ATD Tools ATD-3441 User Manual

0 (0)

ATD-3441

VACUUM PUMP - 1.5 CFM SINGLE STAGE

As a specialized enterprise in making vacuum pumps, we are always devoting ourselves to satisfying users’ need of high-qualified products. We adopt the latest design and technique to make sure that our products use less energy, produce less noise and last long, but also are the best design for protecting the environment and emitting less pollution. Our excellent design and manufacturing will bring you more convenience.

1. Pump Use

ATD vacuum pumps are designed to obtain vacuum by pumping gas from sealed containers. They are suitable for use with R12, R22 and R134a air conditioning systems, as well as medical appliances, printing machinery and vacuum packing. They can be continuously used at 23°F (-5°C) to 140°F (60°C).

2. Features

Oil Anti-flow back Design

The gas inlet is specially designed to prevent the oil from flowing back, preventing the container being pumped as well as the hoses from becoming contaminated.

Environmental Design

The tank has separating devices at the exhaust port to prevent oil spraying and to reduce pollution.

Aluminum Alloy Casing

The ATD vacuum pump is manufactured with an aluminum alloy casing.

Because aluminum has good heat dissipation qualities, it will help to keep the pump running more efficiently for a longer period of time.

Overall Design

The electric components and the pump are designed to make the product compact and lighter.

Easy to start, Faster to pump

The starter design makes the ATD vacuum pump easy to start even in lower temperatures. This feature allows higher efficiency and faster pumping.

Low Noise and Vibration

An electrometric-coupling insert between the motor and module results in extremely quiet and smooth operation.

ATD Tools ATD-3441 User Manual

3. Product Illustration

4. User's Manual

·Examine the oil-level before using to make sure the oil-level is not lower than the oil-level line

in the sight glass. DO NOT RUN PUMP WITH LOW OIL LEVELS. Add oil to bring it up to the oil level line. This pump uses pump oil HFV-46 or equivalent.

·Connect the container to be pumped to the gas inlet. The hose should be short, sealed and free of dust, dirt and heavy condensation. Check for leaks before operating pump.

·Take off the exhaust cap, plug in the power supply and turn the switch to the on position.

·Unplug the vacuum pump, remove the connecting hoses and cover the exhaust cap and oil plug after using.

5. Cautions

·Don’t pump flammable, explosive or poisonous gases.

·Don’t pump gas that can corrode metals and exert chemical charges.

·Don’t pump gas containing any dust or moisture.

·The temperature of the pumped gas shouldn’t be over 173°F (80°C) and the room temperature should be around 23°F (-5°C) to 140°F (60°C).

·Don’t use vacuum pump as a compression pump.

Loading...