Asus 90S6KA0000C100UET User Manual

Page 1
ESC4000 Series
Conguration Guide
Page 2
E6314
First Edition V1
May 2011
Copyright © 2011 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
limited to the implied warranties or conditions of merchantability or tness for a particular purpose. In no event shall ASUS, its directors, ofcers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of prots, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product.
Specications and information contained in this manual ae furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the owners’ benet, without intent to infringe.
ii
Page 3
Contents
Revision history .......................................................................................... iii
Safety information ...................................................................................... iv
Chapter 1: Product introduction
1.1 Key features .................................................................................. 1-2
1.2 System overview .......................................................................... 1-4
1.3 Front panel features ..................................................................... 1-5
1.4 Rear panel features ...................................................................... 1-5
1.5 Systemspecications ................................................................. 1-6
Chapter 2: Components
2.1 Upgrading CPU and CPU heatsink ............................................. 2-2
2.2 Upgrading system memory ......................................................... 2-4
2.3 Upgrading hard disk drives ......................................................... 2-6
2.4 Installing ASUS Server Management Board .............................. 2-7
2.5 Installing ASUS PIKE RAID module............................................ 2-8
2.6 NVIDIA® Tesla™ GPU computing modules ................................ 2-9
2.7 OS support list ........................................................................... 2-10

Revision history

Revision Revision history Date
V1 First release of ESC4000 Series conguration guide May 2011
iii
Page 4

Safety information

Electrical Safety
Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged.
To prevent electrical shock hazard, disconnect the power cable from the
electrical outlet before relocating the system.
When adding or removing any additional devices to or from the system, contact
a qualied service technician or your dealer. Ensure that the power cables for
the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you service.
If the power supply is broken, do not try to x it by yourself. Contact a qualied
service technician or your dealer.
Operation Safety
Servicing of this product or units is to be performed by trained service personnel only.
Before operating the server, carefully read all the manuals included with the server package.
Before using the server, make sure all cables are correctly connected and the power cables are not damaged. If any damage is detected, contact your dealer as soon as possible.
To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry.
Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.
This product is equipped with a three-wire power cable and plug for the user’s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
CD-ROM Drive Safety Warning
CLASS 1 LASER PRODUCT
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system.
iv
Page 5
Chapter 1
This chapter describes the key features
of ESC4000 Series. It includes
the product overview and general
specications.
Product introduction
Page 6

1.1 Key features

The ASUS ESC4000 is a high density GPU server presented in a compact 2U
rack mount with support for dual Intel® Xeon® 5600 series processors, 18 DIMM
slots with up to 48GB/144GB memory and 4 double-wide NVIDIA
computing processors. It enables high-end professional applications such as
life/medical sciences, engineering and sciences, nancial modeling, EDA and visualization. The ESC4000 packs outstanding features, exible design and
versatile hardware, making it an ideal choice for intense parallel computing tasks.
Leading advanced system architecture
Features dual all-new Intel® Xeon® 5600 series processors with Intel® Core™
microarchitecture for signicant performance increases
Supports 18 DIMM slots and up to 48GB/144GB high scalability memory
for intense applications. DDR3 modules deliver higher speeds and more bandwidth with lower power consumption
Embeds up to four NVIDIA® Tesla™ M2050/M2070/M2090 GPUs on full PCI-E
Gen2 x16 slots with up to 2.66 teraops, doubling precision performance
The NVIDIA® Tesla™ M2090 GPU Computing Module is the world’s fastest parallel computing processor for HPC
8+1exibleexpansion
Eight PCI-E Gen2 x16 slot design supports up to four double-deck GPU
computing cards for professional graphics
Flex-E technology allows automatic switching between one PCI-E x16 and two
PCI-E x8 links
Additional PCI-E riser module compatible with both half-length/low-prole
PCI-E cards and ASUS PIKE series cards
®
Tesla™ GPU
Intelligent system fan control
Three independent smart system fans, two for GPU areas and one for general
motherboard cooling
Adjusts fan speed automatically according to system load to optimize cooling
and energy saving
Flexiblehighstoragecapacity
Designed with eight hard drive bays to support SAS or SATA drives
Optional ASUS PIKE meets the various requirements of RAID functionality
Chapter 1: Product introduction1-2
Page 7
Highreliability
1400W 80+ Gold power supply delivers reliable and highly efcient power
Hot-swap hard drive design allows downtime-free drive replacement
Remote control and management
Bundled ASMB4-iKVM module offers advanced server management
KVM-over internet provides OS-independent manageability
Ideal for remote ofce applications
ASUS ESC4000 Series 1-3
Page 8

1.2 System overview

9
3
4
5
11
10
12
12
6
7
8
2
1
Items Items
1. Hard disk drive bay 2. Hard disk drive
3. Computing module bracket 4. Computing module
5. Computing module airduct 6. CPU
7. CPU heatsink 8. ASMB4-iKVM controller card
9. DDR3 DIMM 10. PCI-E x16 riser card
11. Top cover 12. Rackmount rail kit
Chapter 1: Product introduction1-4
Page 9

1.3 Front panel features

1
2
HDD Access LED
ODD
HDD 1 HDD 5 HDD 2 HDD 6 HDD 3 HDD 7 HDD 4 HDD 8

1.4 Rear panel features

Resetbutton
Message LED
LAN1 LED LAN2 LED
USB ports
Location LED Location switch Power LED
Power
button
InniBandport(forESC4000/IBonly)
VGA port
Power cord connector
Redundant power supply
LAN port 3*
USB ports
4 Full-length
Expansionslots
LAN port 1
LAN port 2
Power cord connector
Redundant power supply
*The port is for ASUS ASMB4-iKVM controller card only.
Half-length/Low-prole Expansionslot
Serial port
4 Full-length
Expansionslots
ASUS ESC4000 Series 1-5
Page 10
1.5 Systemspecications
Model Name ESC4000 Series
2 x Socket LGA1366 Six/Quad-Core Intel® Xeon® X5600 Series
(130W/95W)
Processor / System Bus
Core Logic
Fan Speed
ASUS Features
Memory
ExpansionSlots
Storage
Control ASWM 2.0 Total Slots
Capacity
Memory Type
Memory Size
Total PCI/PCI-X/ PCI-E Slots
Slot Type
Additional Slot
SATA Controller
SAS Controller
Quad-Core Intel® Xeon® X5500 Series (95W) Quad-Core Intel® Xeon® E5500 Series (80W) Quad-Core Intel® Xeon® L5500 Series (60W/38W)
QPI 4.8 / 5.86 / 6.4 GT/s
Intel® 5520 IOH Intel® ICH10R I/O Controller NVIDIA® nForce® 200 x 2
√ 18 (3-channel per CPU, 3 DIMMs per channel) Maximum up to 144GB (RDIMM)
Maximum up to 48GB (UDIMM) DDR3 1333 / 1066 / 800 Reg DIMM / Unbuffered
DIMM with ECC
1GB, 2GB, 4GB and 8GB (RDIMM) 1GB, 2GB and 4GB (UDIMM)
9
Full-length
- 8 x PCI-E x16 (4 at Gen2 x16 Link or 8 at Gen2 x8 Link) (Slot 1, 3, 5, 7 auto switch to x8 Link if slot 2, 4, 6, 8 is occupied)
Half-length / Low-prole
- 1 x PCI-E x16 (Gen1 x4 Link) (PIKE SAS Card
for Storage Enhancement)
PIKE Riser Card
Intel® ICH10R:
- 6 x SATA2 300MB/s ports
- Intel® Matrix Storage (for Windows only)
- Supports software RAID 0, 1, 5 & 10
LSIMegaRAID(forLinux/Windows):
- Supports software RAID 0, 1 & 10
Optional:
ASUS PIKE 1068E 8-port SAS RAID card ASUS PIKE 1078 8-port SAS HW RAID card ASUS PIKE 6480 8-port SAS RAID card ASUS PIKE 2008 8-port SAS2 6G RAID card ASUS PIKE 2008/IMR 8-port SAS2 6G RAID card ASUS PIKE 2108 8-port SAS2 6G H/W RAID card
(continued on the next page)
Chapter 1: Product introduction1-6
Page 11
HDD Bays
AorSwillbe hot-swappable
Networking LAN Graphic VGA
AuxiliaryStorageDeviceBay (Floppy/OpticalDevice)
OnboardI/O
OS Support
Anti-virus Software
Out of Band
I = Internal
Management Solution
Remote Hardware
Software
Dimension(HHxWWxDD) NetWeightKg(CPU,DRAM&
HDDnotincluded)
Power Supply
Power Rating
Environment
8 x Hot-swap 3.5” SATAII/SAS HDD Bays
2 x Intel 82574L + 1 x Mgmt LAN Aspeed AST2050 / 8MB
1 x slim-type Optical Device Bay
(Options: No Device / DVD-RW)
1 x External Serial Port 3 x RJ-45 ports (1 for ASMB4-iKVM) 4 x USB 2.0 ports (Front x 2, Rear x 2) 1 x Internal A Type USB Port
1 x VGA port 1 x QSFP Port for Inniband QDR (@ DDR speed, for ESC4000/IB only)
Windows® Server 2008 R2 Windows® Server 2008 Enterprise 32 / 64-bit Windows® Server 2003 R2 Enterprise 32 / 64-bit RedHat® Enterprise Linux AS5.5 32 / 64-bit SuSE® Linux Enterprise Server 11 32 / 64-bit (Subject to change without any notice)
Optional Anti-virus Software CD
ASMB4-iKVM for KVM-over-IP support (Bundled)
ASUS ASWM 2.0 750mm x 444mm x 88mm (2U)
18 Kg
1400W (80+) 1+1 Redundant Power Supply (Default
with one Power Supply Module)
Input: 100—140/180—240 Vac, 12—9.5A/9.5A—7A, 50—60Hz Class 1
Operation temperature: 10°C–35°C / Non operation temperature: -40°C–70°C Non operation humidity: 20%–90% ( Non-
condensing)
*Specicationsaresubjecttochangewithoutnotice.
ASUS ESC4000 Series 1-7
Page 12
Chapter 1: Product introduction1-8
Page 13
Chapter 2
This chapter lists the key components and optional accessories for the server system.
Components
Page 14

2.1 Upgrading CPU and CPU heatsink

2
1
4
5
3
6
ASUS ESC4000 Series supports two Intel® LGA1366 Xeon® processors per Node.
We recommend to install CPUs with the same frequency.
Chapter 2: Components2-2
Page 15
Order P/N Description 90-S000U0BS0T
90-S000U08Z0T
90-S000U0BT0T
90-S000U08Y0T
90-S000U08X0T
90-S000U08W0T
90-S000U0BU0T
90-S000U0BV0T
90-S000U08V0T
90-S000U08U0T
90-S000U08T0T
90-S000U0BW0T
90-S000U0BX0T
90-S000U0BY0T
90-S000U0BZ0T
90-S000U0990T
90-S000U0C10T
90-S000U09A0T
90-S000U0C20T
90-S000U09Q0T
90-S000U09B0T
90-S000U09C0T
Six Core Intel Xeon X5690, 3.46GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Six Core Intel Xeon X5680, 3.33GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Six Core Intel Xeon X5675, 3.06GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Six Core Intel Xeon X5670, 2.93GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Six Core Intel Xeon X5660, 2.80GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Six Core Intel Xeon X5650, 2.66GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5649, 2.53GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5645, 2.40GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5640, 2.66GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5630, 2.53GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5620, 2.40GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5607, 2.26GHz, QPI 4.8GT/s, 8MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5606, 2.13GHz, QPI 4.8GT/s, 8MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon E5603, 1.60GHz, QPI 4.8GT/s, 4MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon X5687, 3.60GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon X5677, 3.46GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon X5672, 3.20GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon X5667, 3.06GHz, QPI 6.4GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon X5647, 2.93GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Six Core Intel Xeon L5640, 2.26GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon L5630, 2.13GHz, QPI 5.86GT/s, 12MB L2, Single Pack with 1U Heatsink
Quad Core Intel Xeon L5609, 1.86GHz, QPI 4.8GT/s, 12MB L2, Single Pack with 1U Heatsink
ASUS ESC4000 Series 2-3
Page 16

2.2 Upgrading system memory

1
2
3
4
5
DIMM_A3
DIMM_A2
DIMM_A1
DIMM_B3
DIMM_B2
13
14
11
10
12
DIMM_D3
DIMM_D2
DIMM_D1
DIMM_E3
DIMM_E2
6
DIMM_B115DIMM_E1
7
DIMM_C316DIMM_F3
8
DIMM_C217DIMM_F2
9
DIMM_C118DIMM_F1
1
2
3
4
5
6
7
8
12
13
14
15
16
17
18
11
10
9
The motherboard comes with eighteen (18) Double Data Rate 3 (DDR3) Dual Inline
Memory Modules (DIMM) sockets.
You may install 1 GB, 2 GB, 4 GB and 8 GB registered DDR3 DIMMs with ECC or 1GB, 2GB and 4GB unbuffered DDR3 DIMMs with ECC into the DIMM sockets using the memory congurations in this section.
Always install DIMMs with the same CAS latency. For optimum compatibility, it is recommended that you obtain memory modules from the same vendor.
For CPU1 conguraton, when installing only one DIMM, install it to the
orange slots labeled DIMM_A1, DIMM_B1, or DIMM_C1.
For CPU2 conguraton, when installing only one DIMM, install it to the
orange slots labeled DIMM_D1, DIMM_E1, or DIMM_F1.
Order P/N Description
90-S000I05K0T DDR3 1333 ECC REG 2G 240P SINGLE PACK 90-S000I05M0T DDR3 1333 ECC UNB 2G 240P SINGLE PACK 90-S000I0570T DDR3 1333 ECC UNB 4G 240P SINGLE PACK 90-S000I05H0T DDR3 1333 ECC REG 4G 240P SINGLE PACK 90-S000I05I0T DDR3 1066 ECC REG 8G 240P 4RANK SINGLE PACK
Chapter 2: Components2-4
Page 17
Memorypopulationtable
For UDIMM and Quad Ranks RDIMM:
CPU1Conguration
DIMM_A3 DIMM_A2 DIMM_A1 DIMM_B3 DIMM_B2 DIMM_B1 DIMM_C3 DIMM_C2 DIMM_C1
1 DIMM
2 DIMMs
3 DIMMs
4 DIMMs
5 DIMMs -- -- -- -- 6 DIMMs
CPU2Conguration
1 DIMM
2 DIMMs
3 DIMMs
4 DIMMs
5 DIMMs -- -- -- -- 6 DIMMs
-- -- -- -- -- -- -- --
-- -- -- -- -- -- --
-- -- -- -- -- --
-- -- -- -- --
-- -- --
DIMM_D2 DIMM_D1 DIMM_E3 DIMM_E2 DIMM_E1 DIMM_F3 DIMM_F2 DIMM_F1
DIMM_D3
--
--
--
--
-- --
-- -- -- -- -- -- --
-- -- -- -- -- --
-- -- -- -- --
-- -- -- --
--
ForRDIMM(SingleRank,DualRanks):
CPU1Conguration
DIMM_A3 DIMM_A2 DIMM_A1 DIMM_B3 DIMM_B2 DIMM_B1 DIMM_C3 DIMM_C2 DIMM_C1
1 DIMM
2 DIMMs
3 DIMMs
4 DIMMs
5 DIMMs
6 DIMMs
7 DIMMs 8 DIMMs 9 DIMMs
CPU2Conguration
1 DIMM
2 DIMMs
3 DIMMs
4 DIMMs
5 DIMMs
6 DIMMs
7 DIMMs 8 DIMMs 9 DIMMs
-- -- -- -- -- -- -- --
-- -- -- -- -- -- --
-- -- -- -- -- --
-- -- -- -- --
-- -- -- --
-- -- --
-- --
DIMM_D3 DIMM_D2 DIMM_D1 DIMM_E3 DIMM_E2 DIMM_E1 DIMM_F3 DIMM_F2 DIMM_F1
-- -- -- -- -- -- -- --
-- -- -- -- -- -- --
-- -- -- -- -- --
-- -- -- -- --
-- -- -- --
-- -- --
-- --
--
ASUS ESC4000 Series 2-5
Page 18

2.3 Upgrading hard disk drives

The system supports eight hot-swap SATAII/SAS hard disk drives.
We recommend that you install identical drives of the same model and capacity
for RAID conguration.
Order P/N Description
90-S000H65D1T SATA3 500G 7200rpm with tray (single pack) 90-S000H65C1T SATA3 750G 7200rpm with tray (single pack) 90-S000H65B1T SATA3 1TB 7200rpm with tray (single pack) 90-S000H64R0T SAS 6G 300G 15Krpm with tray (single pack) 90-S000H64S0T SAS 6G 450G 15Krpm with tray (single pack) 90-S000H64T0T SAS 6G 600G 15Krpm with tray (single pack)
Chapter 2: Components2-6
Page 19
2.4 Installing ASUS Server Management Board
ASUS Server Management Board is an Intelligent Platform Management Interface
(IPMI) 2.0-compliant board that allows users to monitor, control and manage a remote server from the local or central server in local area network (LAN).
ASUS Server Management Board
BaseboardManagementController(BMC) connector(14-pinBMC_FW1)
ASMB4-iKVM
Monitor the running status of major components via LAN or Serial Port, such
as CPU and memory utilization, storage capacity and networking transfer rate.
Advanced server management functions including “remote power on/off/reset”,
“remote control via SOL (Serial-over LAN)” and “remote SEL (system event log
reading when the system is out-of-band)”.
Support Dynamic Host Conguration Protocol (DHCP), which avoids
manually assigning IP address by setting DHCP mode to receive IP address automatically.
Use the LAN3 port for
server management.
LAN3 port
ASUS ESC4000 Series 2-7
Page 20

2.5 Installing ASUS PIKE RAID module

1
5
4
3
3
6
2
The ASUS PIKE RAID module allows users to create RAID function from SAS hard disk drives connected to the SAS connectors on the motherboard.
1. Firmly hold the riser card bracket, and then pull it up to detach it from the PCI Express x16 slot on the motherboard.
2. Align and insert the golden ngers of the PIKE SAS RAID card into the card
slot on the PIKE raiser card. Ensure the card is completely seated on the slot.
3. Remove the SATA/SAS cables from the onboard SATA connectors and connect the SATA/SAS cables to the SAS1–8 connectors on the PIKE riser
card.`
4. Connect the SGPIO2 cable (with a green label) to the SGPIO1 connector and the SGPIO3 cable (without a label) to the SGPIO2 connector on the PIKE
riser card.
5. Install the i Button*.
* PIKE 1078 module won’t function if the i Button is not installed.
6. Align the riser card bracket to the PCI Express x16 slot on the motherboard
and press the riser card bracket until the golden ngers completely t the slot
and the bracket aligns with the rear panel.
Order P/N Description
90-C1SE10-00UAY20Z PIKE 2008 8-port SAS 6G RAID Kit (RAID 0, 1, 1E) 90-C1SE15-00UAY00Z PIKE 2008/IMR 8-port SAS 6G RAID Kit (RAID 0, 1, 5) 90-C1SEF0-00UAY00Z PIKE 2008 8-port SAS 6G RAID Kit (RAID 0, 1, 5,6,10, 50, 60)
Chapter 2: Components2-8
Page 21
2.6 NVIDIA® Tesla™ GPU computing
1
2
11
10
9
8
3
4
5
6
7
modules
Follow the steps below to install the optional NVIDIA® Tesla™ GPU computing modules to the system.
Order P/N Description
90-S000R1E00T TESLA C2050 3GB GPU CARD Single Pack 90-S000R1F00T TESLA C2070 6GB GPU CARD Single Pack 90-S000R1G00T TESLA M2070 6GB GPU CARD Single Pack 90-S000R1H00T TESLA M2050 3GB GPU CARD Single Pack
ASUS ESC4000 Series 2-9
Page 22

2.7 OS support list

OS support list
Windows Server 2008 Enterprise Edition SP2 x86 Windows Server 2008 Enterprise Edition SP2 x64 Windows Server 2008 Standard Edition R2 x64 Windows 7 x86 Windows 7 x64 Red Hat Enterprise Linux AS 5.5 x86 Red Hat Enterprise Linux AS 5.5 x64 SuSE Linux Enterprise Server 11 SP1 x86 SuSE Linux Enterprise Server 11 SP1 x64 Cent OS 5.5 x86
Cent OS 5.5 x64
Chapter 2: Components2-10
Loading...