ATD-3441
VACUUM PUMP - 1.5 CFM SINGLE STAGE
As a specialized enterprise in making vacuum pumps, we are always devoting ourselves to
satisfying users’ need of high-qualified products. We adopt the latest design and technique to
make sure that our products use less energy, produce less noise and last long, but also are the
best design for protecting the environment and emitting less pollution. Our excellent design
and manufacturing will bring you more convenience.
1. Pump Use
ATD vacuum pumps are designed to obtain vacuum by pumping gas from sealed containers.
They are suitable for use with R12, R22 and R134a air conditioning systems, as well as
medical appliances, printing machinery and vacuum packing. They can be continuously used
°F (-5°C) to 140°F (60°C).
at 23
2. Features
Oil Anti-flow back Design
The gas inlet is specially designed to prevent the oil from flowing back, preventing the
container being pumped as well as the hoses from becoming contaminated.
Environmental Design
The tank has separating devices at the exhaust port to prevent oil spraying and to reduce
pollution.
Aluminum Alloy Casing
The ATD vacuum pump is man ufactured with an aluminum alloy casing.
Because aluminum has good heat dissipation qualities, it will help to keep the pump running
more efficiently for a longer period of time.
Overall Design
The electric components and the pump are designed to make the product compact and lighter.
Easy to start, Faster to pump
The starter design makes the ATD vacuum pump easy to start even in lower temperatures.
This feature allows higher efficiency and faster pumping.
Low Noise and Vibration
An electrometric-coupling insert between the motor and module results in extremely quiet and
smooth operation.
3. Product Illustration
4. User's Manual
·Examine the oil-level before using to make sure the oil-level is not lower than the oil-level line
in the sight glass. DO NOT RUN PUMP WITH LOW OIL LEVELS
the oil level line. This pump uses pump oil HFV-46 or equivalent.
·Connect the container to be pumped to the gas inlet. The hose shoul d be short, sealed and
free of dust, dirt and heavy condensation. Check for leaks before operating pump.
·Take off the exhaust cap, plug in the power supply and turn the switch to the on position.
·Unplug the vacuum pump, remove the connecting hoses and cover the exh aust cap and oil
plug after using.
. Add oil to bring it up to
5. Cautions
·Don’t pump flammable, explosive or poisonous gases.
·Don’t pump gas that can corrode metals and exert chemical charges.
·Don’t pump gas containing any dust or moisture.
· The temperature of the pumped gas shouldn’t be over 173
temperature should be around 23
·Don’t use vacuum pump as a compression pump.
°F (-5°C) to 140°F (60°C).
°F (80°C) and the room