05
L1 (W) L2 (W) L3 (<W) Total load (W)
HIG1944
3700 3700 5 7400
A
B
C
A (mm) B (mm) C (mm) D (mm) E (mm)
HIG1944 904 522 54 265 180
Rangehoods and exhaust fans shall be
installed in accordance with
manufacturers instructions.
For an overhead exhaust fan A>750 mm!
This appliance must be earthed
The electrical connection must comply with national and local regulations.
Connected load
A (>mm) B (mm) C (mm) D (>mm) E (>mm) F (>mm) G (>mm) H (>mm)
HIG1944
600 860 490 60 40 50 66 100
E
E/F
C
D
G
B
A
F
H
oven
Accessibility!
Gas connection
Important information
Pictograms used
Electrical connection
Installation instructions
Combination hob induction/gas
Au
The fitting of the appliance should only be carried out by a authorised person/licensed gasfitter. Please read the safety regulations.
See the data plate for information regarding the total gas consumption, gas type and gas pressure.
Preparations for installation
The gas connection must comply with national and local regulations.
The hotplate can be connected with rigid pipe as specified in
AS/NZS 5601.1current edition.
When the appliance is connected with a hose assembly,
the supply point shall be accessible with the appliance installed.
1/2” ISO 228 / 1/2" ISO 7-1
y
y
x
x
>60º C
<60º C
oven
Y:
metal
Gas supply valve
shall be accessible
X:
safety hose
Gas supply valve
shall be accessible
A
B
min.
B+D
C
E
D
Free space around appliance
A (>mm) C (>mm) D (>mm) E (> mm)
650 450 40 120
Placing sealing tape
Gas connection
C
05
05
1/2“ ISO 228
1/2“ ISO 7-1
PTFE tape
Worktop
C
GAS BURNER INJECTOR BURNER RATE GAS PRESSURE
BURNER (MJ/h) (kPa)
N.G. Wok (inner) 1.20 + 0.66 8.80 1.0
Wok (outer) 2.10 + 0.66 19.70
Electrical connection
3N 380-415V 50/60Hz - 3x 16A
3 phases - 1 neutral
Cross sectional area
415V 415V
415V
5x1.5mm
240V
240V
240V
ULPG Wok (inner) 0.63 + 0.40 8.50 2.75
Fitting of appliance regulator
for Natural gas or test point
adaptor for LPG.
Check and set the gas pressure
with appliance operating!
Wok (outer) 1.00 + 0.40 15.75
2N 380-415V 50/60Hz - 2x 16A
2 phases - 1 neutral
2
Cross sectional area
415V
4x1.5mm
240V
240V
2
1N 220-240V 50/60Hz - 1x 32A
1 phase - 1 neutral
Cross sectional area
240V
3x4mm
2
Consult the wiring diagrams on the underside of the appliance Make the required connections on the connecting block.
05
Ventilation
05
3
2
3
150
L
drawer
min.100 mm
L
1
min. 200 cm
2
05
Check that the connections are gastight.
The following appears on initial use:
Error code F04 -066 / No gas
- Check the gas supply
- Switch the appliance off and on using key button
- Re-ignite
- Repeat this procedure until the burner is lit
564197
564197
564197 / VER 2 / 13-02-2017