Atec AEMC-SR651 User Manual

AC Current Probe Model SR651 (pdf) Rev. 03 10/03
Technical Assistance (800) 343-1391 www.aemc.com1of 4
AC Current Probe Model SR651
The Model SR651 is designed for use in industrial and utility environments. The unique ergonomic design allows it to easily clamp onto cables or small bus bars. It is built to the highest safety and performance standards including the CE Mark and is UL approved.
Excellent transformation and low phase shift, plus a broad frequency response, permit accurate measure­ments of current for power and power quality measurements. The high quality magnetic cores and uniform windings provide sensitivity for very low level current measurements, as well as measurements up to 1200A
AC.
The Model SR651 provides an accurate voltage output of 1mV/A. This voltage output enables instruments without current ranges to measure, display log currents through an AC voltage range or measure very low AC.

Features

Measurement range of
100mA to 1200A
AC
Large jaw opening accommodates
conductors up to two 500MCM conductors
Improved ergonomic design and
easy operation
Conforms to EN 61010, 600V Cat. III
safety standard
Low phase shift for power
measurements
Available with mAor mV
output signals
Designed for DMMs, recorders,
loggers, oscilloscopes, power and harmonic meters
CE Mark

Applications

Power quality measuring
Low industrial loads
Measuring around cable bundles
Power load monitoring
Waveform analysis
AC Current Probe Model SR651 (pdf) Rev. 03 10/03
Technical Assistance (800) 343-1391 www.aemc.com2of 4

Specifications

MODEL SR651
ELECTRICAL
Nominal Range 1000A Measurement Range 0.1 to 1200A Transformation Ratio Voltage output Output Signal 1mV/AAC/AAC (1VAC @ 1000A) Accuracy (1000A Range)
1 to 50A 3% ± 0.1A
50 to 200A 1.5% of Reading
200 to 1000A 0.75% of Reading
1000 to 1200A 0.5% of Reading
Phase Shift (1000A Range)
50 to 200A 1.5°
200 to 1000A 0.75°
1000 to 1200A 0.5°
Overload 1200A for 40 min ON, 20 min OFF Frequency Range 30Hz to 5kHz; current derating above 1kHz using the formula: 1000A x 1/F (in kHz) Load Impedance 100kmin Crest Factor 6 Working/Common
Mode Voltage:
600V Cat. III
Output Termination Jack
MECHANICAL
Operating Temperature -14° to 122°F (-10° to 50°C) Storage Temperature -4° to 158°F (-20° to 70°C) Operating Relative
Humidity
0 to 85% @ 35°C
Jaw Opening 2.25" (57mm) max Maximum Conductor Size 2.05" (52mm) Maximum Bus Bar Size One 1.95 x 0.19" (50 x 5mm) Dimensions 4.37 x 8.50 x 1.77" (111 x 216 x 45mm) Weight 1.21 lbs (550g) Polycarbonate Material Handles: Polycarbonate + ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
Electrical EN 61010-2-032 CE Mark Yes
Note: Reference conditions:
23 ± 3°K, 20 to 75% RH, 48 to 65Hz, external magnetic field < 40A/m, no DC component, no external current carr ying conductor, test sample centered. Load impedance 1Ω.