ATC K, KT1, K1, K3 Instruction Manual

Applied Thermal Control Limited
Unit 1 Garden Court, Gee Road, Whitwick Business Park, Coalville, Leicestershire, LE67 4NB.
United Kingdom
T:+44 (0)1530 839998 – sales@app-therm.com – www.app-therm.com
KT1
STANDARD MODELS
INSTRUCTION MANUAL
Issue 3.2
KT1 series chillers – Installation and Operation manual
Issue 3.2 1
Contents
1.0
Introduction
2
Safety
3
1.1
Unpacking
4
1.2
1.3
Site requirements Warranty registration
5 6
2.0
Installation Voltage selection Coolant filling
7 7 8
3.0
Operation
9
4.0
Maintenance and service requirements
11
4.1
Troubleshooting
12
5.0
Return of goods procedure
13
6.0
Dimensions and performance
14
7.0
EC Declaration of Conformity
15
KT1 series chillers – Installation and Operation manual
Issue 3.2 2
1.0 Introduction
By selecting a K series chiller, you have invested in many years’ experience in the design
and manufacture of precision temperature control instrumentation.
ATC has built your K series chiller without compromise to meet the objectives of performance and reliability. Please read this manual carefully to ensure you understand the operation of the machine and how to use the unit safely and efficiently.
If you have any questions regarding installation or repair of this unit, please contact ATC direct.
Applied Thermal Control Limited Unit 1 Garden Court Gee Road Whitwick Business Park Coalville Leicestershire LE67 4NB United Kingdom
Tel: +44 (0) 1530 839998 e-mail: sales@app-therm.com
KT1 series chillers – Installation and Operation manual
Issue 3.2 3
Safety
For your safety we draw your attention to the following Warning and Caution statements throughout the manual. The safe operation of a KT series chiller always remains the responsibility of the operator.
Caution: Failure to comply with a Caution will invalidate product warranty and absolve
ATC from any liability, howsoever caused, and could result in permanent dam-
age to equipment.
Warning: Use of this equipment in any manner not specified by the manufacturer may
result in the protection provided by the equipment being impaired.
Warning: Failure to comply with a ‘Warning’ may result in personal injury or death. ATC
does not accept any liability for injury caused through use of this equipment.
Warning: No user serviceable parts.
Warning: Very hot surfaces, in excess of 100°C
Warning: Very cold surfaces and gases, lower than -40°C. Severe frostbite hazard.
Warning: Opening the refrigeration system may expose the operative to toxic and cor-
rosive compounds (HFC’s). Take protective measures including suitable eye protection.
Warning: Gases may exceed 300 psi (20 bar) during operation.
Warning: All refrigerants do not support combustion and are asphyxiating gases.
Warning: After switching off, the fan blades continue to rotate. Do not attempt service
whilst the blades are rotating.
Warning: All chillers contain water and electricity in close proximity. Always ensure the
unit is isolated before service. The KT1 has an on-off switch and four protec-
tive fuses. Never bypass these components.
Caution: Filling/topping up of the tank should only be undertaken with the unit
switched off, to prevent back-flooding of the fluid.
KT1 series chillers – Installation and Operation manual
Issue 3.2 4
Caution: The high integrity refrigeration system contains no user-serviceable parts.
Repair and service requires specialised knowledge and tools. Any unauthor­ised tampering with the refrigeration system automatically invalidates war­ranty.
1.1 Unpacking
Please check that both the packaging and the unit are undamaged. If there is any doubt, it is vital that you inform both ATC and the carrier before making a claim on the carrier. There are no hidden shipping bolts or other fixings. You should inspect the packaging for signs of transit damage before signing for the unit, and if possible unpack the unit before signing. Once you have signed for the goods, ATC cannot be held responsible for any transit damage subsequently found.
Remove the unit from its original packaging and ensure that there is no packaging left around the cooling ducts.
Please retain all packaging in the unlikely event that the chiller needs to be returned to
our local representatives.
Loading...