ASUS 1064E, 1068E User Manual

PIKE 1064E/1068E
LSISAS RAID card
User Guide
E3846
First Edition V1 June 2008
Copyright © 2008 ASUSTeK COMPUTER INC. All Rights Reserved.
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the owners’ benet, without intent to infringe.
ii

Contents

Contents ...................................................................................................... iii
About this guide ......................................................................................... iv
PIKE 1064E/1068E specications summary............................................. vi
Chapter 1: Product introduction
1.1 Welcome! ...................................................................................... 1-2
1.2 Package contents .........................................................................
1.3 Card layout ...................................................................................
1.4 System requirements ...................................................................
1.5 Card installation ...........................................................................
Chapter 2: RAID conguration
2.1 Setting up RAID ............................................................................ 2-2
2.1.1 RAID denitions ..............................................................
2.1.2 Installing hard disk drives ................................................
2.2 LSI Corporation MPT Setup Utility .............................................
2.2.1 Integrated Mirroring volume ............................................
2.2.2 Integrated Mirroring Enhanced volume ...........................
2.2.3 Integrated Striping (IS) volume .....................................
2.2.4 Managing Arrays ...........................................................
2.2.5
2.2.6 Global Properties ..........................................................
Viewing SAS topology ................................................... 2-17
1-2
1-3
1-3
1-4
2-2
2-2
2-3
2-4
2-8
2-10
2-12
2-18
Chapter 3: Driver installation
3.1 RAID driver installation ............................................................... 3-2
3.1.1 Creating a RAID driver disk ............................................
®
3.1.2 Windows
3.1.3 Red Hat
Server 2003 OS ............................................. 3-4
®
Enterprise Linux OS ........................................ 3-9
3.1.4 SUSE Linux Enterprise Server OS ................................
3-2
3-11
iii

About this guide

This user guide contains the information you need when installing and conguring
the server management board.
How this guide is organized
This guide contains the following parts:
Chapter 1: Product introduction
This chapter offers the PIKE 1064E/1068E SAS RAID card features and the new technologies it supports.
Chapter 2: RAID conguration
This chapter provides instructions on setting up, creating, and conguring
RAID sets using the available utilities.
Chapter 3: Driver installation
This chapter provides instructions for installing the RAID drivers on different operating systems.
Where to nd more information
Refer to the following sources for additional information and for product and software updates.
1. ASUS websites
The ASUS website provides updated information on ASUS hardware and software products. Refer to the ASUS contact information.
2. Optional documentation
Your product package may include optional documentation, such as warranty
yers, that may have been added by your dealer. These documents are not
part of the standard package.
iv
Conventions used in this guide
To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.
DANGER/WARNING: Information to prevent injury to yourself
when trying to complete a task.
CAUTION: Information to prevent damage to the components
when trying to complete a task.
IMPORTANT: Instructions that you MUST follow to complete a
task.
NOTE: Tips and additional information to help you complete a
task.
Typography
Bold text Indicates a menu or an item to select.
Italics
Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than sign means that you must press the enclosed key.
Example: <Enter> means that you must press the Enter or Return key.
<Key1+Key2+Key3> If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).
Example: <Ctrl+Alt+D>
Command Means that you must type the command exactly as shown,
then supply the required item or value enclosed in brackets.
Example: At the DOS prompt, type the command line: format a:
v
PIKE 1064E/1068E specications summary
Controller PIKE 1064E: LSISAS1064E
Interface ASUS PIKE interface
Ports PIKE 1064E: 4 ports
Support device SAS and SATA II devices
Data transfer rate SATA II and SAS 3 Gb/s per PHY
RAID level RAID0/RAID1/RAID1E
OS support* Windows® Server 2003/2000/XP/Vista
Form factor 6.44 in x 1.57 in (1U compatible)
* The exact OS support would base on the OS support list of the motherboard. ** Specications are subject to change without notice.
PIKE 1068E: LSISAS1068E
PIKE 1068E: 8 ports
Red Hat® Enterprise Linux 3/4/5 SUSE Linux Enterprise Server 8/9/10 LSI MegaRAID Storage Manager (MSM) for Windows®/ Linux operating systems
vi
This chapter offers the PIKE 1064E/1068E SAS RAID card features and the new technologies it supports.
Chapter 1: Product
1
introduction

1.1 Welcome!

Thank you for buying an ASUS® PIKE 1064E/1068E SAS RAID card!
The ASUS PIKE 1064E/1068E allows you to create RAID0, RAID1, and RAID1E set(s) from SAS hard disk drives connected to the SAS connectors on the motherboard.
Before you start installing the RAID card, check the items in your package with the list below.

1.2 Package contents

Check your package for the following items.
ASUS PIKE 1064E/1068E SAS RAID card
Support CD
User guide
If any of the above items is damaged or missing, contact your retailer.
1-2 Chapter 1: Product introduction

1.3 Card layout

The illustration below shows the major components of the RAID card.
3
122
1. ASUS PIKE interface-1: PCI-E x8
2. ASUS PIKE interface-2: 4-port SAS signal with SGPIO interface (PIKE 1064E) 8-port SAS signal with SGPIO interface (PIKE 1068E)*
3. SAS RAID card status LED (lights up and blinks to indicate that the card is working normally)
* The SGPIO interface is used for visibility into drive activity, failure and rebuild status, so that users could build high-performatnce and reliable storage systems. Refer to the motherboard manual for detailed information about using the SGPIO connectors on the motherboard.
For PIKE 1068E SAS RAID card, a heatsink is installed on the
LSISAS1068E controller.
1

1.4 System requirements

Before you install the PIKE 1064E/1068E SAS RAID card, check if the system meets the following requirements:
Workstation or server motherboard with a PIKE RAID card slot
SAS or SATA hard disk drives
Supporting operating system:
Windows® and Linux operating systems (refer to website for details)
Other requirement:
- Appropriate thermal solution
- Certied power supply module
ASUS PIKE 1064E/1068E 1-3

1.5 Card installation

Follow below instructions to install the RAID card on your motherboard.
1. Locate the PIKE RAID card slot on the motherboard.
2. Align the golden ngers of the RAID
card with the PIKE RAID card slot.
3. Insert the RAID card into the PIKE RAID card slot. Make sure it’s completely inserted into the PIKE RAID card slot.
Connect the SAS hard disk drives to SAS connectors 1-4 (red) on the motherboard when using a 4-port PIKE RAID card. The SAS connectors 5-8 (blue) function when using a 8-port PIKE RAID card.
1-4 Chapter 1: Product introduction
This chapter provides instructions on setting
up, creating, and conguring RAID sets using
the available utilities.
Chapter 2: RAID
conguration
2

2.1 Setting up RAID

The RAID card supports RAID 0, RAID 1 and RAID 1E set.
2.1.1 RAID denitions
RAID 0
(Data striping)
data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of at least two new identical hard disk drives is required for this setup.
RAID 1
(Data mirroring)
drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of
the data in the other drive. This RAID conguration provides data protection and
increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same
size or larger than the existing drive.
RAID 1E secondary (or alternate) copy stored on a different disk. You can use three or more
hard disk drives for this conguration.
(Enhanced RAID 1)
If you want to boot the system from a hard disk drive included in a created RAID
set, copy rst the RAID driver from the support CD to a oppy disk before you
install an operating system to the selected hard disk drive.
optimizes two identical hard disk drives to read and write
copies and maintains an identical image of data from one
has a striped layout with each stripe unit having a

2.1.2 Installing hard disk drives

The RAID card supports SAS for RAID set conguration. For optimal performance,
install identical drives of the same model and capacity when creating a disk array.
To install the SAS hard disks for RAID conguration:
1. Install the SAS hard disks into the drive bays following the instructions in the system user guide.
2. Connect a SAS signal cable to the signal connector at the back of each drive and to the SAS connector on the motherboard.
3. Connect a power cable to the power connector on each drive.
2-2 Chapter 2: RAID conguration

2.2 LSI Corporation MPT Setup Utility

The LSI Corporation MPT Setup Utility is an integrated RAID solution that allows you to create the following RAID set(s) from SAS hard disk drives supported by the LSI SAS 1064E/1068E controller:
RAID 1 (Integrated Mirroring)
RAID 1E (Integrated Mirroring Enhanced)
RAID 0 (Integrated Striping)
You may use disks of different sizes in IM and IME volumes; however, the size of the smallest disk determines the “logical” size of each member disk.
DO NOT combine Serial ATA and SAS disk drives in one volume.
The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference.
The adapter name shown on the setup screens differs according to the installed SAS RAID card.
Before requesting support from the ASUS Technical Support team, you have to take note of the MPTFW and MPTBIOS version for the SAS RAID
card. After entering the SAS conguration utility, you can see below screen
and identify the MPTFW and MPTBIOS version: MPTFW version: 1.24.00.00-IR MPTBIOS version: v6.20.00.00 (2007.12.04)
LSI Corp Cong Utility v6.20.00.00 (2007.12.04)
Adapter List Global Properties
Adapter PCI PCI PCI PCI FW Revision Status Boot BUS Dev Fnc Slot Order
SAS1064E 02 00 00 20 1.24.00.00-IR Enabled 0
Esc = Exit Menu F1/Shift+1 = Help Alt+N = Global Properties -/+ = Alter Boot Order Ins/Del = Alter Boot List
ASUS PIKE 1064E/1068E 2-3
Loading...
+ 29 hidden pages