Ashly KLR-2000 Data Sheet

High Performance Amplifiers
KLR Series Two-Channel, High Performance Amplifiers
KLR-2000 | KLR-3200 | KLR-4000
Balanced inputs via 3-pin Euroblock and combo XLR/ ¼” TRS connectors
Switch mode power supply provides high efficiency and low weight
Forced air cooled (front in, rear out)
Removable dust filters
Front mounted attenuators
Ashly’s KLR-Series amplifiers are high-efficiency, lightweight, two­channel, high power amplifiers incorporating the latest technologies delivering quality and value for professional quality performance at an extremely affordable price. Whether your application is profes­sional audio or fixed performance installation, KLR amplifiers are op-
Front panel indicators for output level, clip/protect, and power on/off
Gain selectable switch for both chan­nels
KLR specifications
timized to provide reliable audio performance with sonic perfection.
Rack ears for permanent installation in a standard 2RU enclosure
Covering a power range from 1000 to 2000 watts per channel at 2 ohms (20Hz-20kHz, 1% THD), the KLR-2000, KLR-3200, and KLR-4000 are perfectly suited for a wide range of sound reinforcement. All three KLR amplifiers are optimized to deliver high levels of sustained power, extraordinary audio performance, and road-proven reliabil­ity into 2, 4, or 8 ohm loads and are housed in a a uniform, rugged 2RU chassis. Each KLR amplifier uses a state-of-the-art Switch Mode
Neutrik Speakon output connectors
3-position gain switch (1V, 32dB or 26dB sensitivity)
3-position mode switch (bridged, ste­reo or parallel mono)
Power Supply which assures you of flawless lows, punchy mids and pristine highs. The output topography of the KLR-2000 and KLR–3200 are Class-AB, while the KLR-4000 is a two-step Class-H design. KLR­Series protection circuits include: output over-current protection, DC output protection, chassis internal temperature monitoring, inrush limiting and a mains circuit breaker.
Front panel features include: individual input attenuators, signal, clip
3-position HPF switch (30Hz, 50Hz or off)
On/off limiter switch
Permanently attached power cord
Extensive protection circuitry
and protect LEDs, air inflow vents with removable dust filters, power switch and power LED. Rear panel features include: balanced in­puts via 3-pin Euroblock, combo XLR/ ¼” TRS connectors, Neutrik Speakon output connectors, 3-position gain switch (1V, 32dB or 26dB sensitivity), 3-position mode switch (bridged, stereo or parallel mono), 3-position HPF switch (30Hz, 50Hz or off), on/off limiter switch, air outflow vents and permanently attached power cord.
© 2010 | Ashly Audio, Inc. | 847 Holt Road | Webster | NY | 14580 | U.S.A. | www.ashly.com | info@ashly.com
* All features, specifications and graphical representations are subject to change or improvement without notice and may not represent the final product
KLR Series specifications
KLR-2000 | KLR-3200 | KLR-4000
KLR-2000 KLR-3200 KLR-4000
Rated Power Output Per Channel
Stereo Mode, both channels driven
8, 20 Hz - 20 kHz, 1% THD 350W 650W 850W
4Ω, 20 Hz - 20 kHz, 1% THD
2, 20 Hz - 20 kHz, 1% THD 1000W
Bridged Mono Mode
4Ω, 20 Hz - 20 kHz, 1% THD
Line Current Draw (all channels driven @4Ω)
Idle 0.99A 0.92A 1.05A
1/8th Power Pink Noise 9.7A 11.4A 14.0A
1/3 Power Sine Wave 14.9A 16.6A 19.8A
S/N (20 Hz-20 kHz, unweighted) >98dB >105dB >108dB
Thermal Dissipation (all channels driven @4)
Idle (BTU/hr) 164 136 171
1/8th Power Pink Noise (BTU/hr) 1876 2063 2489
1/3 Power Sine Wave (BTU/hr) 2880 3001 3516
Voltage Gain (rated output power @4) 31dB 33dB 36dB
Signal to Noise Ratio
(20Hz-20kHz, rated power @ 8 unweighted) >108 dB >109 dB >109 dB
Output Circuitry: Class AB Class AB 2 Step Class H
Weight 23.6 lbs (10.7kg) 24 lbs (10.9kg) 26.4 lbs (12kg)
Frequency Response 1W @ 8 20Hz-20kHz
(-3dB down point) +/- 0.3dB5Hz – 70kHz
Damping Factor – 100Hz @ rated power @8 >380
THD 20Hz-20kHz, 10dB below rated output @4<0.05%
Input Impedance 12 k, balanced
HPF (30Hz, 50Hz, Off), 12dB/Oct
Amplifier Protection Output Overcurent, DC Output, Chassis Temperature, Mains Breaker
Cooling Variable Speed Fan, Front to Rear Air Flow
Front Panel Indicators Prot/Clip, Signal, Power
Attenuators Per channel: front panel
Input Connectors, each channel 3- Pin Euroblock, XLR, ¼” TRS Phone Jack
Output connectors, each channel Speakon
Operating Temperature/Humidity Temperature: -10C - +40C / Humidity: 0% - 90%
Power Cable Connector Permanently Attached 3-Prong IEC
Dimensions 19” x 3.5” x 16” (482mm x 88mmx x407mm)
600W 1100W 1400W
1600W
2000W 3200W
2000W
4000W
SRA Series specifications
Notes: 0dBu = 0.775 VRMS
Ashly Audio, Inc. 847 Holt Road Webster, New York USA 14580-9103 P: 800-828-6308, +1-585-872-0010 F: +1-585-872-0739 www.ashly.com info@ashly.com
Specifications subject to change without prior notice. Latest information available at www.ashly.com. © 2010 Ashly Audio, Inc. Printed in U.S.A. 08/10
KLR Series Two-Channel Power Amplifiers July 2010
KLR-Series amplifiers are very efficient, lightweight high-power amplifiers incorporating the latest amplifier technologies.
Architect & Engineering Specs
KLR-2000
The two-channel power amplifier shall incorporate the latest amplifier technolo gy to deliver a minimum power of 1,000 Watts per channel into 2 Ohm loads, 600 Watts RMS per channel into 4 Ohm loads, or 350 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for paralle l mono and bridging modes. When switched into bridged-mono mode, the amplifier it shall deliver 2,000 Watts into a 4 Ohm load. The amplifier protection shall include o
current, DC output, chassis temperature, and a mains circuit-breaker.
Ohms). The Signal-to-Noise Ratio shall be greater than 108dB at rated power into 8 Ohms (unweighted). THD shall be less than
0.05% into 4 Ohms, 20Hz – 20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable s witch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outp uts shall be Neutrik Speakon connectors. L.E.D type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 24lbs/10.9kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 110 – 125VAC, 50 – 60Hz. The power amplifier shall be the Ashly KLR-2 000.
KLR-3200
The two-channel power amplifier shall incorporate the latest amplifier technolo gy to deliver a minimum power of 1,600 Watts per channel into 2 Ohm loads, 1,100 Watts RMS per channel into 4 Ohm loads, or 650 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for paralle l mono and bridging modes. When switched into bridged-mono mode, the amplifier it shall deliver 3,200 Watts into a 4 Ohm load. The amplifier protection shall include o
current, DC output, chassis temperature, and a mains circuit-breaker.
Ohms). The Signal-to-Noise Ratio shall be greater than 109dB at rated power into 8 Ohms (unweighted). THD shall be less than
0.05% into 4 Ohms, 20Hz – 20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable s witch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outp uts shall be Neutrik Speakon connectors. L.E.D type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 26.4lbs/12kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 110 – 125VAC, 50 – 60Hz. The power amplifier shall be the Ashly KLR-3 200.
KLR-4000
The two-channel power amplifier shall incorporate the latest amplifier technolo gy to deliver a minimum power of 2,000 Watts per channel into 2 Ohm loads, 1,400 Watts RMS per channel into 4 Ohm loads, or 850 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for paralle l mono and bridging modes. When switched into bridged-mono mode, the amplifier it shall deliver 4,000 Watts into a 4 Ohm load. The amplifier protection shall include o
current, DC output, chassis temperature, and a mains circuit-breaker.
Ohms). The Signal-to-Noise Ratio shall be greater than 109dB at rated power into 8 Ohms (unweighted). THD shall be less than
0.05% into 4 Ohms, 20Hz – 20kHz and 10dB below rated power. The amplifier shall have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable s witch on the rear panel. The inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outp uts shall be Neutrik Speakon connectors. L.E.D type indicators shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel mounted, removable dust filters. The power amplifier shall weigh 26.7lbs/12.1kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power requirement shall be 110 – 125VAC, 50 – 60Hz. The power amplifier shall be the Ashly KLR-4 000.
Ashly Audio, Inc 847 Holt Road Webster, New York USA 14580-9103 800-828-6308, +1-585-872-0010 KLR A&E_1a.pdf
utput over-
Frequency response shall be 20Hz to 20kHz (1W @ 8
utput over-
Frequency response shall be 20Hz to 20kHz (1W @ 8
utput over-
Frequency response shall be 20Hz to 20kHz (1W @ 8
www.ashly.com to download KLR series data sheets
Visit
Loading...