A.Y. GmbH) P/N 5968-3404E
Asia Pacific:
Agilent Technologies 24/F, Cityplaza One, 1111 King’s Road, Taikoo Shing, Hong Kong (tel) (852)-3197-7777 (fax) (852)-2506-9284
“Working together
should be a standard.”
Agilent 8163A
Lightwave Multimeter
Product Overview
• precise
• reliable
• fast
www.agilent.com/comms/lightwave
The New Standard Features and Benefits
The Agilent 8163A Lightwave Multi­meter is a basic measurement tool in the fiber optic industry. It ensures accurate and fast results, even for your most demanding measurements on optical components and systems.
The 8163A Lightwave Multimeter is the successor to the highly popular 8153A Lightwave Multimeter. It builds on all the key attributes that made the 8153A Lightwave Multimeter the standard in Research and Development and in Manufacturing.
Its modular format makes it flexible enough to meet your changing mea­surement needs, whether you are measuring optical power, insertion loss or return loss for single- or multimode components.
The lightwave multimeter system includes the mainframe and a variety of plug-in modules for set-ups requiring:
• single or dual channel power
meters,
• single or dual fixed light
High Bandwidth
sources,
• compact tunable laser modules
The 8163A Lightwave Multimeter helps ease your work-load by offering several advanced functions that turn your 8163A into a powerful measure­ment system.
Without needing an external controller, built-in application software guides you through the step-by-step proce­dures needed for measurement tasks such as measuring loss, monitoring stability or logging data.
For example, for long term monitoring you only need to input the total mea­surement time and the averaging time per sample – the 8163A Lightwave Multimeter does the rest. After the test is complete, the result can be displayed numerically or graphically on the display or the result can be sent to a printer.
You can easily integrate the 8163A Lightwave Multimeter into your test environment by using plug & play drivers over GPIB, or by using the configurable hardware input and out­put trigger ports.
“The Agilent family of
optical component test equipment. Because working
High Bandwidth
together should be a standard.”
Best possible measurement results
Precise, sensitive, stable and fast power measurements
You can be sure of the best possible measurement results thanks to the excellent accuracy, high linearity and low polarization dependent loss (PDL) of our full range of power sensors and optical heads.
To meet your test requirements, our range of sensors and heads cover the important wavelengths and power ranges you need. And you will like the measurement speed which can come down to 100 µs. A broad variety of advanced interfaces and adapters makes it easy to connect your test devices.
Measurements requiring a stable fixed source
To take the uncertainty out of moni­toring loss over long periods of time, Agilent’s sources are stabilized and very insensitive to backreflections.
For your convenience there are single and dual wavelength source modules, available with an output power of up to +13 dBm. The output power of the sources can be attenuated for applica­tions where you need lower power levels.
Measurements requiring a tunable source
If you need to make measurements at various fixed wavelengths, or if the test device must be characterized as a function of wavelength, then the compact tunable laser module is the ideal candidate for your test needs.
In combination with a power sensor or an optical head you can setup a complete measurement system for wavelength dependent loss.
To help you work efficiently and quick­ly and to increase your throughput and yield, the input ports are desi­gned to eliminate multiple reflections – the cause of many measurement errors.
DWDM
DWDM
The Agilent 8163A Lightwave Multimeter allows engineers to count on the accuracy of their measurements more than ever.
Upgradable Firmware
Compatibility
To protect your investment for the future, the Agilent 8163A Lightwave Multimeter is designed for easy firm­ware upgrades as new modules and features become available.
To protect your existing investment the 8163A main­frame is compatible with the modules from the 8153A Lightwave Multimeter series.
Also you can use both the modules of the 8163A and 8153A series together in the 8163A Lightwave Multimeter Mainframe.
The programming syntax used by the 8163A Multimeter mainframe is compatible with the 8164A Lightwave Measurement System (the tunable laser family), the 8166A Lightwave Multichannel System and with the 8153A Lightwave Multimeter.
The 8163A mainframe is compatible in height and width with the 8153A series, making it easy for you to add or substitute the 8163A to your rack systems.
“Working together
should be a standard.”
Flexible enough to meet changing measurement needs.
High Precision
High Precision
Selected Specifications
8163A Lightwave Multimeter
1)
Display: Graphical display,
monochrome
Programming*: SCPI Standard, compatible
with programming syntax of 8164A Lightwave
Interfaces: GPIB, RS232C,
Parallel Printer Interface (Centronics)
Measurement System, 8166A Lightwave Multichannel System, 8153A Lightwave Multimeter.
*for details please refer to Programming guide P/N 08164-91016
Agilent 81632A 81635A 81633A 81634A Power Sensor Modules (InGaAs) (InGaAs) dual (InGaAs) (InGaAs)
Wavelength Range 800 nm to 1650 nm 800 nm to 1700 nm
Power Range +10 dBm to -80 dBm +10 dBm to -90 dBm +10 dBm to -110 dBm
Uncertainty (accuracy) <±3% (1200 nm to 1630 nm) <±2.5% (1000 nm to 1630 nm) at reference conditions
Relative Uncertainty due to Polarization typ ±0.015 dB <±0.005 dB due to Spectral Ripple typ ±0.015 dB <±0.005 dB
Linearity (power) (CW +10 dBm to -60 dBm) (CW +10 dBm (CW +10 dBm at 23°C ±5°C <±0.02 dB ±20 pW to -70 dBm) to -90 dBm)
<±0.015 dB ±2 pW <±0.015 dB ±0.2 pW
Agilent 81623A 81624A 81625A Optical Heads
2)
(Ge, ø 5 mm) (InGaAs, ø 5 mm) (InGaAs, ø 5 mm)
Wavelength Range 750 nm to 1800 nm 800 nm to 1700 nm 850 nm to 1650 nm
Power Range +10 dBm to -80 dBm +10 dBm to -90 dBm +20 dBm to -80 dBm
Uncertainty (accuracy) <±2.2% <±2.2% <±2.5% at reference conditions (1000 nm to 1650 nm) (1000 nm to 1630 nm) (950 nm to 1630 nm)
Relative Uncertainty
due to Polarization ±0.005 dB ±0.005 dB
due to Spectral Ripple (typ. ±0.002 dB) (typ. ±0.002 dB)
Linearity (power) (CW +10 dBm to -60 dBm) (CW +10 dBm to -70 dBm) (CW +20 dBm to -60 dBm) at 23°C ±5°C <±0.025 dB ±100 pW <±0.02 dB ±5 pW <±0.02 dB ±100 pW
1)
For full specifications, and the test conditions, see the Technical Specifications p/n 5962-9321E
2)
All optical heads have to be operated with the single (81618A) or dual (81619A) Interface Module.
g
Agilent Standard Source Modules 81650A 81651A 81652A 81654A (Fabry-Perot Laser)
Center Wavelength 1310 nm 1550 nm 1550 nm/1625 nm 1310 nm/1550 nm
Output Power >0 dBm
Short term (15 min) <±0.005 dB CW power stability typ <±0.003 dB with coherence control active
Long term (24 h) typ ±0.03 dB CW power stability
CW power stability to back typ ±0.003 dB
reflection (RL 14 dB)
Agilent High Power Source Modules 81655A 81656A 81657A (Fabry-Perot Laser)
Center Wavelength 1310 nm ±15 nm 1550 nm ±15 nm 1310 nm/1550 nm ±15 nm
Output Power >+13 dBm
Short term (15 min) <±0.005 dB CW power stability typ <±0.003 dB with coherence control active
Long term (24 h) typ ±0.03 dB CW power stability
±15 nm ±15 nm ±15 nm ±15 nm
CW power stability to back typ ±0.003 dB
reflection (RL 14 dB)
Compact Tunable Laser Source Module 81689A
Wavelength Range 1525 nm to 1575 nm
Output Power +6 dBm
Power Stability ±0.03 dB
Signal to Source Spontaneous Emission Ratio (typ.) 39 dB/nm
Wavelength Repeatability ±0.05 nm
Wavelength Stability (typ., 24h) <±0.02 nm
h Bandwidth
High Bandwidth
Hi
High
Bandwidth
Connection to Test Devices
The 8163A Lightwave Multimeter supports a wide range of fiber connec­tors. For details please refer to the 8163A Configuration Guide. This gives information on the connector interfaces and bare fiber adapters for use with these modules, as well as the filter holders, filters, lenses and connector adapters required for the optical heads.
Ordering Information
The 8163A Mainframe has two slots for any combination of the modules listed in this document, or modules of the 8153A Lightwave Multimeter series.
Connector interfaces should also be ordered for each input and output, as well as any bare fiber adapters you require.
If you want to use optical heads, you also need an interface module 81618A (single) or 81619A (dual) and you may need filter holders, filters, lenses and connector adapters.
Agilent 8163A Lightwave Multimeter Stimulus Response Solution
“Working together
should be a standard.”
DWDM
DWDM
Loading...