Ashley AFS7500 User Manual

Owner’s Operation and Instruction Manual
C
S
S
U
C
O
M
P
N
Y
U
N
I
T
E
D
S
T
A
T
E
S
S
T
O
V
E
SAFETY NOTICE: If this heater is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re offi cials about restrictions and installation requirements in your area.
MODEL: AFS7500
SAFETY TESTED TO UL 1482 and ULC-S627
US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE
WASHINGTON STATE APPROVED
MOBILE HOME APPROVED (U.S. ONLY)
CAUTION! Read All Instructions Carefully Before Starting The Installation
or Operating This Heater.
Improper Installation Could Void
SAFETY NOTICE: If this heater is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re offi cials about restrictions and installation requirements in your area.
Your Warranty!
SAVE THESE INSTRUCTIONS
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU
TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
United States Stove Company
227 Industrial Park Road
P.O. Box 151
South Pittsburg, TN 37380
851881
CONGRATULATIONS!
You’ve purchased a heater from North America’s oldest manufacturer of wood burning products.
By heating with wood you’re helping to CONSERVE ENERGY!
Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one
tree each year. Future generations will thank you.
The instructions pertaining to the installation of your wood stove comply with UL-1482 and ULC-S627 standards.
Combustible : Wood
Colors : Metallic Black
Flue Pipe Diameter : 6” (152.5mm)
Flue Pipe Type: (Standard Single Wall or Double Wall): Black or Blued Steel 2100°F (650°C)
Minimum Chimney Hieght : 12’ (3.7m)
Maximum Log Length : 21” (533.5mm)
Dimensions
Overall :
Depth x Width x Height :
Combustion Chamber :
Width x Depth :
Volume : Cubic Feet: 3.11 ft³ (.0881m³)
Door Opening : Width x Height: 16” x 8” (406.5mm x 203mm)
Pyroceramic Glass Door : (Viewing) Width x Height: 13
Weight (lbs): 415 lbs (188kg)
1
/
29
” x 27” x 31
2
3
/
4
22
x 21” (578mm x 533mm)
13
/
16
x 8
3
/
8
(351mm x 213mm)
3
/
4
(749mm x 686mm x 806mm)
OPTIONAL ACCESSORIES
DESCRIPTION PART #
Outside Air Intake Kit 50FAK
CAUTIONS:
• HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
• DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
• DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
• DO NOT BURN WASTES, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
• ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
2 Ussc
WARRANTY INFORMATION CARD
Name__________________________________________ Telephone #: (_____)_____________
City____________________________________________ State_______ Zip_________________
Email Address __________________________________________________________________
Model # of Unit________________________________ Serial #___________________________
Fuel Type:
Place of Purchase (Retailer)______________________________________________________
City____________________________________________ State_______ Zip_________________
If internet purchase, please list website address___________________________________
Date of Purchase _______________________________________________________________
Reason for Purchase: Alternative Heat Main Heat Source
Decoration Cost Other _________________________
What was the determining factor for purchasing your new appliance?_______
I have read the owner’s manual that accompanies this unit and fully understand the:
Installation
Wood Coal Pellet Gas Other _________________________

Operation  and Maintenance  of my new appliance.
Print Name Signature Date
Please attach a copy of your purchase receipt.
Warranty not valid without a Proof of Purchase.
Warranty information must be received within 30 days of original purchase.
Detach this page from this manual, fold in half with this page to the inside and tape together. Apply a stamp and mail to the address provided. You may use an enve­lope if you choose.
You may register online by going to www.usstove.com
All information submitted will be kept strictly con dential. Information provided will not be sold for advertising purposes.
CUT HERE CUT HERE
Ussc 3
Contact information will be used solely for the purpose of product noti cations.
Fold Here Fold Here
Fold Here

PLACE
STAMP
HERE
United States Stove Company P.O. Box 151 South Pittsburg, TN 37380
4 Ussc
CUT HERE CUT HERE
Tools and Materials Needed For Installation
You will need a drill with a 1/8” bit to install sheet metal screws into connector pipe. A 5/16” socket/wrench or screw driver to install pedestal trim, room air defl ector, and blower assembly described below. A 1/2” socket/wrench to install fl ue collar. A non-combustible fl oor protector as specifi ed in this manual. All chimney and chimney connector components required for your particular chimney installation. For mobile homes, see page 13.
Assembly
Flue Collar Assembly:
1. Mount the fl ue collar to the top of the unit as shown using the (3) tabs
provided in the parts box.
Firebrick Confi guration:
1. Replace the Firebrick as shown in the illustration below.
5/16-18 x 1-1/2 bolts, (3) washers, and (3) weld
Side view of fl ue collar
mount to heater top
Brick Confi guration
5/16-18 x 1-1/2 BOLT
HEATER TOP
WELD TAB
Ussc 5
BLOWER ASSEMBLY INSTRUCTIONS
THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION.
Step 1.
Fix the assembly to the back of the stove with the screws provided.
THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE.
DO NOT ROUTE THE SUPPLY CORD NEAR OR ACROSS HOT SURFACES!
PEDESTAL TRIM ASSEMBLY
Assemble trim pieces as shown with the screws provided in the parts bag. Washers may not be necessary.
After trim assembly, attach to the pedestal base at the location shown using the screws provided.
6 Ussc
INSTALLATION
SAFETY NOTICE
• IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
• CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA.
• USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
• KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
• NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE STOVE.
• IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN. CALL THE FIRE DEPARTMENT.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
• A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED.
POSITIONING THE STOVE
It is very important to position the wood stove as close as possible to the chimney, and in an area that will favor the most effi cient heat distribution possible throughout the house. The stove must therefore be installed in the room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by the installation of a blower.
The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur.
A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of fi re or fail to respect required clearances.
Ussc 7
FLOOR PROTECTOR
Your wood stove should be placed on a 1 inch, non-combustible surface with a k factor of 0.84. For multiple layers, add R-values of each layer to determine the overall R-value. The R value for the required board is 1.2. If there is a horizontal section of chimney connector, the fl oor protector should go under it and 2 inches beyond each side
Convert specifi cation to R-value: k-factor is given with a required thickness (T) in inches: R=1/k x T C-factor is given: R=1/C
Example: If the fl oor protector is 4” brick with a C-factor of 1.25 over 1/8” mineral board with a “k” factor of 0.29 the total R-value of the system is: 4” brick C=1.25, R=1/1.25=0.8 1/8” mineral board K=0.29, R=1/0.29 x 0.125=0.431 Total R = Rbrick + Rmineral = 0.8 + 0.431 = 1.231 Total R is greater than 1.2, the system is acceptable.
The fl oor protector should exceed the stove as follows:
Model Front Sides Rear
AFS7500
- Canadian installations require 8” (203mm)
26”
(660mm)8”(203mm)
6”
(152mm)
8 Ussc
Loading...
+ 16 hidden pages