Aspire NX75 User Manual

TCR settings: Press"T"and "+"
simultaneously to change TCR settings. Press “T” button to select coil material from Ni, Ti, SS, M1, M2, M3. Press “W” button to select between “PWR” (Power) and “TCR” (Temperature Control) under M1, M2, M3 mode. Press “+” and “-” buttons to change PWR or TCR numbers (note TCR numbers can be adjusted from
0.20‰ to 9.99‰) Note: ‰=×10
Language Selection: Pressing the fire
button while installing the battery will bring up the firmware version then you may select English and Chinese language. Press “+” or “-” button to select, fire button to confirm.
● The display will auto rotate for easy of use.
Customizable Firing Button Profiles (CFBP)
Customizable Firing Button Profiles (CFBP)
Intro:
The CFBP feature allows for heat ramp-up
(power curve) to be fine-tuned. This customization can be made with just a few clicks of the NX mod buttons. There is no need to connect to computer to program settings making this function very easy to use. Firing button profiles create extraordinary flavor with no limitations on tanks.
-3
Press W button to select VW,VV,Bypass, C1,C2
and C3. C1,C2,C3 are CFBP. Under CFBP, users can customize power curves to create their preferred taste. The graph above shows the CFBP curve when the mod been idle.
When the firing button is held down, the
screen will display the power curve you have preset. Users can set the wattage for each second if needed.
While in CFBP, Press W button for 1.5
seconds will bring you to CFBP interface. While in CFBP setting interface, press W or T button to set time, press “+” button to increase wattage, press “-” button to decrease wattage. To save settings simply press the fire button.
Charging
The NX75 has a new USB Type-C charging port, the maximum charging
current can reach up to 2A.
● Connect your NX75 mod to the charger
and the screen will show a flashing battery icon. When the battery charge reaches 4.2V or is fully charged, the mod will stop charging and the screen will remain off.
● The battery can not be replaced
while charging. Please unplug the USB cable before changing your battery.
● When the battery charge drops
below 0.5V or battery incorrectly installed the mod will stop charging.
● To accomplish 2A charge current,
the adaptor output should be
5V/2A.
Firmware Upgrade
● Download the driver software from Aspire website:
http://www.aspirecig.com/upgrade/
● Connect your NX75 to your PC.
The driver will detect your NX mod automatically.
● Click “OpenFile” to choose the
correct firmware file. Click “Update” to upgrade your NX mod.
● If it failed during the update
please repeat step 3 to
step 4.
process
Note:
SS under TC Mode only supports SS316L coils.
The mod supports passthrough charging. To lengthen the life of the mod, we do not recommend while charging (passthrough).
To learn more about your products and how to use,
www.aspirecig.com
please visit:
Designed and Manufactured By Eigate in China
Copyright 2016 Aspire. All Rights Reserved.
8765
vaping
Floating 510 connection
Fire button
“W” Button
“T” Button
0.86 inch OLED display
“-” Button
USB Type-C port
“+” Button
Battery compartment
NX75 mod User M anual
Specifications
Wattage Range: 1-75W Output Voltage Range: 0.00-8.50V Resistance Parameters: In both
3.5ohm (Wattage may be less than 75 watts when coil resistance exceeds 0.2-0.9ohm).
Continuous Fire Time can be adjusted from 5s to15s Charging Port: USB Type-C charging
port
Screen: OLED 0.86 inch Firmware update via USB Type-C port Dimensions: 22.5*36.8*75mm Battery: 3.7V single 18650 high rate
discharge battery
Temperature Control
Temperature Range (F): 200-600F Temperature Range (C): 100-315
Protection Features
● Automatic Cut Off
● Short Circuit Protection
● Low Resistance Protection
● Overheat Protection
● Over charge Protection
● Over Discharge Protection
1 2 3 4
Instructions
● The mod will automatically turn on
after installing battery, the screen will then display user’s previous settings, after 15 seconds of being idle the screen will turn off.
● Press the fire button 5 times within 2
seconds to either lock or unlock the device. while the mod was locked, press the fire button for 3 seconds will turn the system off. To turn the mod back on press the fire button 5 times rapidly.
● When the mod is on, press W button
to switch mode between VW,VV and Bypass modes. Press T button to select Ni200, Ti, SS316 M2, M3 manual modes).
or TCR (M1,
Press “+” to increase wattage,
or temperature “-” button to Press “+” or “-” button longer will the number faster.
● When the mod is on press the fire
button 3 times quickly to put the mod into or out of stealth mode, while in stealth mode the mod can still fire but the wattage or temperature settings cannot be adjusted.
While the mod is in TC mode
a new atomizer the mod will read
“New Atomizer? ” followed by
“YES+/NO-“ Select “YES+” and the mod will read the original coil resistance. Select “NO-“ and the mod will keep its previous coil resistance settings.
The NX75 will detect and lock coil
resistance automatically under TC mode. To ensure accuracy when first installing a new atomizer make sure the coil is at room temperature before attaching it to the mod.
To change temperature to Fahrenheit(F)
or to Celsius(C), press the “+”or “-” all the way to pass the temperature range, the temperature will switch over to Celsius or Fahrenheit automatically.
The preset continuous fire time is 10
seconds, after 10 seconds of continuous use, the mod will stop firing and the display will flash “10s”. Users then can adjust the fire time from 5s to 15s by pressing "+"/"-" button.
voltage
decrease.
change
attaching
button
either
Functions
Lock and Unlock buttons: Press
"W" and "+"simultaneously for 2 seconds to lock or unlock buttons. There will be a lock or unlock symbol in the upper right corner of the screen. When the buttons have been locked the mod can still fire, but the settings cannot be
Child Lock: Press "W" and "-"
simultaneously for 2 seconds to enter or exit Child lock mode. Press "+"or "-" button to select numbers, press fire button to confirm, the original pass word is"000", choose arrow symbol to reset. Users need input the pass word to lock or unlock.
Change Logo function: Press
"T" and "-" simultaneously for 2 seconds to enter or exit change logo settings. Press "+" or "-" to select letters, press fire button to confirm,"W" button to delete, and button "T" to select between lowercase and capital letters.
adjusted.
Loading...